Nuclear Chloride Ion-Selective Fluorescent Probe and Its Biological Applications

被引:0
|
作者
Lee, Jongwon [1 ]
Shin, Injae [1 ]
机构
[1] Yonsei Univ, Dept Chem, Seoul 03722, South Korea
来源
ACS SENSORS | 2024年 / 9卷 / 08期
基金
新加坡国家研究基金会;
关键词
chloride ion; fluorescent protein; fluorescentprobe; biosensor; nucleus targeting; cellimaging; SMALL-MOLECULE; CELL-DEATH; MECHANISM; TRANSPORTERS; INDICATORS; APOPTOSIS; CHANNELS; IDENTIFICATION; TRAFFICKING; PROTEINS;
D O I
10.1021/acssensors.4c00868
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Owing to the biological significance of Cl- in cells, several chemical fluorescent probes and biosensors have been constructed to monitor this anion in the cytosol and subcellular organelles. However, a fluorescent probe for the selective detection of nuclear Cl- has not been described thus far. In the current study, we developed the first nuclear Cl--selective biosensor, Cl-YFP-NLS, whose fluorescence was effectively quenched by this anion, and demonstrated that it is an efficient and powerful tool for determining the levels of nuclear Cl-. The results of cell studies using Cl-YFP-NLS as the probe suggested that the level of Cl- in the nucleus is lower than that in the cytosol. In addition, Cl-YFP-NLS along with lysosomal (Lyso-MQAE) and mitochondrial Cl--selective fluorescent probes (Mito-MQAE) were utilized to determine the effects of various substances on the levels of Cl- in subcellular organelles. The results showed that lysosomotropic agents decrease the lysosomal Cl- concentration and increase the levels of mitochondrial and nuclear Cl-. Also, observations suggested that substances capable of inducing mitochondrial outer membrane permeabilization without inducing lysosomal membrane permeabilization increase mitochondrial and nuclear Cl- concentrations but they do not affect the level of lysosomal Cl-. Moreover, a substance directly disrupting nuclear pore complexes increased the level of nuclear Cl- and did not change the levels of lysosomal and mitochondrial Cl-. Finally, nucleus-affecting substances that cause deoxyribonucleic acid damage and activate p53 and Bax increased the levels of mitochondrial and nuclear Cl- without influencing the level of lysosomal Cl-.
引用
收藏
页码:4028 / 4036
页数:9
相关论文
共 50 条
  • [21] A chloride ion-selective boron nitride nanotube
    Won, Chang Y.
    Aluru, N. R.
    CHEMICAL PHYSICS LETTERS, 2009, 478 (4-6) : 185 - 190
  • [22] Mercury ion-selective fluorescent probe based on indazole fused rhodamine and cell imaging application
    Du, Bingxin
    Li, Qi
    Huang, Kun
    Wang, Qing
    Liang, Lijuan
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2023, 436
  • [23] ION-SELECTIVE ELECTRODES - THEIR APPLICATIONS AND LIMITATIONS
    HANSEN, EH
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1975, 35 : 52 - 52
  • [24] Selective fluorescent labeling of cellular proteins and its biological applications
    Choi, Joo Hee
    Kim, Sooin
    Kang, On-Yu
    Choi, Seong Yun
    Hyun, Ji Young
    Lee, Hyun Soo
    Shin, Injae
    CHEMICAL SOCIETY REVIEWS, 2024, 53 (19) : 9446 - 9489
  • [25] THEORY AND APPLICATIONS OF ION-SELECTIVE ELECTRODES
    KORYTA, J
    ANALYTICA CHIMICA ACTA, 1972, 61 (03) : 329 - +
  • [26] MIANSERIN ION-SELECTIVE MEMBRANE-ELECTRODE AND ITS PHARMACEUTICAL APPLICATIONS
    BUNACIU, AA
    IONESCU, MS
    STEFAN, RI
    IOAN, I
    ABOULENEIN, HY
    ANALYTICAL LETTERS, 1994, 27 (09) : 1647 - 1658
  • [27] A HIGHLY SELECTIVE NEAR-INFRARED FLUORESCENT PROBE FOR THE DETECTION OF DIPEPTIDYL PEPTIDASE IV AND ITS BIOLOGICAL APPLICATIONS
    Zou, Li-wei
    Qiang, Xing-Kai
    Wang, Dandan
    Ge, Guang-Bo
    Yang, Ling
    DRUG METABOLISM AND PHARMACOKINETICS, 2017, 32 (01) : S70 - S70
  • [28] A ratiometric fluorescent probe for ferric ion based on a 2,2′-bithiazole derivative and its biological applications
    Geng, Jiao
    Liu, Yuan
    Li, Jianhui
    Yin, Gui
    Huang, Wei
    Wang, Ruiyong
    Quan, Yiwu
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 222 : 612 - 617
  • [29] Colorimetric calcium probe with comparison to an ion-selective optode
    Huang ManLing
    Xie, Xiaojiang
    Zhu, Changyou
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [30] Colorimetric Calcium Probe with Comparison to an Ion-Selective Optode
    Zhu, Changyou
    Huang, Manling
    Lan, Jialing
    Chung, Lung Wa
    Li, Xin
    Xie, Xiaojiang
    ACS OMEGA, 2018, 3 (10): : 12476 - 12481