A virtual anti-scatter grid for multi-energy photon counting detector systems

被引:0
|
作者
Purisha, Zenith [1 ,2 ]
Winkler, Alexander [3 ,4 ]
Emzir, Muhammad [1 ,5 ]
Hostettler, Roland [1 ,6 ]
Luukka, Panja [3 ]
Sarkka, Simo [1 ]
机构
[1] Aalto Univ, Dept Elect Engn & Automat, Aalto, Finland
[2] Univ Gadjah Mada, Dept Math, Yogyakarta, Indonesia
[3] Detect Technol Plc, Espoo, Finland
[4] Univ Helsinki, Helsinki Inst Phys, Helsinki, Finland
[5] King Fahd Univ Petr & Minerals, Dept Control & Instrumentat Engn, Dhahran, Saudi Arabia
[6] Uppsala Univ, Dept Engn Sci, Uppsala, Sweden
基金
芬兰科学院;
关键词
virtual; anti-scatter; grids; multi-energy; photon; counting; X-RAY TOMOGRAPHY; STATISTICAL INVERSION; GENERAL FRAMEWORK; CT; GAMMA; BNCT; CONVERGENCE; RADIOGRAPHS;
D O I
10.1088/1402-4896/ad7ce1
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Photon-counting (PC) systems are the next technological generation of medical computed tomography (CT) imaging and is being worked on by all major system providers. CT devices that are based on PC detectors enable multi-energy data collection. The information-content of this data can be used to obtain more detailed patient data, which improves the quality of reconstructions, compared to conventional detector systems. However, PC CT systems are subject to radiation scatter as just as any other imaging systems is. Conventionally anti-scatter grids (ASG) are used to reduce the scatter effect. These are however an imperfect solution, especially for PC detectors. In this work, a software-based scatter correction method, thus a virtual ASG is proposed. The method is tailoring a new statistical model in the measurement space and combining it with the statistical inversion method called Markov chain Monte Carlo (MCMC). The method can recover the measurement data from dense projections. We present the method on simulated data of a single photon emission computed tomography (SPECT) problem for which only under-sampled data is available. However, our approach can in principle be generalised to CT, PC-CT, Positron emission tomography (PET), radiotherapy, or even digital radiography problems. The results show that the proposed model performs similarly as physical ASGs and for cases where ASGs are not possible. The model further offers a significant improvement in the quality of the reconstruction image compared to the image reconstruction from original under-sampled data.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Coupling the use of anti-scatter grid with analytical scatter estimation in cone beam CT
    Rinkel, J.
    Gerfault, L.
    Esteve, F.
    Dinten, J. -M.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [22] Feasibility study of portable multi-energy computed tomography with photon-counting detector for preclinical and clinical applications
    Lee, Chang-Lae
    Hong, Key Jo
    Kim, Namwoo
    Han, Kwanhee
    Kim, Dongkyu
    Jung, Hoe-Su
    Lee, Sangmin
    Park, Junyoung
    Lee, Kyoung-Yong
    Lee, Jee Eun
    Choi, Yuna
    Cho, Minkook
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [23] Quantitative material characterization from multi-energy photon counting CT
    Alessio, Adam M.
    MacDonald, Lawrence R.
    MEDICAL PHYSICS, 2013, 40 (03)
  • [24] Investigating the Replacement of the Physical Anti-scatter Grid with Digital Image Processing
    Tromans, Christopher E.
    Diffey, Jennifer
    Brady, Michael
    DIGITAL MAMMOGRAPHY, 2010, 6136 : 205 - +
  • [25] An inherent anti-scatter detector for megavoltage x-ray imaging
    Teymurazyan, A.
    Pang, G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (05): : 1479 - 1493
  • [26] MONTE CARLO PREDICTIONS OF ANTI-SCATTER GRID PERFORMANCE IN NEUTRON RADIOGRAPHY
    PORTER, CR
    ROBINSON, AH
    MATERIALS EVALUATION, 1970, 28 (09) : A28 - &
  • [27] Dual harmonic anti-scatter grid artefact removal for digital radiography
    Ostojic, Vladimir S.
    Starcevic, Dorde S.
    Petrovic, Vladimir S.
    2017 25TH TELECOMMUNICATION FORUM (TELFOR), 2017, : 326 - 329
  • [28] Multi-energy CT imaging for large patients using dual-source photon-counting detector CT
    Tao, Shengzhen
    Marsh, Jeffrey F.
    Tao, Ashley
    Michalak, Greg J.
    Rajendran, Kishore
    McCollough, Cynthia H.
    Leng, Shuai
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (17):
  • [29] Characterization of scatter radiation of a breast phantom on siemens prototype FFDM with and without an anti-scatter grid
    Xia, JQ
    Lo, JY
    Floyd, CE
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 1096 - 1102
  • [30] 16bit Multi-energy Level Detecting Photon Counting ROIC
    Soh, S. Y.
    Jeong, J.
    Han, A.
    Kim, E.
    Hong, K.
    Lee, H.
    Kim, Y.
    Kwak, C.
    Soh, M. J.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 801 - 804