Nuclear Chloride Ion-Selective Fluorescent Probe and Its Biological Applications

被引:0
|
作者
Lee, Jongwon [1 ]
Shin, Injae [1 ]
机构
[1] Yonsei Univ, Dept Chem, Seoul 03722, South Korea
来源
ACS SENSORS | 2024年 / 9卷 / 08期
基金
新加坡国家研究基金会;
关键词
chloride ion; fluorescent protein; fluorescentprobe; biosensor; nucleus targeting; cellimaging; SMALL-MOLECULE; CELL-DEATH; MECHANISM; TRANSPORTERS; INDICATORS; APOPTOSIS; CHANNELS; IDENTIFICATION; TRAFFICKING; PROTEINS;
D O I
10.1021/acssensors.4c00868
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Owing to the biological significance of Cl- in cells, several chemical fluorescent probes and biosensors have been constructed to monitor this anion in the cytosol and subcellular organelles. However, a fluorescent probe for the selective detection of nuclear Cl- has not been described thus far. In the current study, we developed the first nuclear Cl--selective biosensor, Cl-YFP-NLS, whose fluorescence was effectively quenched by this anion, and demonstrated that it is an efficient and powerful tool for determining the levels of nuclear Cl-. The results of cell studies using Cl-YFP-NLS as the probe suggested that the level of Cl- in the nucleus is lower than that in the cytosol. In addition, Cl-YFP-NLS along with lysosomal (Lyso-MQAE) and mitochondrial Cl--selective fluorescent probes (Mito-MQAE) were utilized to determine the effects of various substances on the levels of Cl- in subcellular organelles. The results showed that lysosomotropic agents decrease the lysosomal Cl- concentration and increase the levels of mitochondrial and nuclear Cl-. Also, observations suggested that substances capable of inducing mitochondrial outer membrane permeabilization without inducing lysosomal membrane permeabilization increase mitochondrial and nuclear Cl- concentrations but they do not affect the level of lysosomal Cl-. Moreover, a substance directly disrupting nuclear pore complexes increased the level of nuclear Cl- and did not change the levels of lysosomal and mitochondrial Cl-. Finally, nucleus-affecting substances that cause deoxyribonucleic acid damage and activate p53 and Bax increased the levels of mitochondrial and nuclear Cl- without influencing the level of lysosomal Cl-.
引用
收藏
页码:4028 / 4036
页数:9
相关论文
共 50 条
  • [31] Comparison Between Fluorescent Probe and Ion-Selective Electrode Methods for Intracellular pH Determination in Leuconostoc mesenteroides
    Duried Alwazeer
    Christophe Riondet
    Rémy Cachon
    Current Microbiology, 2018, 75 : 1493 - 1497
  • [32] Comparison Between Fluorescent Probe and Ion-Selective Electrode Methods for Intracellular pH Determination in Leuconostoc mesenteroides
    Alwazeer, Duried
    Riondet, Christophe
    Cachon, Remy
    CURRENT MICROBIOLOGY, 2018, 75 (11) : 1493 - 1497
  • [33] POTENTIOMETRIC DETERMINATION OF CHLORIDE IN PULPING LIQUORS WITH A CHLORIDE ION-SELECTIVE ELECTRODE
    PAPP, J
    SVENSK PAPPERSTIDNING-NORDISK CELLULOSA, 1972, 75 (16): : 677 - &
  • [34] FLUORIDE AND CHLORIDE DETERMINATION IN CHEESE WITH ION-SELECTIVE ELECTRODES
    GONZALEZ, MA
    ALLER, AJ
    PARDO, R
    BARRADO, E
    DEBAN, L
    ELECTROANALYSIS, 1991, 3 (4-5) : 439 - 442
  • [35] A Study on Chloride Ion-selective Electrode Transient Potentiometry
    Shi, Sheng-Hua
    Guo, Yan-Li
    Suo, Zhi-Rong
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao/ Chemical Journal of Chinese Universities, 2001, 22 (04):
  • [36] A study on chloride ion-selective electrode transient potentiometry
    Shi, SH
    Guo, YL
    Suo, ZR
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2001, 22 (04): : 556 - 559
  • [37] CHLORIDE INTERFERENCE IN CUPRIC ION-SELECTIVE ELECTRODE MEASUREMENTS
    WESTALL, JC
    MOREL, FMM
    HUME, DN
    ANALYTICAL CHEMISTRY, 1979, 51 (11) : 1792 - 1798
  • [38] DIRECT MEASUREMENT OF CHLORIDE IN SWEAT WITH AN ION-SELECTIVE ELECTRODE
    SZABO, L
    KENNY, MA
    LEE, W
    CLINICAL CHEMISTRY, 1973, 19 (07) : 727 - 730
  • [39] ION-SELECTIVE ELECTRODE METHOD FOR DETERMINATION OF CHLORIDE IN MILK
    SWEETSUR, AW
    ANALYST, 1974, 99 (1183) : 690 - 692
  • [40] ONLINE MEASUREMENT OF TRACE CHLORIDE BY ION-SELECTIVE ELECTRODE
    WEST, SJ
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1979, 126 (08) : C382 - C382