Evaluation of the QMAC-dRAST System Version 2.5 for Rapid Antimicrobial Susceptibility Testing of Gram-Negative Bacteria From Positive Blood Culture Broth and Subcultured Colony Isolates

被引:2
|
作者
Kim, Tae Yeul [1 ]
Kang, Minhee [2 ,3 ]
Shim, Hyang Jin [4 ]
Kang, On-Kyun [1 ]
Huh, Hee Jae [1 ,3 ]
Lee, Nam Yong [1 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Lab Med & Genet, Seoul, South Korea
[2] Samsung Med Ctr, Smart Healthcare Res Inst, Biomed Engn Res Ctr, Seoul, South Korea
[3] Sungkyunkwan Univ, Samsung Adv Inst Hlth Sci & Technol, Dept Med Device Management & Res, Seoul, South Korea
[4] Samsung Med Ctr, Samsung Biomed Res Inst, Ctr Clin Med, Seoul, South Korea
关键词
antimicrobial resistance; antimicrobial susceptibility testing; bloodstream infections; broth microdilution; Gram-negative; positive blood culture broth; QMAC-dRAST; VITEK; 2; TURNAROUND TIME; VITEK-2; SYSTEM; IDENTIFICATION; ENTEROBACTERIACEAE; MORTALITY;
D O I
10.1002/jcla.25043
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Rapid antimicrobial susceptibility testing (AST) for bloodstream infections (BSIs) facilitates the optimization of antimicrobial therapy, preventing antimicrobial resistance and improving patient outcomes. QMAC-dRAST (QuantaMatrix Inc., Korea) is a rapid AST platform based on microfluidic chip technology that performs AST directly using positive blood culture broth (PBCB). This study evaluated the performance of QMAC-dRAST for Gram-negative bacteria using PBCB and subcultured colony isolates, comparing it with that of VITEK 2 (bioM & eacute;rieux, France) using broth microdilution (BMD) as the reference method. Methods We included 141 Gram-negative blood culture isolates from patients with BSI and 12 carbapenemase-producing clinical isolates of Enterobacterales spiked into blood culture bottles. QMAC-dRAST performance was evaluated using PBCB and colony isolates, whereas VITEK 2 and BMD were tested only on colony isolates. Results For PBCB, QMAC-dRAST achieved 92.1% categorical agreement (CA), 95.3% essential agreement (EA), with 1.8% very major errors (VMEs), 3.5% major errors (MEs), and 5.2% minor errors (mEs). With colony isolates, it exhibited 92.5% CA and 95.1% EA, with 2.0% VMEs, 3.2% MEs, and 4.8% mEs. VITEK 2 showed 94.1% CA and 96.0% EA, with 4.3% VMEs, 0.4% MEs, and 4.3% mEs. QMAC-dRAST yielded elevated error rates for specific antimicrobial agents, with high VMEs for carbapenems and aminoglycosides. The median time to result for QMAC-dRAST was 5.9 h for PBCB samples and 6.1 h for subcultured colony isolates. Conclusions The QMAC-dRAST system demonstrated considerable strengths and comparable performance to the VITEK 2 system; however, challenges were discerned with specific antimicrobial agents, underlining a necessity for improvement.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Evaluation of wider system for direct identification and antimicrobial susceptibility testing of gram-negative bacilli from positive blood culture bottles
    Fontanals, D
    Salceda, F
    Hernández, J
    Sanfeliu, I
    Torra, M
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2002, 21 (09) : 693 - 695
  • [12] EVALUATION OF THE COBAS-BACT SYSTEM FOR DIRECT AND RAPID IDENTIFICATION AND ANTIMICROBIAL SUSCEPTIBILITY TESTING OF GRAM-NEGATIVE RODS FROM POSITIVE BLOOD CULTURE BROTHS
    KAMM, W
    WENGER, A
    BILLE, J
    JOURNAL OF CLINICAL MICROBIOLOGY, 1989, 27 (01) : 102 - 105
  • [13] An Evaluation of the ASTar Automated Antimicrobial Testing System for Gram-Negative Bacteria in Positive Blood Cultures
    Coulson, Hannah
    Ivin, Angelo
    Day, Kathryn M.
    Fenwick, Danielle J. C.
    Marrs, Emma C. L.
    Mpwilu, Patrick
    Perry, John D.
    ANTIBIOTICS-BASEL, 2025, 14 (03):
  • [14] Identification and antimicrobial susceptibility testing of Gram-positive and Gram-negative bacteria from positive blood cultures using the Accelerate Pheno™ system
    Måns Ullberg
    Volkan Özenci
    European Journal of Clinical Microbiology & Infectious Diseases, 2020, 39 : 139 - 149
  • [15] Identification and antimicrobial susceptibility testing of Gram-positive and Gram-negative bacteria from positive blood cultures using the Accelerate Pheno™ system
    Ullberg, Mans
    Ozenci, Volkan
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2020, 39 (01) : 139 - 149
  • [16] QMAC-dRAST for the direct testing of antibiotic susceptibility for Enterobacterales in positive blood-culture broth: a comparison of the performances with the MicroScan system and direct disc diffusion testing methods (vol 78, pg 684, 2023)
    Gallois, E.
    Fihman, V
    Danjean, M.
    Gomart, C.
    Kimseng, H.
    Le Guen, R.
    Royer, G.
    Woerther, P. L.
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2023, 78 (04) : 1136 - 1136
  • [17] Evaluation of the Accelerate Pheno™ system for rapid identification and antimicrobial susceptibility testing of Gram-negative bacteria in bloodstream infections
    Descours, Ghislaine
    Desmurs, Laurent
    Thi Lam Thuy Hoang
    Ibranosyan, Marine
    Baume, Maud
    Ranc, Anne-Gaelle
    Fuhrmann, Christine
    Dauwalder, Olivier
    Salka, Wael
    Vandenesch, Francois
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2018, 37 (08) : 1573 - 1583
  • [18] Evaluation of the Accelerate Pheno™ system for rapid identification and antimicrobial susceptibility testing of Gram-negative bacteria in bloodstream infections
    Ghislaine Descours
    Laurent Desmurs
    Thi Lam Thuy Hoang
    Marine Ibranosyan
    Maud Baume
    Anne-Gaëlle Ranc
    Christine Fuhrmann
    Olivier Dauwalder
    Waël Salka
    François Vandenesch
    European Journal of Clinical Microbiology & Infectious Diseases, 2018, 37 : 1573 - 1583
  • [19] Direct inoculation of positive blood cultures using the Phoenix system for antimicrobial susceptibility testing of both Gram-positive and Gram-negative bacteria
    Florio, Walter
    Barnini, Simona
    Morici, Paola
    Lupetti, Antonella
    JOURNAL OF MEDICAL MICROBIOLOGY, 2015, 64 : 582 - 585
  • [20] Evaluation of the Merlin MICRONAUT system for rapid direct susceptibility testing of Gram-positive cocci and Gram-negative bacilli from positive blood cultures
    Wellinghausen, N.
    Pietzcker, T.
    Poppert, S.
    Belak, S.
    Fieser, N.
    Bartel, M.
    Essig, A.
    INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2007, 29 : S62 - S63