Magnetic-Resonance-Based Electrical Property Mapping Using Global Maxwell Tomography With an 8-Channel Head Coil at 7 Tesla: A Simulation Study

被引:16
|
作者
Giannakopoulos, Ilias I. [1 ,2 ]
Serralles, Jose E. C. [2 ]
Daniel, Luca [2 ]
Sodickson, Daniel K. [3 ,4 ]
Polimeridis, Athanasios G. [5 ]
White, Jacob K. [2 ]
Lattanzi, Riccardo [3 ,4 ]
机构
[1] Skolkovo Inst Sci & Technol, Skoltech Ctr Computat Data Intens Sci & Engn, Moscow 143026, Russia
[2] MIT, Dept Elect Engn & Comp Sci, Res Lab Elect, Cambridge, MA 02139 USA
[3] NYU, Sch Med, Ctr Adv Imaging Innovat & Res CAI2R, Dept Radiol, New York, NY 10003 USA
[4] NYU, Sch Med, Bernard & Irene Schwartz Ctr Biomed Imaging CBI, New York, NY 10003 USA
[5] Q Bio, Redwood City, CA USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
Global Maxwell Tomography; integral equations; inverse scattering; MR-based electrical property mapping; RF shimming; ultra-high-field magnetic resonance imaging; DIELECTRIC-PROPERTIES; SAR; RECONSTRUCTION; CONDUCTIVITY; EFFICIENT; NETWORK; TISSUES; FIELDS; POWER; EPT;
D O I
10.1109/TBME.2020.2991399
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Global Maxwell Tomography (GMT) is a recently introduced volumetric technique for noninvasive estimation of electrical properties (EP) from magnetic resonance measurements. Previous work evaluated GMT using ideal radiofrequency (RF) excitations. The aim of this simulation study was to assess GMT performance with a realistic RF coil. Methods: We designed a transmit-receive RF coil with 8 decoupled channels for 7T head imaging. We calculated the RF transmit field (B-1(+)) inside heterogeneous head models for different RF shimming approaches, and used them as input for GMT to reconstruct EP for all voxels. Results: Coil tuning/decoupling remained relatively stable when the coil was loaded with different head models. Mean error in EP estimation changed from 7.5% to 9.5% and from 4.8% to 7.2% for relative permittivity and conductivity, respectively, when changing head model without re-tuning the coil. Results slightly improved when an SVD-based RF shimming algorithm was applied, in place of excitation with one coil at a time. Despite errors in EP, RF transmit field (B-1(+)) and absorbed power could be predicted with less than 0.5% error over the entire head. GMT could accurately detect a numerically inserted tumor. Conclusion: This work demonstrates that GMT can reliably reconstruct EP in realistic simulated scenarios using a tailored 8-channel RF coil design at 7T. Future work will focus on construction of the coil and optimization of GMT's robustness to noise, to enable in-vivo GMT experiments. Significance: GMT could provide accurate estimations of tissue EP, which could be used as biomarkers and could enable patient-specific estimation of RF power deposition, which is an unsolved problem for ultra-high-field magnetic resonance imaging.
引用
收藏
页码:236 / 246
页数:11
相关论文
共 3 条
  • [1] Global Maxwell Tomography using an 8-channel radiofrequency coil: simulation results for a tissue-mimicking phantom at 7T
    Giannakopoulos, Ilias I.
    Serralles, Jose E. C.
    Zhang, Bei
    Daniel, Luca
    White, Jacob K.
    Lattanzi, Riccardo
    2019 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION AND USNC-URSI RADIO SCIENCE MEETING, 2019, : 823 - 824
  • [2] An 8-Channel RF Coil based on Microstrip Yagi-antenna for 7T Magnetic Resonance Imaging
    He, Ke
    Yu, Mengxia
    Zhao, E.
    Li, Guiping
    Wang, Maoyan
    Ma, Jing
    2020 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION AND NORTH AMERICAN RADIO SCIENCE MEETING, 2020, : 635 - 636
  • [3] Comparison of an 8-Channel with a 32-Channel Head Coil at 3 Tesla Based on Diffusion-Weighted Imaging with Various b-values: An ACR Phantom Study
    Jang, Ji Sung
    Yoo, Se Jong
    Kim, Seong Ho
    JOURNAL OF MAGNETICS, 2021, 26 (03) : 294 - 298