A virtual anti-scatter grid for multi-energy photon counting detector systems

被引:0
|
作者
Purisha, Zenith [1 ,2 ]
Winkler, Alexander [3 ,4 ]
Emzir, Muhammad [1 ,5 ]
Hostettler, Roland [1 ,6 ]
Luukka, Panja [3 ]
Sarkka, Simo [1 ]
机构
[1] Aalto Univ, Dept Elect Engn & Automat, Aalto, Finland
[2] Univ Gadjah Mada, Dept Math, Yogyakarta, Indonesia
[3] Detect Technol Plc, Espoo, Finland
[4] Univ Helsinki, Helsinki Inst Phys, Helsinki, Finland
[5] King Fahd Univ Petr & Minerals, Dept Control & Instrumentat Engn, Dhahran, Saudi Arabia
[6] Uppsala Univ, Dept Engn Sci, Uppsala, Sweden
基金
芬兰科学院;
关键词
virtual; anti-scatter; grids; multi-energy; photon; counting; X-RAY TOMOGRAPHY; STATISTICAL INVERSION; GENERAL FRAMEWORK; CT; GAMMA; BNCT; CONVERGENCE; RADIOGRAPHS;
D O I
10.1088/1402-4896/ad7ce1
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Photon-counting (PC) systems are the next technological generation of medical computed tomography (CT) imaging and is being worked on by all major system providers. CT devices that are based on PC detectors enable multi-energy data collection. The information-content of this data can be used to obtain more detailed patient data, which improves the quality of reconstructions, compared to conventional detector systems. However, PC CT systems are subject to radiation scatter as just as any other imaging systems is. Conventionally anti-scatter grids (ASG) are used to reduce the scatter effect. These are however an imperfect solution, especially for PC detectors. In this work, a software-based scatter correction method, thus a virtual ASG is proposed. The method is tailoring a new statistical model in the measurement space and combining it with the statistical inversion method called Markov chain Monte Carlo (MCMC). The method can recover the measurement data from dense projections. We present the method on simulated data of a single photon emission computed tomography (SPECT) problem for which only under-sampled data is available. However, our approach can in principle be generalised to CT, PC-CT, Positron emission tomography (PET), radiotherapy, or even digital radiography problems. The results show that the proposed model performs similarly as physical ASGs and for cases where ASGs are not possible. The model further offers a significant improvement in the quality of the reconstruction image compared to the image reconstruction from original under-sampled data.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Development of a Multi-Energy Photon-Counting Readout ASIC for CZT Detectors
    Deng, Zhi
    Zhu, Xuezhou
    Chen, Yu
    Liu, Yinong
    Xing, Yuxiang
    Feng, Chuqing
    Wang, Guangqi
    Liu, Hui
    Wu, Sen
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [32] Design, fabrication and testing of a large anti-scatter grid for Megavolt γ-ray imaging
    Watson, S. A.
    Appleby, M.
    Klinger, J.
    Balzer, S.
    Lebeda, C.
    Bowman, D.
    Montoya, J.
    Bultman, D.
    Vecere, C.
    Gossein, C.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 717 - 721
  • [33] Anti-Scatter Grid-Line Artifact Minimization for Removing the Grid Lines for Three Different Grids Used with a High Resolution CMOS Detector
    Rana, R.
    Bednarek, D.
    Rudin, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3328 - 3328
  • [34] Digital selenium radiography: anti-scatter grid for chest radiography in a clinical study
    Bernhardt, TM
    Rapp-Bernhardt, U
    Hausmann, T
    Reichel, G
    Krause, UW
    Doehring, W
    BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (873): : 963 - 968
  • [35] Scatter estimation and removal of anti-scatter grid-line artifacts from anthropomorphic head phantom images taken with a high resolution image detector
    Rana, R.
    Jain, A.
    Shankar, A.
    Bednarek, D. R.
    Rudin, S.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [36] A BAYESIAN APPROACH FOR ANTI-SCATTER GRID EXTRACTION IN X-RAY IMAGING
    Cotte, Florian
    Desvignes, Michel
    Ayasso, Hacheme
    Vignolle, Jean-Michel
    2018 25TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2018, : 1183 - 1187
  • [37] Selective Laser Melting Process and Performance of Pure Tungsten Anti-Scatter Grid
    Wang, Di
    Hu, Weinan
    Yang, Yongqiang
    Feng, Yonwei
    Zhang, Yingjie
    Yi, Hao
    Xiyou Jinshu/Chinese Journal of Rare Metals, 2023, 47 (05): : 757 - 768
  • [38] Modelling and model assessment of grid based multi-energy systems
    Greiml M.
    Traupmann A.
    Sejkora C.
    Kriechbaum L.
    Böckl B.
    Pichler P.
    Kienberger T.
    International Journal of Sustainable Energy Planning and Management, 2020, 29 : 7 - 24
  • [39] Design of linear anti-scatter grid geometry with optimum performance for screen-film and digital mammography systems
    Khodajou-Chokami, H.
    Sohrabpour, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (15): : 5753 - 5765
  • [40] Comparison of the Quantum Efficiency of an Anti-Scatter Grid Vs Air Gaps for Scatter Rejection in the Cardiac Catheterization Laboratory
    Fetterly, K.
    Hindal, M.
    Miller, D.
    Tao, A.
    Schueler, B.
    MEDICAL PHYSICS, 2018, 45 (06) : E218 - E218