摘要
Purpose: To measure the anterior chamber depth (ACD) with 2 different devices before and after photorefractive keratectomy (PRK). Design: Noncomparative case series. Participants: One hundred forty-three eyes of 143 patients who had undergone PRK with refractive errors ranging from -13.13 diopters (D) to +7 D (mean, -3.67 +/- 3.58) were analyzed. Methods: The ACD values preoperatively and at 1, 3, and 6 months postoperatively were measured with the Orbscan II and IOL Master. The results were analyzed using the Pearson correlation. Main Outcome Measure: Anterior chamber depth. Results: The instruments showed good agreement between the measurements before and after surgery. A significant decrease between the preoperative and 1-month postoperative measurements was found in the ACD measured from the epithelium with Orbscan II (P < 0.01) and IOL Master (P < 0.01). A nonsignificant decrease with both IOL Master (P > 0.01) and Orbscan II (P > 0.01) was found between 3 and 6 months after surgery. The ACD measured from the endothelium using the Orbscan II showed a significant difference only between the 3- and 6-month follow-up data (P < 0.01). Conclusions: The 2 devices showed good agreement, and the changes detected postoperatively seem to be related not only to corneal thinning but also to anterior segment remodeling.
引用
收藏
页码:962 / 969
页数:8
相关论文
共 50 条
  • [1] Anterior chamber depth measurement before and after photorefractive keratectomy. Comparison between IOLMaster and Pentacam
    De Bernardo, Maddalena
    Borrelli, Maria
    Imparato, Roberto
    Cione, Ferdinando
    Rosa, Nicola
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2020, 32
  • [2] Comparison of IOL master and ultrasound biomicroscopy in anterior chamber depth measurement
    Zhou, Wen-Kai
    Li, Xiao-Yan
    Zhang, Jin-Song
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2009, 2 (04): : 352 - 354
  • [3] Comparison of anterior chamber depth measurement between Orbscan IIz and ultrasound biomicroscopy
    Lee, Jong Yun
    Kim, Jun-Heon
    Kim, Hyo-Myung
    Song, Jong-Suk
    JOURNAL OF REFRACTIVE SURGERY, 2007, 23 (05) : 487 - 491
  • [4] Pentacam and Orbscan II Measurements of Posterior Corneal Elevation Before and After Photorefractive Keratectomy
    Ha, Byoung Jin
    Kim, Sun Woong
    Kim, Sang Woo
    Kim, Eung Kweon
    Kim, Tae-im
    JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (03) : 290 - 295
  • [5] Comparison of anterior chamber depth measurements using Orbscan II and IOLMaster
    Frisch, I. B.
    Rabsilber, T. M.
    Becker, K. A.
    Reuland, A. J.
    Auffarth, G. U.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2007, 17 (03) : 327 - 331
  • [6] Anterior chamber flare after photorefractive keratectomy
    TomasBarberan, S
    Fagerholm, P
    JOURNAL OF REFRACTIVE SURGERY, 1996, 12 (01): : 103 - 107
  • [7] Comparison of Anterior Chamber Depth measures obtained with IOL Master® 500 and Pentacam®
    Marques, Daniela Lemos
    Teixeira, Ivan Corso
    Hida, Richard Y.
    Langella, Fabricio
    Kurimori, Helena
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [8] Comparasion of Orbscan II Topography and Ultrasound Biometry in the Measurement of Anterior Chamber Depth
    Zengin, Ozgur
    Selver, Ozlem Barut
    Ozbek, Zeynep
    Yaman, Aylin
    Durak, Ismel
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2009, 39 (01): : 27 - 31
  • [9] Anterior chamber depth measurement with A-scan ultrasonography, Orbscan II, and IOLMaster
    Hashemi, H
    Yazdani, K
    Mehravaran, S
    Fotouhi, A
    OPTOMETRY AND VISION SCIENCE, 2005, 82 (10) : 900 - 904
  • [10] Comparison of anterior chamber depth measurements using Galilei, HR Pentacam, and Orbscan II
    Salouti, Ramin
    Nowroozzadeh, Mohammad H.
    Zamani, Mohammad
    Ghoreyshi, Maryam
    Salouti, Rosa
    OPTOMETRY-JOURNAL OF THE AMERICAN OPTOMETRIC ASSOCIATION, 2010, 81 (01) : 35 - 39