Intraoperative monitoring of cerebral blood flow by laser speckle contrast analysis

被引:101
|
作者
Hecht, Nils [1 ,2 ]
Woitzik, Johannes [1 ]
Dreier, Jens P. [2 ]
Vajkoczy, Peter [1 ,2 ]
机构
[1] Charite, Dept Neurosurg, D-13353 Berlin, Germany
[2] Charite, Ctr Stroke Res Berlin, D-13353 Berlin, Germany
关键词
cerebral blood flow; extracranial-intracranial bypass surgery; intraoperative cortical perfusion imaging; laser speckle contrast analysis; EXTRACRANIAL-INTRACRANIAL BYPASS; INDOCYANINE-GREEN VIDEOANGIOGRAPHY; OXYGEN-PRESSURE REACTIVITY; CEREBROVASCULAR AUTOREGULATION; DOPPLER FLOWMETRY; ANEURYSM SURGERY; SUBARACHNOID HEMORRHAGE; CORTICAL PERFUSION; GRAFT PATENCY; ANGIOGRAPHY;
D O I
10.3171/2009.8.FOCUS09148
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Currently, reliable low-cost and noninvasive techniques to assess cerebral perfusion in the operating room are not available. The authors report on their first clinical experience with laser speckle contrast analysis (LASCA) as a complementary imaging tool for the noninvasive and dynamic assessment of cerebral blood flow (CBF) during neurovascular surgery. The purpose of this preliminary study was to address the general feasibility of LASCA in terms of handling and image quality and to provide an example of its clinical implications. Methods. Laser speckle contrast analysis was performed in patients undergoing cerebral revascularization procedures for the treatment of hemodynamic compromise and complex aneurysms. The portable LASCA device was centered over the surgical field, and continuous 5-minute recordings of relative CBF were obtained. In the case of flow augmentation for hemodynamic compromise, CBF monitoring was performed before and after completion of the anastomosis. In the case of flow replacement for parent artery sacrifice, CBF monitoring was performed during consecutive 30-second test occlusions of the radial artery graft after proximal internal carotid artery sacrifice and the subsequent initiation of blood flow through the bypass. Results. In all cases, the authors achieved good visualization of relative CBF in addition to flow imaging in both the bypass graft and the cortical vasculature. During a sudden CBF decrease after test occlusion of the radial artery graft and subsequent flow initiation through the bypass, LASCA allowed immediate visualization and measurement of relative CBF in excellent spatiotemporal resolution. Conclusions. In this study LASCA offered noninvasive and rapid intraoperative assessment of relative CBF, which can be used for optimizing neurovascular procedures. (DOI: 10.3171/2009.8.FOCUS09148)
引用
收藏
页码:E11.1 / E11.6
页数:6
相关论文
共 50 条
  • [1] Laser Speckle Contrast Imaging for Intraoperative Monitoring of Cerebral Blood Flow
    Stavtsev D.D.
    Konovalov A.N.
    Blinova E.V.
    Piavchenko G.A.
    Golodnev G.E.
    Zalogin S.D.
    Gorina A.V.
    Lapin K.N.
    Vagner S.A.
    Grebenev F.V.
    Meglinski I.V.
    Gerasimenko A.Y.
    Telyshev D.V.
    Kuznetsov S.L.
    Bulletin of the Russian Academy of Sciences: Physics, 2022, 86 (Suppl 1): : S229 - S233
  • [2] Histogram analysis of laser speckle contrast image for cerebral blood flow monitoring
    Arkady SABDURASHITOV
    Vladislav VLYCHAGOV
    Olga ASINDEEVA
    Oxana VSEMYACHKINAGLUSHKOVSKAYA
    Valery VTUCHIN
    Frontiers of Optoelectronics, 2015, 8 (02) : 187 - 194
  • [3] Histogram analysis of laser speckle contrast image for cerebral blood flow monitoring
    Abdurashitov A.S.
    Lychagov V.V.
    Sindeeva O.A.
    Semyachkina-Glushkovskaya O.V.
    Tuchin V.V.
    Frontiers of Optoelectronics, 2015, 8 (2) : 187 - 194
  • [4] Laser Speckle Contrast Imaging of Cerebral Blood Flow
    Andrew K. Dunn
    Annals of Biomedical Engineering, 2012, 40 : 367 - 377
  • [5] Laser Speckle Contrast Imaging of Cerebral Blood Flow
    Dunn, Andrew K.
    ANNALS OF BIOMEDICAL ENGINEERING, 2012, 40 (02) : 367 - 377
  • [6] Intraoperative laser speckle contrast imaging for monitoring cerebral blood flow: results from a 10-patient pilot study
    Richards, Lisa M.
    Weber, Erica L.
    Parthasarathy, Ashwin B.
    Kappeler, Kaelyn L.
    Fox, Douglas J.
    Dunn, Andrew K.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS VIII, PTS 1 AND 2, 2012, 8207
  • [7] Cerebral blood flow analysis based on laser speckle contrast imaging technology
    Wu D.-D.
    Yao K.
    Guan K.-J.
    Fu W.-W.
    Sun J.-M.
    Guo Y.-B.
    Wang C.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2020, 28 (11): : 2411 - 2420
  • [8] Intraoperative real-time and continuous cerebral blood flow visualization with laser speckle contrast imaging
    Miller, David R.
    Ashour, Ramsey
    Sullender, Colin T.
    Dunn, Andrew K.
    CLINICAL AND TRANSLATIONAL NEUROPHOTONICS 2022, 2022, 11945
  • [9] Intraoperative laser speckle contrast imaging with retrospective motion correction for quantitative assessment of cerebral blood flow
    Richards, Lisa M.
    Towle, Erica L.
    Fox, Douglas J., Jr.
    Dunn, Andrew K.
    NEUROPHOTONICS, 2014, 1 (01)
  • [10] Capillary blood flow monitoring using laser speckle contrast analysis (LASCA)
    Briers, JD
    Richards, G
    He, XW
    JOURNAL OF BIOMEDICAL OPTICS, 1999, 4 (01) : 164 - 175