Quantitative assessment of areal bone mineral density using multi-energy localizer radiographs from photon-counting detector CT

被引:0
|
作者
Jasper, Soren [1 ]
Swicklik, Joseph [1 ]
Baffour, Francis [1 ]
Ferrero, Andrea [1 ]
El Sadaney, Ahmed O. [1 ]
Shanblatt, Elisabeth [2 ]
Nowak, Tristan [3 ]
Mccollough, Cynthia [1 ]
Rajendran, Kishore [1 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] Siemens Med Solut USA, Malvern, PA USA
[3] Siemens Healthineers, Forchheim, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 22期
关键词
bone density; x-ray absorptiometry; osteoporosis; multidetector computed tomography;
D O I
10.1088/1361-6560/ad8da1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To assess the accuracy and stability of areal bone-mineral-density (aBMD) measurements from multi-energy CT localizer radiographs acquired using photon-counting detector (PCD) CT. Approach. A European Spine Phantom (ESP) with hydroxyapatite (HA 0.5, 1.0 and 1.5 g cm(-2)) was scanned using clinical PCD-CT and a dual-energy x-ray absorptiometry (DXA) to compare aBMD values. To assess aBMD stability and reproducibility, PCD-localizers were acquired twice a day for one week, and once per week for five weeks. Multiple ESP anteroposterior thicknesses (18, 26, 34, and 40 cm) were achieved using a synthetic gel layer and scanned across eight tube current values for both 120 kV (15-120 mA) and 140 kV (10-80 mA). One-way analysis of variance was performed for statistical significance (p < 0.05 considered significant). Quantitative HA and water maps were reconstructed using a prototype material-decomposition software, and aBMD was calculated after background correction. In vivo performance of PCD-based aBMD was illustrated using a patient scan acquired at 140 kV and 40 mA, and lumbar aBMD values were compared with DXA. Main results. The ESP aBMD values from PCD-localizers demonstrated excellent day-to-day stability with a coefficient-of-variation ranging from 0.42% to 0.53%, with mean absolute percentage errors (MAPE) of less than 5% for all three vertebral bodies. The coefficient-of-variation for weekly scans ranged from 0.17% to 0.60%, again with MAPE below 5% for all three vertebral bodies. Across phantom sizes and tube currents, the MAPE values varied ranging from 1.84% to 13.78% for 120 kV, and 1.38%-9.11% for 140 kV. No significant difference was found between different tube currents. For the standard phantom size, DXA showed 11.21% MAPE whereas PCD-CT showed 3.04% MAPE. For the patient scan, deviation between PCD-based aBMD values and those obtained from DXA ranged from 0.07% to 9.82% for different lumbar vertebra. Significance. This study highlights the accuracy and stability of PCD-CT localizers for measuring aBMD. We demonstrated aBMD accuracy across different sizes and showed that higher radiation doses did not inherently increase aBMD accuracy.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Bone Mineral Density Quantification from Localizer Radiographs: Accuracy and Precision of Energy-integrating Detector CT and Photon-counting Detector CT
    Nowak, Tristan
    Eberhard, Matthias
    Schmidt, Bernhard
    Frey, Diana
    Distler, Oliver
    Saltybaeva, Natalia
    Alkadhi, Hatem
    Euler, Andre
    RADIOLOGY, 2021, 298 (01) : 147 - 152
  • [2] Opportunistic Bone Mineral Density Measurement Using Photon-Counting Detector CT Spectral Localizer Images: A Prospective Study
    El Sadaney, Ahmed O.
    Ferrero, Andrea
    Rajendran, Kishore
    Jasper, Soren
    Mazza, Gina L.
    Broski, Stephen M.
    Shanblatt, Elisabeth
    Nowak, Tristan
    Fletcher, Joel G.
    Mccollough, Cynthia H.
    Baffour, Francis I.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2025, 224 (01)
  • [3] Bone Mineral Density Assessment Using Spectral Topograms From a Clinical Photon-Counting Detector CT System: A Phantom Evaluation
    Moser, Lukas J.
    Pitteloud, Janique
    Mergen, Victor
    Frey, Diana
    Nowak, Tristan
    Distler, Oliver
    Eberhard, Matthias
    Alkadhi, Hatem
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 222 (02)
  • [4] Multi-energy CT imaging for large patients using dual-source photon-counting detector CT
    Tao, Shengzhen
    Marsh, Jeffrey F.
    Tao, Ashley
    Michalak, Greg J.
    Rajendran, Kishore
    McCollough, Cynthia H.
    Leng, Shuai
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (17):
  • [5] Quantitative material characterization from multi-energy photon counting CT
    Alessio, Adam M.
    MacDonald, Lawrence R.
    MEDICAL PHYSICS, 2013, 40 (03)
  • [6] Improved Image Reconstruction Using Multi-Energy Information in Spectral Photon-Counting CT
    Niu, Pei
    Wang, Lihui
    Xie, Bingqing
    Robini, Marc
    Boussel, Loic
    Douek, Phillippe
    Zhu, Yuemin
    Yang, Feng
    IEEE ACCESS, 2021, 9 : 97981 - 97989
  • [7] Approaches, advantages, and challenges to photon counting detector and multi-energy CT
    Toia, Giuseppe V.
    Mileto, Achille
    Borhani, Amir A.
    Chen, Guang-Hong
    Ren, Liqiang
    Uyeda, Jennifer W.
    Marin, Daniele
    ABDOMINAL RADIOLOGY, 2024, 49 (09) : 3251 - 3260
  • [8] Spectral CT imaging: Technical principles of dual-energy CT and multi-energy photon-counting CT
    Greffier, Joel
    Villani, Nicolas
    Defez, Didier
    Dabli, Djamel
    Si-Mohamed, Salim
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2023, 104 (04) : 167 - 177
  • [9] Adaptive Multi-Energy Local Mean Filtering for Photon-Counting-Detector Based Multi-Energy CT
    Tao, S.
    Rajendran, K.
    Ferrero, A.
    Zhou, W.
    McCollough, C.
    Leng, S.
    MEDICAL PHYSICS, 2018, 45 (06) : E672 - E672
  • [10] Ultra-High Spatial Resolution, Multi-Energy CT using Photon Counting Detector Technology
    Leng, S.
    Gutjahr, R.
    Ferrero, A.
    Kappler, S.
    Henning, A.
    Halaweish, A.
    Zhou, W.
    Montoya, J.
    McCollough, C.
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132