anterior chamber angle; anterior chamber depth; central corneal thickness; corneal volume; glaucoma; pseudoexfoliation; pupil; Scheimpflug imaging system; OPTICAL COHERENCE TOMOGRAPHY; OPEN-ANGLE GLAUCOMA; INTRAOCULAR-LENS IMPLANTATION; CORNEAL THICKNESS; EXFOLIATION SYNDROME; CHAMBER DEPTH; ULTRASOUND BIOMICROSCOPY; CATARACT-SURGERY; CLOSURE GLAUCOMA; EYES;
D O I
10.1111/j.1444-0938.2011.00691.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: The aim was to evaluate anterior segment parameters in patients with pseudoexfoliation syndrome (PXS) or pseudoexfoliative glaucoma (PXG) with the Pentacam-Scheimpflug imaging system. Methods: Eighty eyes of 53 patients with PXS (Group 1), 80 eyes of 57 patients with PXG (Group 2) and 80 eyes of 45 control cases (Group 3) were included in the study. Anterior chamber depth, volume (ACV), angle (ACA) width, central corneal thickness (CCT), central 3.0, 5.0 and 7.0 mm corneal volumes and pupil diameters were compared between groups. Results: Although anterior chamber depths in the PXG group were significantly lower than the control group (p < 0.05), there was no statistically significant difference between the PXS group and the control group in means of anterior chamber depth values (p > 0.05). There were no statistically significant differences among PXS, PXG and the control group in mean values of ACV, ACA width, CCT, pupil diameters and central 3.0, 5.0 and 7.0 mm corneal volume (p > 0.05). Conclusions: The anterior chamber depths of PXG patients were lower than those of healthy individuals. Although the difference in anterior chamber depth between PXG patients and normal patients was statistically significant, this finding is unlikely to be of clinical significance. The anterior chamber depths of PXS patients were similar to those of healthy individuals. There were no significant differences in the means of ACV, ACA width, CCT, pupil diameter and corneal volume values on central 3.0, 5.0 and 7.0 mm among patients with PXS, PXG and healthy individuals.
引用
收藏
页码:218 / 222
页数:5
相关论文
共 50 条
  • [1] Evaluation of anterior segment parameters in patients with pseudoexfoliation syndrome using Scheimpflug imaging
    Gunes, Alime
    Yigit, Musa
    Tok, Levent
    Tok, Ozlem
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2016, 79 (03) : 177 - 179
  • [2] Evaluation of Anterior Segment Parameters in Pseudoexfoliation Syndrome Patients
    Acar, Banu Torun
    Buttanri, Ibrahim Bulent
    Sevim, Mehmet Sahin
    Esen, Didem
    Acar, Suphi
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2010, 40 (04): : 217 - 221
  • [3] Evaluation of anterior segment parameters in patients with Turner syndrome using Scheimpflug imaging
    Inanc, Merve
    Tekin, Kemal
    Kurnaz, Erdal
    Citirik, Mehmet
    Altas, Gulsah
    Aycan, Zehra
    JOURNAL OF AAPOS, 2018, 22 (01): : 56 - 60
  • [4] Comparison of anterior segment parameters in patients with pseudoexfoliation glaucoma, patients with pseudoexfoliation syndrome, and normal subjects
    Kaygisiz, Mehmet
    Elgin, Ufuk
    Tekin, Kemal
    Sen, Emine
    Yilmazbas, Pelin
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2018, 81 (02) : 110 - 115
  • [5] Retrobulbar hemodynamic parameters in pseudoexfoliation syndrome and pseudoexfoliative glaucoma
    Antonio Martinez
    Manuel Sanchez
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2008, 246
  • [6] Retrobulbar hemodynamic parameters in pseudoexfoliation syndrome and pseudoexfoliative glaucoma
    Martinez, Antonio
    Sanchez, Manuel
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2008, 246 (09) : 1341 - 1349
  • [7] Evaluation of Anterior Segment Parameters in Pseudoexfoliative Glaucoma, Primary Angle-Closure Glaucoma, and Healthy Eyes
    Aksoy, Nilgun Ozkan
    Cakir, Burcin
    Dogan, Emine
    Alagoz, Gursoy
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2018, 48 (05): : 227 - 231
  • [8] Anterior segment parameters in normal dogs using the Pentacam® HR Scheimpflug system
    Wolfel, Allison E.
    Pederson, Samantha L.
    Cleymaet, Allison M.
    Hess, Ann M.
    Freeman, Kate S.
    VETERINARY OPHTHALMOLOGY, 2019, 22 (05) : 683 - 694
  • [9] Evaluation of anterior chamber imaging parameters in pseudoexfoliation patients
    Mohamed-Noriega, Jibran
    Mohamed-Noriega, Karim
    Ruiz-Gonzalez, Jesus Alberto
    Martinez-Lopez-Portillo, Alejandro
    Mohamed-Hamsho, Jesus
    Cavazos, Humberto
    Gonzalez, Jesus Hernan
    Cuervo-Lozano, Edgar Eliezer
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [10] Evaluation of Anterior Scleral Thickness and Angle Parameters in Eyes with Pseudoexfoliation Syndrome and Glaucoma
    Alpogan, Oksan
    Un, Yasemin
    Tekcan, Hatice
    Kose, Alev Ozcelik
    Bolac, Ruveyde
    JOURNAL OF GLAUCOMA, 2024, 33 (10) : 785 - 793