Intraoperative Laser Speckle Contrast Imaging to Assess Vessel Flow in Neurosurgery: A Pilot Study

被引:3
|
作者
Goldberg, Johannes [1 ,2 ]
Miller, David R. [3 ]
Dimanche, Alexis [2 ,4 ]
Kissling, Cedric [1 ,2 ]
Mueller, Timothy [1 ,2 ]
Mueller, Mandy D. [1 ,2 ]
Jesse, Christopher Marvin [1 ,2 ]
Murek, Michael [1 ,2 ]
Bervini, David [1 ,2 ]
Dunn, Andrew K. [4 ]
Raabe, Andreas [1 ,2 ]
机构
[1] Univ Bern, Bern Univ Hosp, Inselspital, Dept Neurosurg, Freiburgstr 16, CH-3010 Bern, Switzerland
[2] Univ Bern, Bern Univ Hosp, Inselspital, Stroke Res Ctr Bern, Freiburgstr 16, CH-3010 Bern, Switzerland
[3] Dynam Light Inc, Austin, TX USA
[4] Univ Texas Austin, Dept Biomed Engn, Austin, TX USA
关键词
Cerebral blood flow; Cerebrovascular neurosurgery; Laser speckle contrast imaging; Indocyanine green angiography; AGREEMENT;
D O I
10.1227/neu.0000000000002776
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND OBJECTIVES: Laser speckle contrast imaging (LSCI) has emerged as a promising tool for assessment of vessel flow during neurosurgery. We aimed to investigate the feasibility of visualizing vessel flow in the macrocirculation with a new fully microscope-integrated LSCI system and assess the validity and objectivity of findings compared with fluorescence angiography (FA). METHODS: This is a single-center prospective observational study enrolling adult patients requiring microsurgical treatment for brain vascular pathologies or brain tumors. Three independent raters, blinded toward findings of FA, reviewed regions of interest (ROIs) placed in exposed vessels and target structures. The primary end point was the validity of LSCI for assessment of vessel flow as measured by the agreement with FA. The secondary end point was objectivity, measured as the inter-rater agreement of LSCI findings. RESULTS: During 18 surgical procedures, 23 observations using FA and LSCI were captured simultaneously. Using LSCI, vessel flow was assessable in 62 (86.1%) and not assessable in 10 (13.9%) ROIs. The agreement between LSCI and FA was 86.1%, with an agreement coefficient of 0.85 (95% CI: 0.75-0.94). Disagreement between LSCI and FA was observed in the 10 ROIs that were not assessable. The agreement between ROIs that were assessable using LSCI and FA was 100%. The inter-rater agreement of LSCI findings was 87.9%, with an agreement coefficient of 0.86 (95% CI: 0.79-0.94). CONCLUSION: Fully microscope-integrated LSCI is feasible and has a high potential for clinical utility. Because of its characteristics, LSCI can be viewed as a full-field visual micro-Doppler that can be used as a complementary method to FA for assessing vessel flow during neurosurgery. Despite technical limitations related to the early development phase of the fully microscope-integrated system, we demonstrated reasonable validity and objectivity of findings compared with FA. Further research and refinement of the system may enhance its value in neurosurgical applications.
引用
收藏
页码:983 / 992
页数:10
相关论文
共 50 条
  • [21] Intraoperative Assessment of Parathyroid Viability using Laser Speckle Contrast Imaging
    E. A. Mannoh
    G. Thomas
    C. C. Solórzano
    A. Mahadevan-Jansen
    Scientific Reports, 7
  • [22] Intraoperative Assessment of Parathyroid Viability using Laser Speckle Contrast Imaging
    Mannoh, E. A.
    Thomas, G.
    Solorzano, C. C.
    Mahadevan-Jansen, A.
    SCIENTIFIC REPORTS, 2017, 7
  • [23] Intraoperative monitoring of cerebral blood flow by laser speckle contrast analysis
    Hecht, Nils
    Woitzik, Johannes
    Dreier, Jens P.
    Vajkoczy, Peter
    NEUROSURGICAL FOCUS, 2009, 27 (04) : E11.1 - E11.6
  • [24] Intraoperative real-time and continuous cerebral blood flow visualization with laser speckle contrast imaging
    Miller, David R.
    Ashour, Ramsey
    Sullender, Colin T.
    Dunn, Andrew K.
    CLINICAL AND TRANSLATIONAL NEUROPHOTONICS 2022, 2022, 11945
  • [25] Intraoperative laser speckle contrast imaging with retrospective motion correction for quantitative assessment of cerebral blood flow
    Richards, Lisa M.
    Towle, Erica L.
    Fox, Douglas J., Jr.
    Dunn, Andrew K.
    NEUROPHOTONICS, 2014, 1 (01)
  • [26] Study on blood-flow pulsation using laser speckle contrast imaging
    Yuan, Shuai
    Chen, Yu
    Preza, Chrysanthe
    Tang, Cha-Min
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS VIII, 2011, 7898
  • [27] Intraoperative Laser Speckle Contrast Imaging in DIEP Breast Reconstruction: A Prospective Case Series Study
    Zotterman, Johan
    Opsomer, Dries
    Farnebo, Simon
    Blondeel, Phillip
    Monstrey, Stan
    Tesselaar, Erik
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2020, 8 (01) : E2529
  • [28] Imaging Microvascular Flow Characteristics Using Laser Speckle Contrast Imaging
    Rege, Abhishek
    Murari, Kartikeya
    Li, Nan
    Thakor, Nitish V.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 1978 - 1981
  • [29] Laser Speckle Contrast Imaging on in vivo Blood Flow: a Review
    Li Chenxi
    Chen Wenliang
    Jiang Jingying
    Fan Ying
    Yang Jingzi
    Xu Kexin
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2018, 45 (02):
  • [30] Fluctuations of temporal contrast in laser speckle imaging of blood flow
    Hong, Jiachi
    Wang, Yang
    Chen, Xiao
    Lu, Jingling
    Li, Pengcheng
    OPTICS LETTERS, 2018, 43 (21) : 5214 - 5217