Evaluation of Pentacam-Scheimpflug imaging of anterior segment parameters in patients with pseudoexfoliation syndrome and pseudoexfoliative glaucoma

被引:31
|
作者
Doganay, Selim [1 ]
Tasar, Ahmet
Cankaya, Cem
Firat, Penpe Gul
Yologlu, Saim [2 ]
机构
[1] Inonu Univ, Sch Med, Turgut Ozal Med Ctr, Dept Ophthalmol, TR-44280 Malatya, Turkey
[2] Inonu Univ, Sch Med, Dept Biostat, TR-44280 Malatya, Turkey
关键词
anterior chamber angle; anterior chamber depth; central corneal thickness; corneal volume; glaucoma; pseudoexfoliation; pupil; Scheimpflug imaging system; OPTICAL COHERENCE TOMOGRAPHY; OPEN-ANGLE GLAUCOMA; INTRAOCULAR-LENS IMPLANTATION; CORNEAL THICKNESS; EXFOLIATION SYNDROME; CHAMBER DEPTH; ULTRASOUND BIOMICROSCOPY; CATARACT-SURGERY; CLOSURE GLAUCOMA; EYES;
D O I
10.1111/j.1444-0938.2011.00691.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: The aim was to evaluate anterior segment parameters in patients with pseudoexfoliation syndrome (PXS) or pseudoexfoliative glaucoma (PXG) with the Pentacam-Scheimpflug imaging system. Methods: Eighty eyes of 53 patients with PXS (Group 1), 80 eyes of 57 patients with PXG (Group 2) and 80 eyes of 45 control cases (Group 3) were included in the study. Anterior chamber depth, volume (ACV), angle (ACA) width, central corneal thickness (CCT), central 3.0, 5.0 and 7.0 mm corneal volumes and pupil diameters were compared between groups. Results: Although anterior chamber depths in the PXG group were significantly lower than the control group (p < 0.05), there was no statistically significant difference between the PXS group and the control group in means of anterior chamber depth values (p > 0.05). There were no statistically significant differences among PXS, PXG and the control group in mean values of ACV, ACA width, CCT, pupil diameters and central 3.0, 5.0 and 7.0 mm corneal volume (p > 0.05). Conclusions: The anterior chamber depths of PXG patients were lower than those of healthy individuals. Although the difference in anterior chamber depth between PXG patients and normal patients was statistically significant, this finding is unlikely to be of clinical significance. The anterior chamber depths of PXS patients were similar to those of healthy individuals. There were no significant differences in the means of ACV, ACA width, CCT, pupil diameter and corneal volume values on central 3.0, 5.0 and 7.0 mm among patients with PXS, PXG and healthy individuals.
引用
收藏
页码:218 / 222
页数:5
相关论文
共 50 条
  • [31] Reply to Comment on: "Evaluation of Anterior Segment Parameters in Pseudoexfoliation Disease Using Anterior Segment Optical Coherence Tomography"
    Mohammadi, Massood
    Johari, Mohammadkarim
    Eslami, Yadollah
    Zarei, Reza
    Fakhraie, Ghasem
    Safizadeh, Mona
    Moghimi, Sasan
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 238 : 198 - 198
  • [32] Magnetic resonance imaging of the brain in patients with pseudoexfoliation syndrome and glaucoma
    Yüksel, N
    Anik, Y
    Altintas, Ö
    Onur, I
    Çaglar, Y
    Demirci, A
    OPHTHALMOLOGICA, 2006, 220 (02) : 125 - 130
  • [33] Evaluation of Tear Fluid and Aqueous Humor Concentration of Clusterin as Biomarkers for Early Diagnosis of Pseudoexfoliation Syndrome and Pseudoexfoliative Glaucoma
    Demirdogen, Birsen Can
    Demirkaya-Budak, Sinem
    Ozge, Gokhan
    Mumcuoglu, Tarkan
    CURRENT EYE RESEARCH, 2020, 45 (07) : 805 - 813
  • [34] Early Postoperative Effects of Cataract Surgery on Anterior Segment Parameters in Primary Open-Angle Glaucoma and Pseudoexfoliation Glaucoma
    Elgin, Ufuk
    Sen, Emine
    Simsek, Tulay
    Tekin, Kemal
    Yilmazbas, Pelin
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2016, 46 (03): : 95 - 98
  • [35] Evaluation of anterior segment parameters using the Pentacam in hyperopic anisometropic amblyopic and normal eyes
    Yuksel, Nilay
    Yuksel, Erdem
    Ozer, Mediha Dilek
    JOURNAL OF AAPOS, 2014, 18 (03): : 248 - 250
  • [36] Evaluation of anterior segment parameters by topography and optical biometry according to the localization of pseudoexfoliation material
    Oz, Furkan
    Mesen, Ali
    Mesen, Selma
    INTERNATIONAL OPHTHALMOLOGY, 2025, 45 (01)
  • [37] Evaluation of the Anterior Segment Parameters of the Patients with Scleroderma
    Sahin, Muhammed
    Yuksel, Harun
    Sahin, Alparslan
    Cingue, Abdullah Kursat
    Turkcu, Fatih Mehmet
    Kaya, Savas
    Yazmalar, Levent
    Batmaz, Ibrahim
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2017, 25 (02) : 233 - 238
  • [38] Age- and sex-related differences in the measures of anterior segment parameters in a myopic clinical sample using Pentacam Scheimpflug tomography
    Kyei, Samuel
    Abowine, John Baptist Vianney
    Zaabaar, Ebenezer
    Boadi-Kusi, Samuel Bert
    Assiamah, Frank
    Abdul-Kabir, Mohammed
    Asiedu, Kofi
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (05) : 1573 - 1580
  • [39] Age- and sex-related differences in the measures of anterior segment parameters in a myopic clinical sample using Pentacam Scheimpflug tomography
    Samuel Kyei
    John Baptist Vianney Abowine
    Ebenezer Zaabaar
    Samuel Bert Boadi-Kusi
    Frank Assiamah
    Mohammed Abdul-Kabir
    Kofi Asiedu
    International Ophthalmology, 2022, 42 : 1573 - 1580
  • [40] Evaluation of anterior segment parameters using pentacam in silicone oil-injected patients after pars plana vitrectomy
    Calik, Burcu
    Ozturk, Muzaffer
    Serdarogullari, Huseyin
    Elcioglu, Mustafa
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2013, 61 (11) : 621 - 625