A virtual anti-scatter grid for multi-energy photon counting detector systems

被引:0
|
作者
Purisha, Zenith [1 ,2 ]
Winkler, Alexander [3 ,4 ]
Emzir, Muhammad [1 ,5 ]
Hostettler, Roland [1 ,6 ]
Luukka, Panja [3 ]
Sarkka, Simo [1 ]
机构
[1] Aalto Univ, Dept Elect Engn & Automat, Aalto, Finland
[2] Univ Gadjah Mada, Dept Math, Yogyakarta, Indonesia
[3] Detect Technol Plc, Espoo, Finland
[4] Univ Helsinki, Helsinki Inst Phys, Helsinki, Finland
[5] King Fahd Univ Petr & Minerals, Dept Control & Instrumentat Engn, Dhahran, Saudi Arabia
[6] Uppsala Univ, Dept Engn Sci, Uppsala, Sweden
基金
芬兰科学院;
关键词
virtual; anti-scatter; grids; multi-energy; photon; counting; X-RAY TOMOGRAPHY; STATISTICAL INVERSION; GENERAL FRAMEWORK; CT; GAMMA; BNCT; CONVERGENCE; RADIOGRAPHS;
D O I
10.1088/1402-4896/ad7ce1
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Photon-counting (PC) systems are the next technological generation of medical computed tomography (CT) imaging and is being worked on by all major system providers. CT devices that are based on PC detectors enable multi-energy data collection. The information-content of this data can be used to obtain more detailed patient data, which improves the quality of reconstructions, compared to conventional detector systems. However, PC CT systems are subject to radiation scatter as just as any other imaging systems is. Conventionally anti-scatter grids (ASG) are used to reduce the scatter effect. These are however an imperfect solution, especially for PC detectors. In this work, a software-based scatter correction method, thus a virtual ASG is proposed. The method is tailoring a new statistical model in the measurement space and combining it with the statistical inversion method called Markov chain Monte Carlo (MCMC). The method can recover the measurement data from dense projections. We present the method on simulated data of a single photon emission computed tomography (SPECT) problem for which only under-sampled data is available. However, our approach can in principle be generalised to CT, PC-CT, Positron emission tomography (PET), radiotherapy, or even digital radiography problems. The results show that the proposed model performs similarly as physical ASGs and for cases where ASGs are not possible. The model further offers a significant improvement in the quality of the reconstruction image compared to the image reconstruction from original under-sampled data.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Effect of the anti-scatter grid and target/filters in full-field digital mammography
    Chakraborty, DP
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 878 - 885
  • [42] Compton scatter tomography with photon-counting detector: a preliminary study
    Wang, Kai
    Cheng, Haitao
    Chen, Xi
    Mou, Xuanqin
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [43] Feasibility of Deep-Learning Based Synthetic Anti-Scatter Grid for Chest Radiographs
    Hamdan, S.
    Hoerner, M. R.
    Grizzard, K. T.
    Benyakoub, A.
    Mustafa, A. A.
    MEDICAL PHYSICS, 2024, 51 (10) : 7761 - 7761
  • [44] Optimal Virtual Monoenergetic Photon Energy (keV) for Photon-Counting-Detector Computed Tomography Angiography
    Dunning, Chelsea A. S.
    Rajendran, Kishore
    Inoue, Akitoshi
    Rajiah, Prabhakar
    Weber, Nikkole
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Leng, Shuai
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2023, 47 (04) : 569 - 575
  • [45] Quantitative assessment of areal bone mineral density using multi-energy localizer radiographs from photon-counting detector CT
    Jasper, Soren
    Swicklik, Joseph
    Baffour, Francis
    Ferrero, Andrea
    El Sadaney, Ahmed O.
    Shanblatt, Elisabeth
    Nowak, Tristan
    Mccollough, Cynthia
    Rajendran, Kishore
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (22):
  • [46] Determination of Optimal Image Type and Lowest Detectable Concentration for Iodine Detection on a Photon Counting Detector Based Multi-Energy CT System
    Zhou, Wei
    Schornak, Rachel
    Michalak, Gregory
    Weaver, Jayse
    Abdurakhimova, Dilbar
    Ferrero, Andrea
    Fetterly, Kenneth A.
    McCollough, Cynthia H.
    Leng, Shuai
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [47] The Application of Multi-Energy in Smart Grid
    Zhang, Bo
    Song, Bin
    Wang, Sunan
    INTERNATIONAL CONFERENCE ON FRONTIERS OF ENVIRONMENT, ENERGY AND BIOSCIENCE (ICFEEB 2013), 2013, : 663 - 669
  • [48] Perturbation-Based Quality Surrogate for Scatter Estimation and Parameter Optimization in Anti-Scatter Grid (ASG)-CBCT
    Ruan, D.
    Bayat, F.
    Altunbas, C.
    MEDICAL PHYSICS, 2022, 49 (06) : E174 - E175
  • [49] Focused anti-scatter grid for background reduction in x-ray fluorescence tomography
    Larsson, Jakob C.
    Shaker, Kian
    Hertz, Hans M.
    OPTICS LETTERS, 2018, 43 (11) : 2591 - 2594
  • [50] A Practical Model for the Energy Response Function of Photon Counting Detector Systems with Anti-Charge Sharing Logic
    Ji, X.
    Feng, M.
    Zhang, R.
    Chen, G.
    Li, K.
    MEDICAL PHYSICS, 2019, 46 (06) : E302 - E302