Co-flow jets application for occupant targeted ventilation: Focus on thermal comfort and air quality

被引:1
|
作者
Zhou, Bin [1 ]
Li, Zhe [2 ]
Yang, Bin [2 ]
Wang, Faming [3 ]
Ai, Zhengtao [4 ]
Melikov, Arsen [5 ]
机构
[1] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, Xian 710055, Peoples R China
[2] Tianjin Chengjian Univ, Sch Energy & Safety Engn, Tianjin 300384, Peoples R China
[3] Katholieke Univ Leuven, Dept Biosyst, B-3001 Leuven, Belgium
[4] Hunan Univ, Coll Civil Engn, Dept Bldg Environm & Energy, Changsha 410082, Peoples R China
[5] Tech Univ Denmark, Int Ctr Indoor Environm & Energy, Dept Civil Engn, DK-2800 Lyngby, Denmark
关键词
Occupant targeted ventilation; Co-flow jet velocity; Turbulence intensity; Equivalent frequency; Air quality; Abbreviations; Nomenclature; PERSONALIZED VENTILATION; PERFORMANCE; SYSTEM; HOT;
D O I
10.1016/j.buildenv.2024.112086
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Co-flow air jets can be used in occupant-targeted ventilation, such as personalized ventilation, stratum ventilation, aiming at improving air quality in the breathing zone of occupants. However, these have not been studied sufficiently. The velocity field and cleanness of co-flow jets comprising inner jet of clean air encircled by outer jet of room air were studied under isothermal conditions by physical measurements and CFD simulations at numerous combinations of initial diameter and velocity of the inner and outer jets appropriate for practical application. The co-flow jet had a lower axial velocity decay along the jet direction than that of the single jet. The magnitude (turbulence intensity) and frequency of the velocity fluctuations in co-flow jets were lower compared to those in a single jet. The results revealed that with regard to thermal comfort co-flow jets may provide more cooling compared to single jets, especially when supplied toward to the user. The level of cleanness depended on the initial velocity of the inner and outer jets as well as their diameters. The air on the jet axis of the co-flow was up to 40 % cleaner compared to the single jet. The increased area ratio of outer nozzle to inner nozzle from 1.0 to 3.0 improved the cleanness of the air by at least 10% to the distance from 8 to 14 initial diameters compared to a single jet. The co-flow jet with velocity ratio of 1.5 had longest concentration core length, Lu, (up to 6 initial diameters to the inner jet) with clean air. The results can be used for design of occupant targeted ventilation.
引用
收藏
页数:24
相关论文
共 50 条
  • [31] Effect of sinusoidal splitter on mixing performance of co-flow jets of hydrogen and air inside dual-combustor ramjet
    Sun, Chuan
    Rayeni, Nima Sharifi
    Moghimihanjani, Mehrafarin
    Moradi, R.
    Li, Zhixiong
    Acta Astronautica, 2021, 180 : 211 - 217
  • [32] Influence of sinusoidal shock generator on mixing performance of hydrogen and air co-flow jets in dual-combustor ramjet
    Rostamian, MohammadKazem
    Maddah, Soroush
    Rostamiyan, Yasser
    ACTA ASTRONAUTICA, 2022, 195 : 109 - 117
  • [33] Mixing efficiency of hydrogen and air co-flow jets via wedge shock generator in dual-combustor ramjet
    Jiang, Yu
    Abu-Hamdeh, Nidal H.
    Bantan, Rashad A. R.
    Moradi, R.
    AEROSPACE SCIENCE AND TECHNOLOGY, 2021, 116
  • [34] Experimental study for comparison of thermal comfort and air age between two combined ventilation systems with chilled ceiling considering occupant density
    Nayyef, Dhuha Radhi
    Mahdi, Ala'a Abbas
    HEAT TRANSFER, 2023, 52 (05) : 3557 - 3581
  • [35] Association of Perceived Thermal Comfort and Air Quality with Building- and Occupant-Related Characteristics and Environmental Parameters in Sweden
    Psomas, Theofanis
    Teli, Despoina
    Donovan, Adam O'
    Kolias, Pavlos
    Langer, Sarka
    ENERGIES, 2024, 17 (06)
  • [36] Application of an occupant voting system for continuous occupant feedback on thermal and indoor air quality-Case studies in office spaces
    Khan, Donya Sheikh
    Kolarik, Jakub
    Weitzmann, Peter
    ENERGY AND BUILDINGS, 2021, 251
  • [37] Statistical analysis of natural and mechanical ventilation performance in improving indoor air quality, thermal comfort, and perceived air quality in a healthcare facility
    Gholampour, Marzieh
    Taghipour, Malihe
    Tahavvor, Alireza
    Jafari, Saeed
    INTERNATIONAL JOURNAL OF VENTILATION, 2024,
  • [38] Study on Thermal Comfort and Indoor Air Quality in the Classroom with System Air-conditioner and Ventilation System for Cooling Loads
    Noh, Kwang-Chul
    Jang, Jae-Soo
    Oh, Myung-Do
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2006, 30 (01) : 57 - 66
  • [39] Thermal comfort and indoor air quality in rooms with integrated personalized ventilation and under-floor air distribution systems
    Li, Ruixin
    Sekhar, S. C.
    Melikov, A. K.
    HVAC&R RESEARCH, 2011, 17 (05): : 829 - 846
  • [40] The Effect of Flow Rate of a Short Sleeve Air Ventilation Garment on Torso Thermal Comfort in a Moderate Environment
    Mengmeng Zhao
    Faming Wang
    Chuansi Gao
    Zhaoli Wang
    Jun Li
    Fibers and Polymers, 2022, 23 : 546 - 553