Comparison of the IOL Master and Pentacam in the measurement of anterior segment parameters in patients with high myopia and cataracts

被引:0
|
作者
Li, L. [1 ]
Li, Y. J. [1 ]
Liu, M. [1 ]
Yu, F. L. [1 ]
机构
[1] Nanchang First Hosp, Dept Ophthalmol, Nanchang 330008, Jiangxi, Peoples R China
来源
JOURNAL FRANCAIS D OPHTALMOLOGIE | 2024年 / 47卷 / 07期
关键词
IOL Master; Pentacam; Myopie & eacute; lev & eacute; e; Cataracte; Param & egrave; tres du segment ant & eacute; rieur; AXIAL LENGTH; SCHEIMPFLUG TOMOGRAPHY; BIOMETRY;
D O I
10.1016/j.jfo.2024.104080
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. - This study aimed to compare the differences between the Zeiss IOL Master and Oculus Pentacam in keratometry and central anterior chamber depth (ACD) measurements in patients with high myopia and cataracts. Methods. - Between January 2019 and December 2020, 89 patients (103 eyes) with cataracts and high myopia who underwent preoperative cataract evaluation at Nanchang First Hospital were selected for retrospective analysis. Keratometry (K1, K2) and ACD were measured with the IOL Master and Pentacam. Paired t-tests were performed to compare the differences, while the Bland-Altman method was used to evaluate the agreement. Results. - The K1 value was (43.15 +/- 2.44) D for the IOL Master and (42.98 +/- 2.47) D for the Pentacam, and the difference between the two instruments was statistically significant (P P < 0.01). The K2 value was (44.55 +/- 2.63) D for the IOL Master and (44.32 +/- 2.55) D for the Pentacam. The ACD was (3.44 +/- 0.33) mm for the IOL Master and (3.39 +/- 0.36) mm for the Pentacam. There were statistically significant differences between the two instruments in both keratometry and ACD (P < 0.01). The absolute values of the maximum difference between the two instruments for K1 and K2 were 1.1 and 1.07; thus, the consistency of the two instruments with respect to this measurement was poor. However, the absolute value of the maximum difference between the two instruments for ACD was 0.34, so the consistency of the two instruments in relation to this measurement was good. Conclusions. - Both the IOL Master and the Pentacam can be used in the measurement of keratometry and ACD in patients with high myopia and cataracts, but the keratometry measurements should be compared in clinical application. (c) 2024 Les Auteurs. Publie par Elsevier Masson SAS.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Comparison of anterior segment parameters in myopia with and without primary open-angle glaucoma
    Kyei, Samuel
    Zaabaar, Ebenezer
    Boadi-Kusi, Samuel Bert
    Abowine, John Baptist Vianney
    Brew, Maame Ama Amamoah Parkson
    Assiamah, Frank
    Asiedu, Kofi
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (07) : 2307 - 2313
  • [22] The anterior segment biometrics in high myopia eyes
    Li, Mu
    Luo, Zhaoxia
    Yan, Xiaoqin
    Chen, Zhiqi
    OPHTHALMIC RESEARCH, 2023, 66 (01) : 75 - 85
  • [23] Comparison of IOL Power Calculation Formulas for a Trifocal IOL in Eyes With High Myopia
    Tan, Qian
    Lin, Ding
    Wang, Li
    Chen, Bichao
    Tang, Qiongyan
    Chen, Xu
    Chen, Maosheng
    Tan, Jilin
    Zhang, Jingsong
    Wu, Lei
    Zhu, Xiaojun
    Wang, Yong
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (08) : 538 - +
  • [24] Comparison of Preoperative and Postoperative Anterior Segment Measurements With Pentacam® in Strabismus Surgery
    Jung, Jae Ho
    Choi, Hee Young
    JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2012, 49 (05) : 290 - 294
  • [25] Comparison of IOL-Master 700 and IOL-Master 500 biometers in ocular biological parameters of adolescents
    Qiang Shi
    Guang-Yan Wang
    Yu-Hong Cheng
    Cheng Pei
    International Journal of Ophthalmology, 2021, 14 (07) : 1013 - 1017
  • [26] Comparison of IOL-Master 700 and IOL-Master 500 biometers in ocular biological parameters of adolescents
    Shi, Qiang
    Wang, Guang-Yan
    Cheng, Yu-Hong
    Pei, Cheng
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2021, 14 (07) : 1013 - 1017
  • [27] Evaluation of Pentacam-Scheimpflug imaging of anterior segment parameters in patients with pseudoexfoliation syndrome and pseudoexfoliative glaucoma
    Doganay, Selim
    Tasar, Ahmet
    Cankaya, Cem
    Firat, Penpe Gul
    Yologlu, Saim
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2012, 95 (02) : 218 - 222
  • [28] Anterior segment parameters in normal dogs using the Pentacam® HR Scheimpflug system
    Wolfel, Allison E.
    Pederson, Samantha L.
    Cleymaet, Allison M.
    Hess, Ann M.
    Freeman, Kate S.
    VETERINARY OPHTHALMOLOGY, 2019, 22 (05) : 683 - 694
  • [29] Accuracy of Prediction of Steep Axis and Cylinder Power Using IOL Master versus Pentacam in Patients Undergoing Toric IOL Implantation
    Brown, Sarah Elise
    Miller, Darby
    Ostrovsky, Ann
    Wallenstein, Sylvan
    Speaker, Mark
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [30] Comparison of Anterior Segment Parameters Between Phakic and Pseudophakic Eyes of Subjects with Emmetropia and Degenerative Myopia
    Demir, Mehmet
    Akpolat, Cetin
    Arslan, Gurcan Dogukan
    Sendul, Yekta
    ACTA OPHTHALMOLOGICA, 2019, 97