Nuclear Chloride Ion-Selective Fluorescent Probe and Its Biological Applications

被引:0
|
作者
Lee, Jongwon [1 ]
Shin, Injae [1 ]
机构
[1] Yonsei Univ, Dept Chem, Seoul 03722, South Korea
来源
ACS SENSORS | 2024年 / 9卷 / 08期
基金
新加坡国家研究基金会;
关键词
chloride ion; fluorescent protein; fluorescentprobe; biosensor; nucleus targeting; cellimaging; SMALL-MOLECULE; CELL-DEATH; MECHANISM; TRANSPORTERS; INDICATORS; APOPTOSIS; CHANNELS; IDENTIFICATION; TRAFFICKING; PROTEINS;
D O I
10.1021/acssensors.4c00868
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Owing to the biological significance of Cl- in cells, several chemical fluorescent probes and biosensors have been constructed to monitor this anion in the cytosol and subcellular organelles. However, a fluorescent probe for the selective detection of nuclear Cl- has not been described thus far. In the current study, we developed the first nuclear Cl--selective biosensor, Cl-YFP-NLS, whose fluorescence was effectively quenched by this anion, and demonstrated that it is an efficient and powerful tool for determining the levels of nuclear Cl-. The results of cell studies using Cl-YFP-NLS as the probe suggested that the level of Cl- in the nucleus is lower than that in the cytosol. In addition, Cl-YFP-NLS along with lysosomal (Lyso-MQAE) and mitochondrial Cl--selective fluorescent probes (Mito-MQAE) were utilized to determine the effects of various substances on the levels of Cl- in subcellular organelles. The results showed that lysosomotropic agents decrease the lysosomal Cl- concentration and increase the levels of mitochondrial and nuclear Cl-. Also, observations suggested that substances capable of inducing mitochondrial outer membrane permeabilization without inducing lysosomal membrane permeabilization increase mitochondrial and nuclear Cl- concentrations but they do not affect the level of lysosomal Cl-. Moreover, a substance directly disrupting nuclear pore complexes increased the level of nuclear Cl- and did not change the levels of lysosomal and mitochondrial Cl-. Finally, nucleus-affecting substances that cause deoxyribonucleic acid damage and activate p53 and Bax increased the levels of mitochondrial and nuclear Cl- without influencing the level of lysosomal Cl-.
引用
收藏
页码:4028 / 4036
页数:9
相关论文
共 50 条
  • [41] Napthalimide-based fluorescent probe for selective and sensitive sensing of formaldehyde and biological applications
    Nasirian, Azam
    Tikum, Anjong Florence
    Fortibui, Maxine Mambo
    Lee, Sohyun
    Kim, Jinheung
    DYES AND PIGMENTS, 2021, 188
  • [42] AN IMPROVED LIQUID ION-EXCHANGER FOR CHLORIDE ION-SELECTIVE MICROELECTRODES
    BAUMGARTEN, CM
    AMERICAN JOURNAL OF PHYSIOLOGY, 1981, 241 (05): : C258 - C263
  • [43] ENZYMES AND ION-SELECTIVE ELECTRODES - INNOVATIONS AND APPLICATIONS
    HUSSEIN, WR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1977, 173 (MAR20): : 74 - 74
  • [44] CHLORIDE ION-SELECTIVE MICROELECTRODES - AN IMPROVED ION-EXCHANGE RESIN
    BAUMGARTEN, CM
    BIOPHYSICAL JOURNAL, 1981, 33 (02) : A187 - A187
  • [45] A highly selective fluorescent probe for hydrogen peroxide and its applications in living cells
    Zhuang, Zhiyuan
    Yang, Qian
    Zhang, Zhanming
    Zhang, Qilong
    Zheng, Gengxiu
    Zhan, Fuxu
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2017, 344 : 8 - 14
  • [46] Nanoparticles of Fluorescent Conjugated Polymers: Novel Ion-Selective Optodes
    Klucinska, Katarzyna
    Stelmach, Emilia
    Kisiel, Anna
    Maksymiuk, Krzysztof
    Michalska, Agata
    ANALYTICAL CHEMISTRY, 2016, 88 (11) : 5644 - 5648
  • [47] Ion-selective electrodes for determining cephazolin in biological media
    Kulapina O.I.
    Baraguzina V.V.
    Skoblikova N.V.
    Pharmaceutical Chemistry Journal, 2008, 42 (8) : 481 - 484
  • [48] INTERFERENCE OF ORTHODIHYDROXYAROMATIC COMPOUNDS ON CHLORIDE ANALYSIS USING THE CHLORIDE ION-SELECTIVE ELECTRODE
    SAURETIGNAZI, G
    BEGUIN, C
    BARRELLE, M
    ANALUSIS, 1994, 22 (03) : 152 - 154
  • [49] INTERFERENCE OF HUMIC SUBSTANCES ON CHLORIDE ANALYSIS USING THE CHLORIDE ION-SELECTIVE ELECTRODE
    SIKORA, FJ
    STEVENSON, FJ
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 1987, 51 (04) : 924 - 929
  • [50] A TEFLON-GRAPHITE ION-SELECTIVE PROBE WITH INTEGRATED ELECTRONICS
    MELLOR, TJ
    HASKARD, M
    MULCAHY, DE
    ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1982, 15 (19): : 1549 - 1555