Co-flow jets application for occupant targeted ventilation: Focus on thermal comfort and air quality

被引:1
|
作者
Zhou, Bin [1 ]
Li, Zhe [2 ]
Yang, Bin [2 ]
Wang, Faming [3 ]
Ai, Zhengtao [4 ]
Melikov, Arsen [5 ]
机构
[1] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, Xian 710055, Peoples R China
[2] Tianjin Chengjian Univ, Sch Energy & Safety Engn, Tianjin 300384, Peoples R China
[3] Katholieke Univ Leuven, Dept Biosyst, B-3001 Leuven, Belgium
[4] Hunan Univ, Coll Civil Engn, Dept Bldg Environm & Energy, Changsha 410082, Peoples R China
[5] Tech Univ Denmark, Int Ctr Indoor Environm & Energy, Dept Civil Engn, DK-2800 Lyngby, Denmark
关键词
Occupant targeted ventilation; Co-flow jet velocity; Turbulence intensity; Equivalent frequency; Air quality; Abbreviations; Nomenclature; PERSONALIZED VENTILATION; PERFORMANCE; SYSTEM; HOT;
D O I
10.1016/j.buildenv.2024.112086
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Co-flow air jets can be used in occupant-targeted ventilation, such as personalized ventilation, stratum ventilation, aiming at improving air quality in the breathing zone of occupants. However, these have not been studied sufficiently. The velocity field and cleanness of co-flow jets comprising inner jet of clean air encircled by outer jet of room air were studied under isothermal conditions by physical measurements and CFD simulations at numerous combinations of initial diameter and velocity of the inner and outer jets appropriate for practical application. The co-flow jet had a lower axial velocity decay along the jet direction than that of the single jet. The magnitude (turbulence intensity) and frequency of the velocity fluctuations in co-flow jets were lower compared to those in a single jet. The results revealed that with regard to thermal comfort co-flow jets may provide more cooling compared to single jets, especially when supplied toward to the user. The level of cleanness depended on the initial velocity of the inner and outer jets as well as their diameters. The air on the jet axis of the co-flow was up to 40 % cleaner compared to the single jet. The increased area ratio of outer nozzle to inner nozzle from 1.0 to 3.0 improved the cleanness of the air by at least 10% to the distance from 8 to 14 initial diameters compared to a single jet. The co-flow jet with velocity ratio of 1.5 had longest concentration core length, Lu, (up to 6 initial diameters to the inner jet) with clean air. The results can be used for design of occupant targeted ventilation.
引用
收藏
页数:24
相关论文
共 50 条
  • [41] The Effect of Flow Rate of a Short Sleeve Air Ventilation Garment on Torso Thermal Comfort in a Moderate Environment
    Zhao, Mengmeng
    Wang, Faming
    Gao, Chuansi
    Wang, Zhaoli
    Li, Jun
    FIBERS AND POLYMERS, 2022, 23 (02) : 546 - 553
  • [42] GAS-FIRED HEATERS AND VENTILATION SYSTEM IMPROVE INDOOR AIR-QUALITY AND THERMAL COMFORT
    LIENHART, TG
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1994, 36 (03): : 47 - 49
  • [43] Numerical investigation of indoor thermal comfort and air quality for an office equipped with corner impinging jet ventilation
    Ameen, Arman
    Cehlin, Mathias
    Karimipanah, Taghi
    ADVANCES IN BUILDING ENERGY RESEARCH, 2023, 17 (05) : 578 - 604
  • [44] Hybrid Ventilation System and Soft-Sensors for Maintaining Indoor Air Quality and Thermal Comfort in Buildings
    Vadamalraj, Nivetha
    Zingre, Kishor
    Seshadhri, Subathra
    Arjunan, Pandarasamy
    Srinivasan, Seshadhri
    ATMOSPHERE, 2020, 11 (01)
  • [45] A review of integrated radiant heating/cooling with ventilation systems- Thermal comfort and indoor air quality
    Zhang, Chen
    Pomianowski, Michal
    Heiselberg, Per Kvols
    Yu, Tao
    ENERGY AND BUILDINGS, 2020, 223
  • [46] Computational study of hydrogen and air co-flow jets mixing in dual-combustor ramjet in presence of ramp shock generator
    Rostamian, MohammadKazem
    Maddah, Soroush
    Rostamiyan, Yasser
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART G-JOURNAL OF AEROSPACE ENGINEERING, 2023, 237 (07) : 1511 - 1519
  • [47] Temporal evolution of auto-ignition of ethylene and methane jets propagating into a turbulent hot air co-flow vitiated with NOx
    Eitel, Felix
    Pareja, Jhon
    Johchi, Ayane
    Boehm, Benjamin
    Geyer, Dirk
    Dreizler, Andreas
    COMBUSTION AND FLAME, 2017, 177 : 193 - 206
  • [48] Indoor air quality and thermal comfort in the lecture room with 4-way cassette air-conditioner and ventilation system
    Noh, KC
    Jang, JS
    Oh, MD
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 472 - 477
  • [49] Energy consumption, indoor thermal comfort and air quality in a commercial office with retrofitted heat, ventilation and air conditioning (HVAC) system
    Che, Wen Wei
    Tso, Chi Yan
    Sun, Li
    Ip, Danny Y. K.
    Lee, Harry
    Chao, Christopher Y. H.
    Lau, Alexis K. H.
    ENERGY AND BUILDINGS, 2019, 201 : 202 - 215
  • [50] IMPROVING INDOOR AIR QUALITY AND THERMAL COMFORT USING A TOTAL HEAT EXCHANGER VENTILATION SYSTEM FOR AN OFFICE BUILDING
    Chang, Linlan
    Permana, Indra
    Wang, Fujen
    Prasetyo, Bowo Yuli
    THERMAL SCIENCE, 2024, 28 (6A): : 4531 - 4544