An 8-Channel Transceiver Coil for Carotid Artery Imaging at 7T Using an Optimized Shield Design

被引:0
|
作者
Yazdanbakhsh, Pedram [1 ,2 ]
Couch, Marcus [1 ,2 ,3 ]
Gilbert, Kyle M. [4 ]
Der Hovagimian, Johnny [1 ,5 ,6 ]
Rudko, David A. [1 ,2 ,5 ]
Hoge, Richard D. [1 ,2 ,5 ]
机构
[1] McGill Univ, Montreal Neurol Inst & Hosp, McConnell Brain Imaging Ctr, Montreal, PQ H3A 0G4, Canada
[2] McGill Univ, Dept Neurol & Neurosurg, Montreal, PQ H3A 0G4, Canada
[3] Siemens Healthcare Ltd, Ottawa, ON, Canada
[4] Western Univ, Ctr Funct & Metab Mapping, London, ON, Canada
[5] McGill Univ, Dept Biomed Engn, Montreal, PQ, Canada
[6] AEM Antennas Inc, Montreal, PQ, Canada
基金
加拿大健康研究院;
关键词
Coils; Radio frequency; Switches; Capacitors; Carotid arteries; Preamplifiers; Phase shifters; 7; tesla; carotid imaging; high-field MRI; parallel transmission; phased array RF coil; ARRAYS;
D O I
10.1109/TBME.2024.3379980
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: To design and fabricate a transmit/receive (T/R) radiofrequency (RF) coil array for MRI of the carotid arteries at 7T with optimal shielding to improve transmit performance in parallel transmit (pTx) mode. Methods: The carotid coil included 8 total RF elements, with left and right subarrays, each consisting of 4 overlapping loops with RF shields. Electromagnetic (EM) simulations were performed to optimize and improve the transmit performance of the array by determining the optimal distance between the RF shield and each subarray. EM simulations were further used to calculate local specific absorption rate (SAR) matrices. Based on the SAR matrices, virtual observation points (VOPs) were applied to ensure safety during parallel transmission. The efficacy of the coil design was evaluated by measuring coil performance metrics when imaging a phantom and by acquiring in-vivo images. Results: The optimal distance between the RF shield and each subarray was determined to be 45 mm. This resulted in a maximum B-1(+) efficiency of 1.23 mu T/$\surd W$ in the carotid arteries and a peak, 10-g-average SAR per Watt of 0.86 kg(-1) when transmitting in the nominal CP+ mode. Optimizing the RF shield resulted in up to 37% improvement in B-1(+) efficiency and 14% improvement in SAR efficiency compared to an unshielded design. Conclusion and significance: Optimizing the distance between the RF shield and coil array provided significant improvement in the transmit characteristics of the bilateral carotid coil. The bilateral coil topology provides a compelling platform for imaging the carotid arteries with high field MRI.
引用
收藏
页码:2537 / 2544
页数:8
相关论文
共 50 条
  • [41] A purpose-built neck coil for black-blood DANTE-prepared carotid artery imaging at 7 T
    Papoutsis, Konstantinos
    Li, Linqing
    Near, Jamie
    Payne, Stephen
    Jezzard, Peter
    MAGNETIC RESONANCE IMAGING, 2017, 40 : 53 - 61
  • [42] Magnetic-Resonance-Based Electrical Property Mapping Using Global Maxwell Tomography With an 8-Channel Head Coil at 7 Tesla: A Simulation Study
    Giannakopoulos, Ilias I.
    Serralles, Jose E. C.
    Daniel, Luca
    Sodickson, Daniel K.
    Polimeridis, Athanasios G.
    White, Jacob K.
    Lattanzi, Riccardo
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (01) : 236 - 246
  • [43] A Novel Flexible Electrotextile 3T MRI RF Coil Array for Carotid Artery Imaging: Design, Characterization, and Prototyping
    Zhang, Daisong
    Rahmat-Samu, Yahya
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2019, 67 (08) : 5115 - 5125
  • [44] An 8-channel Tx/Rx dipole array combined with 16 Rx loops for high-resolution functional cardiac imaging at 7 T
    Steensma, Bart R.
    Voogt, Ingmar J.
    Leiner, Tim
    Luijten, Peter R.
    Habets, Jesse
    Klomp, Dennis W. J.
    van den Berg, Cornelis A. T.
    Raaijmakers, Alexander J. E.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2018, 31 (01) : 7 - 18
  • [45] An 8-channel Tx/Rx dipole array combined with 16 Rx loops for high-resolution functional cardiac imaging at 7 T
    Bart R. Steensma
    Ingmar J. Voogt
    Tim Leiner
    Peter R. Luijten
    Jesse Habets
    Dennis W. J. Klomp
    Cornelis A. T. van den Berg
    Alexander J. E. Raaijmakers
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2018, 31 : 7 - 18
  • [46] Mechanically Adjustable 4-Channel RF Transceiver Coil Array for Rat Brain Imaging in a Whole-Body 7 T MR Scanner
    Roat, Sigrun
    Nohava, Lena
    Laistler, Elmar
    SENSORS, 2024, 24 (16)
  • [47] Advancing 7T perfusion imaging by pulsed arterial spin labeling: Using a parallel transmit coil for enhanced labeling robustness and temporal SNR
    Oliveira, Icaro Agenor Ferreira
    Schnabel, Robin
    van Osch, Matthias J. P.
    van der Zwaag, Wietske
    Hirschler, Lydiane
    PLOS ONE, 2024, 19 (08):
  • [48] Head-and-neck multichannel B1+ mapping and RF shimming of the carotid arteries using a 7T parallel-transmit head coil
    de Buck, Matthijs H. S.
    Kent, James L.
    Jezzard, Peter
    Hess, Aaron T.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (01) : 190 - 204
  • [49] Quantitative 7T sodium magnetic resonance imaging of the human brain using a 32-channel phased-array head coil: Application to patients with secondary progressive multiple sclerosis
    Wilferth, Tobias
    Mennecke, Angelika
    Gast, Lena, V
    Lachner, Sebastian
    Mueller, Max
    Rothhammer, Veit
    Huhn, Konstantin
    Uder, Michael
    Doerfler, Arnd
    Nagel, Armin M.
    Schmidt, Manuel
    NMR IN BIOMEDICINE, 2022, 35 (12)
  • [50] Low SAR 31P (multi-echo) spectroscopic imaging using an integrated whole-body transmit coil at 7T
    van Houtum, Q.
    Welting, D.
    Gosselink, W. J. M.
    Klomp, D. W. J.
    Arteaga de Castro, C. S.
    van der Kemp, W. J. M.
    NMR IN BIOMEDICINE, 2019, 32 (12)