Comparison of the IOL Master and Pentacam in the measurement of anterior segment parameters in patients with high myopia and cataracts

被引:0
|
作者
Li, L. [1 ]
Li, Y. J. [1 ]
Liu, M. [1 ]
Yu, F. L. [1 ]
机构
[1] Nanchang First Hosp, Dept Ophthalmol, Nanchang 330008, Jiangxi, Peoples R China
来源
JOURNAL FRANCAIS D OPHTALMOLOGIE | 2024年 / 47卷 / 07期
关键词
IOL Master; Pentacam; Myopie & eacute; lev & eacute; e; Cataracte; Param & egrave; tres du segment ant & eacute; rieur; AXIAL LENGTH; SCHEIMPFLUG TOMOGRAPHY; BIOMETRY;
D O I
10.1016/j.jfo.2024.104080
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. - This study aimed to compare the differences between the Zeiss IOL Master and Oculus Pentacam in keratometry and central anterior chamber depth (ACD) measurements in patients with high myopia and cataracts. Methods. - Between January 2019 and December 2020, 89 patients (103 eyes) with cataracts and high myopia who underwent preoperative cataract evaluation at Nanchang First Hospital were selected for retrospective analysis. Keratometry (K1, K2) and ACD were measured with the IOL Master and Pentacam. Paired t-tests were performed to compare the differences, while the Bland-Altman method was used to evaluate the agreement. Results. - The K1 value was (43.15 +/- 2.44) D for the IOL Master and (42.98 +/- 2.47) D for the Pentacam, and the difference between the two instruments was statistically significant (P P < 0.01). The K2 value was (44.55 +/- 2.63) D for the IOL Master and (44.32 +/- 2.55) D for the Pentacam. The ACD was (3.44 +/- 0.33) mm for the IOL Master and (3.39 +/- 0.36) mm for the Pentacam. There were statistically significant differences between the two instruments in both keratometry and ACD (P < 0.01). The absolute values of the maximum difference between the two instruments for K1 and K2 were 1.1 and 1.07; thus, the consistency of the two instruments with respect to this measurement was poor. However, the absolute value of the maximum difference between the two instruments for ACD was 0.34, so the consistency of the two instruments in relation to this measurement was good. Conclusions. - Both the IOL Master and the Pentacam can be used in the measurement of keratometry and ACD in patients with high myopia and cataracts, but the keratometry measurements should be compared in clinical application. (c) 2024 Les Auteurs. Publie par Elsevier Masson SAS.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] RETRACTED: Clinical Study on the Differential Diagnosis of High Myopia Astigmatism and Subclinical Keratoconus in Adolescents by Pentacam Anterior Segment Analyzer (Retracted Article)
    Ruan, Yimeng
    Zhang, Ying
    Ying, Xiaohong
    CONTRAST MEDIA & MOLECULAR IMAGING, 2022, 2022
  • [42] Evaluation of anterior segment parameters using the Pentacam in hyperopic anisometropic amblyopic and normal eyes
    Yuksel, Nilay
    Yuksel, Erdem
    Ozer, Mediha Dilek
    JOURNAL OF AAPOS, 2014, 18 (03): : 248 - 250
  • [43] Effects of Cyclopentolate Hydrochloride Dosage on Anterior Segment Parameters in Young Adults (Measured with Pentacam)
    Alghamdi, Waleed M.
    Alrasheed, Saif H.
    Nair, Vishakh
    Alluwimi, Muhammed S.
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 891 - 898
  • [44] Anterior Chamber Depth Measurement in Pseudophakic Eyes: A Comparison of Pentacam and Ultrasound
    Savini, Giacomo
    Olsen, Thomas
    Carbonara, Claudio
    Pazzaglia, Sebastiano
    Barboni, Piero
    Carbonelli, Michele
    Hoffer, Kenneth J.
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (05) : 341 - 347
  • [45] Evaluation of anterior segment parameters using pentacam in silicone oil-injected patients after pars plana vitrectomy
    Calik, Burcu
    Ozturk, Muzaffer
    Serdarogullari, Huseyin
    Elcioglu, Mustafa
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2013, 61 (11) : 621 - 625
  • [46] REPRODUCIBILITY OF MEASUREMENT OF ANTERIOR SEGMENT PARAMETERS BY HIGH-RESOLUTION ULTRASOUND BIOMICROSCOPY
    TELLO, C
    POTASH, SD
    LIEBMANN, JM
    STEINBERGER, D
    RITCH, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 1384 - 1384
  • [47] Comparison of the Corneal Power Measurements with the TMS4-Topographer, Pentacam HR, IOL Master, and Java']Javal Keratometer
    Dehnavi, Zahra
    Khabazkhoob, Mehdi
    Mirzajani, Ali
    Jabbarvand, Mahmood
    Yekta, Abbasali
    Jafarzadehpur, Ebrahim
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2015, 22 (02) : 233 - 237
  • [48] Evaluation of the Anterior Chamber Parameters by Pentacam after Toric Implantable Phakic Contact lens (IPCL) Implantation in Moderate to High Myopia with Astigmatism
    Mahmoud, Mohamed Salah El-Din
    Hamid, Mohamed Abdel
    Esmail, Mohamed Esmail Khalil
    Halim, Ahmed Abdel
    OPEN OPHTHALMOLOGY JOURNAL, 2022, 16
  • [49] Combined Special Capsular Tension Ring and Toric IOL Implantation for Management of Astigmatism and High Axial Myopia with Cataracts
    Zhao, Yang
    Li, Jiaxin
    Yang, Ke
    Li, Xiao
    Zhu, Siquan
    SEMINARS IN OPHTHALMOLOGY, 2018, 33 (03) : 389 - 394
  • [50] Identification of Schlemm's Canal by Anterior Segment Optical Coherence Tomography in patients with High Myopia
    Nomura, Takuhei
    Yoshida, Takeshi
    Aihara, Makoto
    Ohno-Matsui, Kyoko
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)