An 8-Channel Transceiver Coil for Carotid Artery Imaging at 7T Using an Optimized Shield Design

被引:0
|
作者
Yazdanbakhsh, Pedram [1 ,2 ]
Couch, Marcus [1 ,2 ,3 ]
Gilbert, Kyle M. [4 ]
Der Hovagimian, Johnny [1 ,5 ,6 ]
Rudko, David A. [1 ,2 ,5 ]
Hoge, Richard D. [1 ,2 ,5 ]
机构
[1] McGill Univ, Montreal Neurol Inst & Hosp, McConnell Brain Imaging Ctr, Montreal, PQ H3A 0G4, Canada
[2] McGill Univ, Dept Neurol & Neurosurg, Montreal, PQ H3A 0G4, Canada
[3] Siemens Healthcare Ltd, Ottawa, ON, Canada
[4] Western Univ, Ctr Funct & Metab Mapping, London, ON, Canada
[5] McGill Univ, Dept Biomed Engn, Montreal, PQ, Canada
[6] AEM Antennas Inc, Montreal, PQ, Canada
基金
加拿大健康研究院;
关键词
Coils; Radio frequency; Switches; Capacitors; Carotid arteries; Preamplifiers; Phase shifters; 7; tesla; carotid imaging; high-field MRI; parallel transmission; phased array RF coil; ARRAYS;
D O I
10.1109/TBME.2024.3379980
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: To design and fabricate a transmit/receive (T/R) radiofrequency (RF) coil array for MRI of the carotid arteries at 7T with optimal shielding to improve transmit performance in parallel transmit (pTx) mode. Methods: The carotid coil included 8 total RF elements, with left and right subarrays, each consisting of 4 overlapping loops with RF shields. Electromagnetic (EM) simulations were performed to optimize and improve the transmit performance of the array by determining the optimal distance between the RF shield and each subarray. EM simulations were further used to calculate local specific absorption rate (SAR) matrices. Based on the SAR matrices, virtual observation points (VOPs) were applied to ensure safety during parallel transmission. The efficacy of the coil design was evaluated by measuring coil performance metrics when imaging a phantom and by acquiring in-vivo images. Results: The optimal distance between the RF shield and each subarray was determined to be 45 mm. This resulted in a maximum B-1(+) efficiency of 1.23 mu T/$\surd W$ in the carotid arteries and a peak, 10-g-average SAR per Watt of 0.86 kg(-1) when transmitting in the nominal CP+ mode. Optimizing the RF shield resulted in up to 37% improvement in B-1(+) efficiency and 14% improvement in SAR efficiency compared to an unshielded design. Conclusion and significance: Optimizing the distance between the RF shield and coil array provided significant improvement in the transmit characteristics of the bilateral carotid coil. The bilateral coil topology provides a compelling platform for imaging the carotid arteries with high field MRI.
引用
收藏
页码:2537 / 2544
页数:8
相关论文
共 50 条
  • [31] Design and Application of Combined 8-Channel Transmit and 10-Channel Receive Arrays and Radiofrequency Shimming for 7-T Shoulder Magnetic Resonance Imaging
    Brown, Ryan
    Deniz, Cem Murat
    Zhang, Bei
    Chang, Gregory
    Sodickson, Daniel K.
    Wiggins, Graham C.
    INVESTIGATIVE RADIOLOGY, 2014, 49 (01) : 35 - 47
  • [32] A 16-channel AC/DC array coil for anesthetized monkey whole-brain imaging at 7T
    Gao, Yang
    Mareyam, Azma
    Sun, Yi
    Witzel, Thomas
    Arango, Nicolas
    Kuang, Irene
    White, Jacob
    Roe, Anna Wang
    Wald, Lawrence
    Stockmann, Jason
    Zhang, Xiaotong
    NEUROIMAGE, 2020, 207
  • [33] Comparison of a 28-channel receive array coil and quadrature volume coil for morphologic imaging and T2 mapping of knee cartilage at 7T
    Chang, Gregory
    Wiggins, Graham C.
    Xia, Ding
    Lattanzi, Riccardo
    Madelin, Guillaume
    Raya, Jose G.
    Finnerty, Matthew
    Fujita, Hiroyuki
    Recht, Michael P.
    Regatte, Ravinder R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (02) : 441 - 448
  • [34] A 16-Channel Receive, Forced Current Excitation Dual-Transmit Coil for Breast Imaging at 7T
    By, Samantha
    Rispoli, Joseph V.
    Cheshkov, Sergey
    Dimitrov, Ivan
    Cui, Jiaming
    Seiler, Stephen
    Goudreau, Sally
    Malloy, Craig
    Wright, Steven M.
    McDougall, Mary Preston
    PLOS ONE, 2014, 9 (11):
  • [35] Design, evaluation and application of a modular 32 channel transmit/receive surface coil array for cardiac MRI at 7T
    A Graessl
    W Renz
    F Hezel
    H Pfeiffer
    W Hoffmann
    P Kellman
    T Niendorf
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [36] Design of 8 channel insertional pTx array coil for 3T body imaging
    Kim, Young Beom
    Ryu, Yeunchul
    Transactions of the Korean Institute of Electrical Engineers, 2014, 63 (04): : 546 - 550
  • [37] Ophthalmic Magnetic Resonance Imaging at 7 T Using a 6-Channel Transceiver Radiofrequency Coil Array in Healthy Subjects and Patients With Intraocular Masses
    Graessl, Andreas
    Muhle, Maximilian
    Schwerter, Michael
    Rieger, Jan
    Oezerdem, Celal
    Santoro, Davide
    Lysiak, Darius
    Winter, Lukas
    Hezel, Fabian
    Waiczies, Sonia
    Guthoff, Rudolf F.
    Falke, Karen
    Hosten, Norbert
    Hadlich, Stefan
    Krueger, Paul-Christian
    Langner, Soenke
    Stachs, Oliver
    Niendorf, Thoralf
    INVESTIGATIVE RADIOLOGY, 2014, 49 (05) : 260 - 270
  • [38] Planar Quadrature RF Transceiver Design Using Common-Mode Differential-Mode (CMDM) Transmission Line Method for 7T MR Imaging
    Li, Ye
    Yu, Baiying
    Pang, Yong
    Vigneron, Daniel B.
    Zhang, Xiaoliang
    PLOS ONE, 2013, 8 (11):
  • [39] Design and Simulation of a Double Tuned RF Coil for 1H and 31P MR imaging at 7T
    Du, F.
    Liu, S.
    Li, N.
    Dou, Y.
    Zhang, X.
    Li, Y.
    2018 IEEE INTERNATIONAL MAGNETIC CONFERENCE (INTERMAG), 2018,
  • [40] High resolution MR imaging of the human eye and orbit at 7T using a dedicated 6-channel eye coil - impact of an optoacoustic triggered MR protocol on imaging quality
    Stachs, Oliver
    Lindner, Tobias
    Rieger, Jan
    Guthoff, Rudolpf F.
    Hosten, Norbert
    Hadlich, Stephan
    Krueger, Paul Christian
    Niendorf, Thoralf
    Langner, Soenke
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)