Comparison of the IOL Master and Pentacam in the measurement of anterior segment parameters in patients with high myopia and cataracts

被引:0
|
作者
Li, L. [1 ]
Li, Y. J. [1 ]
Liu, M. [1 ]
Yu, F. L. [1 ]
机构
[1] Nanchang First Hosp, Dept Ophthalmol, Nanchang 330008, Jiangxi, Peoples R China
来源
JOURNAL FRANCAIS D OPHTALMOLOGIE | 2024年 / 47卷 / 07期
关键词
IOL Master; Pentacam; Myopie & eacute; lev & eacute; e; Cataracte; Param & egrave; tres du segment ant & eacute; rieur; AXIAL LENGTH; SCHEIMPFLUG TOMOGRAPHY; BIOMETRY;
D O I
10.1016/j.jfo.2024.104080
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. - This study aimed to compare the differences between the Zeiss IOL Master and Oculus Pentacam in keratometry and central anterior chamber depth (ACD) measurements in patients with high myopia and cataracts. Methods. - Between January 2019 and December 2020, 89 patients (103 eyes) with cataracts and high myopia who underwent preoperative cataract evaluation at Nanchang First Hospital were selected for retrospective analysis. Keratometry (K1, K2) and ACD were measured with the IOL Master and Pentacam. Paired t-tests were performed to compare the differences, while the Bland-Altman method was used to evaluate the agreement. Results. - The K1 value was (43.15 +/- 2.44) D for the IOL Master and (42.98 +/- 2.47) D for the Pentacam, and the difference between the two instruments was statistically significant (P P < 0.01). The K2 value was (44.55 +/- 2.63) D for the IOL Master and (44.32 +/- 2.55) D for the Pentacam. The ACD was (3.44 +/- 0.33) mm for the IOL Master and (3.39 +/- 0.36) mm for the Pentacam. There were statistically significant differences between the two instruments in both keratometry and ACD (P < 0.01). The absolute values of the maximum difference between the two instruments for K1 and K2 were 1.1 and 1.07; thus, the consistency of the two instruments with respect to this measurement was poor. However, the absolute value of the maximum difference between the two instruments for ACD was 0.34, so the consistency of the two instruments in relation to this measurement was good. Conclusions. - Both the IOL Master and the Pentacam can be used in the measurement of keratometry and ACD in patients with high myopia and cataracts, but the keratometry measurements should be compared in clinical application. (c) 2024 Les Auteurs. Publie par Elsevier Masson SAS.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Comparison of Anterior Segment Biometric Measurements between Pentacam HR and IOLMaster in Normal and High Myopic Eyes
    Dong, Jing
    Tang, Maolong
    Zhang, Yaqin
    Jia, Yading
    Zhang, Haining
    Jia, Zhijie
    Wang, Xiaogang
    PLOS ONE, 2015, 10 (11):
  • [32] Comparison of the biometric parameters in patients with high myopia and anisometropia
    Liu, Jinkun
    Wang, Yuhong
    Huang, Weiyi
    Wang, Fei
    Xu, Yazhang
    Xue, Yingying
    Wu, Mengnan
    Yu, Fei
    Gao, Ruxin
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [33] Comparison of the biometric parameters in patients with high myopia and anisometropia
    Jinkun Liu
    Yuhong Wang
    Weiyi Huang
    Fei Wang
    Yazhang Xu
    Yingying Xue
    Mengnan Wu
    Fei Yu
    Ruxin Gao
    BMC Ophthalmology, 22
  • [34] Linking Anterior and Posterior Segment Biometry in High Myopia
    Khan, Nida Mumtaz
    Dimiskovski, Marko
    Li, Weiye
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [35] Anterior chamber depth measurement before and after photorefractive keratectomy - Comparison between IOL master and Orbscan II
    Rosa, N
    Lanza, M
    Capasso, L
    Lucci, M
    Polito, B
    Romano, A
    OPHTHALMOLOGY, 2006, 113 (06) : 962 - 969
  • [36] The utility of measures of anterior segment parameters of a Pentacam Scheimpflug tomographer in discriminating high myopic astigmatism from keratoconus
    Zaabaar, Ebenezer
    Kyei, Samuel
    Brew, Maame Ama Amamoah Parkson
    Boadi-Kusi, Samuel Bert
    Assiamah, Frank
    Asiedu, Kofi
    PLOS ONE, 2021, 16 (12):
  • [37] Comparison of preoperative and postoperative anterior segment measurements with Pentacam in horizontal muscle surgery
    Emre, S.
    Cankaya, C.
    Demirel, S.
    Doganay, S.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2008, 18 (01) : 7 - 12
  • [38] Effects of 1% cyclopentolate hydrochloride on anterior segment parameters obtained with Pentacam in young adults
    Arici, Ceyhun
    Turk, Adem
    Ceylan, Osman Melih
    Kola, Mehmet
    Hurmeric, Volkan
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2014, 77 (04) : 228 - 232
  • [39] Influence of Ocular Biometry Parameters on the Predictive Accuracy of IOL Power Formulas in Patients with High Myopia
    Ao Miao
    Peimin Lin
    Shaolong Ren
    Jie Xu
    Fan Yang
    Dongjin Qian
    Yi Lu
    Tianyu Zheng
    Ophthalmology and Therapy, 2024, 13 : 435 - 448
  • [40] Influence of Ocular Biometry Parameters on the Predictive Accuracy of IOL Power Formulas in Patients with High Myopia
    Miao, Ao
    Lin, Peimin
    Ren, Shaolong
    Xu, Jie
    Yang, Fan
    Qian, Dongjin
    Lu, Yi
    Zheng, Tianyu
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (01) : 435 - 448