Evaluation of the QMAC-dRAST System Version 2.5 for Rapid Antimicrobial Susceptibility Testing of Gram-Negative Bacteria From Positive Blood Culture Broth and Subcultured Colony Isolates

被引:2
|
作者
Kim, Tae Yeul [1 ]
Kang, Minhee [2 ,3 ]
Shim, Hyang Jin [4 ]
Kang, On-Kyun [1 ]
Huh, Hee Jae [1 ,3 ]
Lee, Nam Yong [1 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Lab Med & Genet, Seoul, South Korea
[2] Samsung Med Ctr, Smart Healthcare Res Inst, Biomed Engn Res Ctr, Seoul, South Korea
[3] Sungkyunkwan Univ, Samsung Adv Inst Hlth Sci & Technol, Dept Med Device Management & Res, Seoul, South Korea
[4] Samsung Med Ctr, Samsung Biomed Res Inst, Ctr Clin Med, Seoul, South Korea
关键词
antimicrobial resistance; antimicrobial susceptibility testing; bloodstream infections; broth microdilution; Gram-negative; positive blood culture broth; QMAC-dRAST; VITEK; 2; TURNAROUND TIME; VITEK-2; SYSTEM; IDENTIFICATION; ENTEROBACTERIACEAE; MORTALITY;
D O I
10.1002/jcla.25043
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Rapid antimicrobial susceptibility testing (AST) for bloodstream infections (BSIs) facilitates the optimization of antimicrobial therapy, preventing antimicrobial resistance and improving patient outcomes. QMAC-dRAST (QuantaMatrix Inc., Korea) is a rapid AST platform based on microfluidic chip technology that performs AST directly using positive blood culture broth (PBCB). This study evaluated the performance of QMAC-dRAST for Gram-negative bacteria using PBCB and subcultured colony isolates, comparing it with that of VITEK 2 (bioM & eacute;rieux, France) using broth microdilution (BMD) as the reference method. Methods We included 141 Gram-negative blood culture isolates from patients with BSI and 12 carbapenemase-producing clinical isolates of Enterobacterales spiked into blood culture bottles. QMAC-dRAST performance was evaluated using PBCB and colony isolates, whereas VITEK 2 and BMD were tested only on colony isolates. Results For PBCB, QMAC-dRAST achieved 92.1% categorical agreement (CA), 95.3% essential agreement (EA), with 1.8% very major errors (VMEs), 3.5% major errors (MEs), and 5.2% minor errors (mEs). With colony isolates, it exhibited 92.5% CA and 95.1% EA, with 2.0% VMEs, 3.2% MEs, and 4.8% mEs. VITEK 2 showed 94.1% CA and 96.0% EA, with 4.3% VMEs, 0.4% MEs, and 4.3% mEs. QMAC-dRAST yielded elevated error rates for specific antimicrobial agents, with high VMEs for carbapenems and aminoglycosides. The median time to result for QMAC-dRAST was 5.9 h for PBCB samples and 6.1 h for subcultured colony isolates. Conclusions The QMAC-dRAST system demonstrated considerable strengths and comparable performance to the VITEK 2 system; however, challenges were discerned with specific antimicrobial agents, underlining a necessity for improvement.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Evaluation of the Accelerate Pheno System for Fast Identification and Antimicrobial Susceptibility Testing from Positive Blood Cultures in Bloodstream Infections Caused by Gram-Negative Pathogens
    Marschal, Matthias
    Bachmaier, Johanna
    Autenrieth, Ingo
    Oberhettinger, Philipp
    Willmann, Matthias
    Peter, Silke
    JOURNAL OF CLINICAL MICROBIOLOGY, 2017, 55 (07) : 2116 - 2126
  • [42] Rapid phenotypic antimicrobial susceptibility testing of Gram-negative rods directly from positive blood cultures using the novel Q-linea ASTar system
    Esse, Jan
    Traeger, Johannes
    Valenza, Giuseppe
    Bogdan, Christian
    Held, Juergen
    JOURNAL OF CLINICAL MICROBIOLOGY, 2023, 61 (11)
  • [43] Comparative evaluation of the Vitek-2 Compact and Phoenix systems for rapid identification and antibiotic susceptibility testing directly from blood cultures of Gram-negative and Gram-positive isolates
    Gherardi, Giovanni
    Angeletti, Silvia
    Panitti, Miriam
    Pompilio, Arianna
    Di Bonaventura, Giovanni
    Crea, Francesca
    Avola, Alessandra
    Fico, Laura
    Palazzo, Carlo
    Sapia, Genoveffa Francesca
    Visaggio, Daniela
    Dicuonzo, Giordano
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2012, 72 (01) : 20 - 31
  • [44] Identification and antimicrobial susceptibility of gram-negative bacilli. Evaluation of the use of automatic system directly from blood culture bottles
    Alejandra Blanco, Maria
    Casimir, Lidia
    Angel Lopardo, Horacio
    ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2008, 42 (01): : 5 - 8
  • [45] Accuracy of Direct Antimicrobial Susceptibility Testing of Gram-Negative Bacteria from Positive Blood Cultures Using MicroScan System and Value of Using Expert Rules for β-Lactam Agents
    Jacobs, Michael R.
    Good, Caryn E.
    Abdelhamed, Ayman M.
    Bonomo, Robert A.
    ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2022, 66 (03)
  • [46] Rapid antimicrobial susceptibility testing by VITEK®2 directly from blood cultures in patients with Gram-negative rod bacteremia
    Hogan, C. A.
    Watz, N.
    Budvytiene, I.
    Banaei, N.
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2019, 94 (02) : 116 - 121
  • [47] Accuracy of the VITEK® 2 system for a rapid and direct identification and susceptibility testing of Gram-negative rods and Gram-positive cocci in blood samples
    Nimer, N. A.
    Al-Saa'da, R. J.
    Abuelaish, O.
    EASTERN MEDITERRANEAN HEALTH JOURNAL, 2016, 22 (03) : 193 - 200
  • [48] Evaluation of the LifeScale system for rapid phenotypic antimicrobial susceptibility testing from positive blood cultures
    Shebelut, Conrad
    Stern, Julia
    Grewal, Sarah
    Smith, Geoffrey
    Jaye, David
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2023, 160 : S137 - S138
  • [49] Evaluation of the LifeScale system for rapid phenotypic antimicrobial susceptibility testing from positive blood cultures
    Montelongo-Jauregui, Daniel
    Slechta, E. Susan
    Fisher, Mark
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2023, 160 : S137 - S138
  • [50] Multicenter evaluation of rapid antimicrobial susceptibility testing by VITEK®2 directly from positive blood culture
    Paluch, Maxime
    Lleres-Vadeboin, Manon
    Poupet, Helene
    Chanard, Emmanuel
    Wilhelm, Nathalie
    Nadji, Safia
    Prots, Laurence
    Bala, Yohann
    Zambardi, Gilles
    Cattoen, Christian
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2023, 106 (03)