Evaluation of Pentacam-Scheimpflug imaging of anterior segment parameters in patients with pseudoexfoliation syndrome and pseudoexfoliative glaucoma

被引:31
|
作者
Doganay, Selim [1 ]
Tasar, Ahmet
Cankaya, Cem
Firat, Penpe Gul
Yologlu, Saim [2 ]
机构
[1] Inonu Univ, Sch Med, Turgut Ozal Med Ctr, Dept Ophthalmol, TR-44280 Malatya, Turkey
[2] Inonu Univ, Sch Med, Dept Biostat, TR-44280 Malatya, Turkey
关键词
anterior chamber angle; anterior chamber depth; central corneal thickness; corneal volume; glaucoma; pseudoexfoliation; pupil; Scheimpflug imaging system; OPTICAL COHERENCE TOMOGRAPHY; OPEN-ANGLE GLAUCOMA; INTRAOCULAR-LENS IMPLANTATION; CORNEAL THICKNESS; EXFOLIATION SYNDROME; CHAMBER DEPTH; ULTRASOUND BIOMICROSCOPY; CATARACT-SURGERY; CLOSURE GLAUCOMA; EYES;
D O I
10.1111/j.1444-0938.2011.00691.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: The aim was to evaluate anterior segment parameters in patients with pseudoexfoliation syndrome (PXS) or pseudoexfoliative glaucoma (PXG) with the Pentacam-Scheimpflug imaging system. Methods: Eighty eyes of 53 patients with PXS (Group 1), 80 eyes of 57 patients with PXG (Group 2) and 80 eyes of 45 control cases (Group 3) were included in the study. Anterior chamber depth, volume (ACV), angle (ACA) width, central corneal thickness (CCT), central 3.0, 5.0 and 7.0 mm corneal volumes and pupil diameters were compared between groups. Results: Although anterior chamber depths in the PXG group were significantly lower than the control group (p < 0.05), there was no statistically significant difference between the PXS group and the control group in means of anterior chamber depth values (p > 0.05). There were no statistically significant differences among PXS, PXG and the control group in mean values of ACV, ACA width, CCT, pupil diameters and central 3.0, 5.0 and 7.0 mm corneal volume (p > 0.05). Conclusions: The anterior chamber depths of PXG patients were lower than those of healthy individuals. Although the difference in anterior chamber depth between PXG patients and normal patients was statistically significant, this finding is unlikely to be of clinical significance. The anterior chamber depths of PXS patients were similar to those of healthy individuals. There were no significant differences in the means of ACV, ACA width, CCT, pupil diameter and corneal volume values on central 3.0, 5.0 and 7.0 mm among patients with PXS, PXG and healthy individuals.
引用
收藏
页码:218 / 222
页数:5
相关论文
共 50 条
  • [41] Swept Source Optical Coherence Tomography Analysis of a Selected Eye's Anterior Segment Parameters in Patients with Pseudoexfoliation Syndrome
    Dembski, Michal
    Nowinska, Anna
    Ulfik-Dembska, Klaudia
    Wylegala, Edward
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (01)
  • [42] Assessment by the Scheimpflug imaging system of corneal clarity and anterior segment properties in rosacea patients
    Bozali, Erman
    Yeter, Duygu Yalinbas
    Tosun, Mustafa
    Apa, Anil Selim
    ANAIS BRASILEIROS DE DERMATOLOGIA, 2024, 99 (04) : 513 - 519
  • [43] Evaluation of Corneal Parameters with Scheimpflug Imaging in Patients with Rheumatoid Arthritis
    Cingu, Abdullah Kursat
    Cinar, Yasin
    Turkcu, Fatih Mehmet
    Sahin, Muhammed
    Kaya, Savas
    Bozkurt, Mehtap
    Sahin, Alparslan
    Yuksel, Harun
    Ari, Seyhmus
    Caca, Ihsan
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2013, 21 (05) : 360 - 365
  • [44] Comparison of the IOL Master and Pentacam in the measurement of anterior segment parameters in patients with high myopia and cataracts
    Li, L.
    Li, Y. J.
    Liu, M.
    Yu, F. L.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2024, 47 (07):
  • [45] Changes in Anterior Chamber Parameters with the Pentacam Rotating Scheimpflug and Axial Length Measurements by Ultrasound in Patients Who Use Isotretinoin
    Cumurcu, Tongabay
    Sener, Serpil
    Ozsoy, Ercan
    Doganay, Selim
    CURRENT EYE RESEARCH, 2012, 37 (05) : 395 - 398
  • [46] Repeatability and Agreement of Three Scheimpflug-Based Imaging Systems for Measuring Anterior Segment Parameters in Keratoconus
    Shetty, Rohit
    Arora, Vishal
    Jayadev, Chaitra
    Nuijts, Rudy M. M. A.
    Kumar, Mukesh
    Puttaiah, Narendra K.
    Kummelil, Mathew Kurian
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (08) : 5263 - 5268
  • [47] Evaluation of anterior segment parameters between pregnancy trimesters and postpartum with pentacam scheimflug ımaging: a prospective study
    Pota, Cisil Erkan
    Yaprak, Asli Cetinkaya
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [48] Repeatability of Scheimpflug imaging and anterior segment optical coherence tomography parameters in keratoconus is decreasing with increasing severity
    Seitz, Berthold
    Elzer, Berit
    Spira-Eppig, Corinna
    Langenbucher, Achim
    Zemova, Elena
    Szentmary, Nora
    Eppig, Timo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [49] Tissue inhibitor of metalloproteinase 4 in aqueous humor of patients with primary open angle glaucoma, pseudoexfoliation syndrome and pseudoexfoliative glaucoma and its role in proteolysis imbalance
    Fountoulakis, Nikitas
    Labiris, Georgios
    Aristeidou, Antonios
    Katsanos, Andreas
    Tentes, Ioannis
    Kortsaris, Alexandros
    Kozobolis, Vassilios P.
    BMC OPHTHALMOLOGY, 2013, 13
  • [50] Tissue inhibitor of metalloproteinase 4 in aqueous humor of patients with primary open angle glaucoma, pseudoexfoliation syndrome and pseudoexfoliative glaucoma and its role in proteolysis imbalance
    Nikitas Fountoulakis
    Georgios Labiris
    Antonios Aristeidou
    Andreas Katsanos
    Ioannis Tentes
    Alexandros Kortsaris
    Vassilios P Kozobolis
    BMC Ophthalmology, 13