This paper is dedicated to research of impinging jet (IJV) air distribution method. This system provides the desired indoor climate in office buildings. This paper describes the experimental requirements and boundary conditions for the CFD simulation and experiment in the climate chamber. The necessary modelling scenarios were developed to review the operation of the ventilation system according to different climatic conditions (winter, summer), human positions in the room and the shape of the supply duct. It is concluded that the shape of the air opening has little effect on the contaminant and heat removal effectiveness, 114%-122% and 1.12-1.16 respectively. At the same time, there is a large impact on the air exchange effectiveness (0.74-0.91). It was experimentally noted that in terms of contaminant removal and air exchange effectiveness, the circular opening provides better results. The human position depends on the supply temperature and flow velocity. By analyzing different scenarios, it was determined that the minimum acceptable distance to maintain thermal comfort within the standard requirements from the supply outlet is 1.7 m. As the distance from the air opening increases, the vertical air temperature difference at the height of 0.1-1.1 m decreases more than 2 times - from 1.9 K/m to 0.7 K/m. It is concluded that impinging jet ventilation has a great potential for use in office spaces both in winter and summer scenarios. This system significantly improves thermal comfort and indoor air quality. Applying impinging jet ventilation (IJV), limitations and peculiarities of the system such as supply air velocity, temperature and shape of the air duct must be carefully evaluated. (c) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Impact of impinging jet ventilation on thermal comfort and indoor air quality in office buildings
    Staveckis, Arturs
    Borodinecs, Anatolijs
    Energy and Buildings, 2021, 235
  • [2] Numerical investigation of indoor thermal comfort and air quality for an office equipped with corner impinging jet ventilation
    Ameen, Arman
    Cehlin, Mathias
    Karimipanah, Taghi
    ADVANCES IN BUILDING ENERGY RESEARCH, 2023, 17 (05) : 578 - 604
  • [3] Energy saving, indoor thermal comfort and indoor air quality evaluation of an office environment using corner impinging jet ventilation
    Ameen, Arman
    Cehlin, Mathias
    Yamasawa, Haruna
    Kobayashi, Tomohiro
    Karimipanah, Taghi
    DEVELOPMENTS IN THE BUILT ENVIRONMENT, 2023, 15
  • [4] Ventilation and indoor air quality in office buildings
    Pan, YQ
    Long, WD
    Fan, CY
    INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 225 - 229
  • [5] Thermal Comfort and Indoor Air Quality of Task Ambient Air Conditioning in Modern Office Buildings
    Zheng, Guozhong
    Jing, Youyin
    Huang, Hongxia
    Ma, Puzhao
    2009 INTERNATIONAL CONFERENCE ON INFORMATION MANAGEMENT, INNOVATION MANAGEMENT AND INDUSTRIAL ENGINEERING, VOL 2, PROCEEDINGS, 2009, : 533 - +
  • [6] Improving thermal comfort and indoor air quality through minimal interventions in office buildings
    Khatami, Narguess
    Hashemi, Arman
    8TH INTERNATIONAL CONFERENCE ON SUSTAINABILITY IN ENERGY AND BUILDINGS, SEB-16, 2017, 111 : 181 - 190
  • [7] Thermal and air quality comfort in the Hungarian office buildings
    Kajtár, L
    Erdösi, I
    Bakó-Biró, Z
    PROCEEDINGS OF THE SECOND NSF INTERNATIONAL CONFERENCE ON INDOOR AIR HEALTH: TRENDS AND ADVANCES IN RISK ASSESSMENT AND MANAGEMENT, 2001, : 270 - 278
  • [8] Assessment of Thermal Comfort and Air Quality of Room Conditions by Impinging Jet Ventilation Integrated with Ductless Personalized Ventilation
    Yang, Bin
    Liu, Pengju
    Liu, Yihang
    Jin, Dacheng
    Wang, Faming
    SUSTAINABILITY, 2022, 14 (19)
  • [9] Indoor Air Quality and Thermal Comfort in School Buildings
    Senitkova, Ingrid Juhasova
    WORLD MULTIDISCIPLINARY EARTH SCIENCES SYMPOSIUM (WMESS 2017), 2017, 95
  • [10] Numerical study on thermal stratification for impinging jet ventilation system in office buildings
    Hu, Jun
    Kang, Yanming
    Yu, Jia
    Zhong, Ke
    Building and Environment, 2021, 196