Intraoperative Laser Speckle Contrast Imaging to Assess Vessel Flow in Neurosurgery: A Pilot Study

被引:3
|
作者
Goldberg, Johannes [1 ,2 ]
Miller, David R. [3 ]
Dimanche, Alexis [2 ,4 ]
Kissling, Cedric [1 ,2 ]
Mueller, Timothy [1 ,2 ]
Mueller, Mandy D. [1 ,2 ]
Jesse, Christopher Marvin [1 ,2 ]
Murek, Michael [1 ,2 ]
Bervini, David [1 ,2 ]
Dunn, Andrew K. [4 ]
Raabe, Andreas [1 ,2 ]
机构
[1] Univ Bern, Bern Univ Hosp, Inselspital, Dept Neurosurg, Freiburgstr 16, CH-3010 Bern, Switzerland
[2] Univ Bern, Bern Univ Hosp, Inselspital, Stroke Res Ctr Bern, Freiburgstr 16, CH-3010 Bern, Switzerland
[3] Dynam Light Inc, Austin, TX USA
[4] Univ Texas Austin, Dept Biomed Engn, Austin, TX USA
关键词
Cerebral blood flow; Cerebrovascular neurosurgery; Laser speckle contrast imaging; Indocyanine green angiography; AGREEMENT;
D O I
10.1227/neu.0000000000002776
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND OBJECTIVES: Laser speckle contrast imaging (LSCI) has emerged as a promising tool for assessment of vessel flow during neurosurgery. We aimed to investigate the feasibility of visualizing vessel flow in the macrocirculation with a new fully microscope-integrated LSCI system and assess the validity and objectivity of findings compared with fluorescence angiography (FA). METHODS: This is a single-center prospective observational study enrolling adult patients requiring microsurgical treatment for brain vascular pathologies or brain tumors. Three independent raters, blinded toward findings of FA, reviewed regions of interest (ROIs) placed in exposed vessels and target structures. The primary end point was the validity of LSCI for assessment of vessel flow as measured by the agreement with FA. The secondary end point was objectivity, measured as the inter-rater agreement of LSCI findings. RESULTS: During 18 surgical procedures, 23 observations using FA and LSCI were captured simultaneously. Using LSCI, vessel flow was assessable in 62 (86.1%) and not assessable in 10 (13.9%) ROIs. The agreement between LSCI and FA was 86.1%, with an agreement coefficient of 0.85 (95% CI: 0.75-0.94). Disagreement between LSCI and FA was observed in the 10 ROIs that were not assessable. The agreement between ROIs that were assessable using LSCI and FA was 100%. The inter-rater agreement of LSCI findings was 87.9%, with an agreement coefficient of 0.86 (95% CI: 0.79-0.94). CONCLUSION: Fully microscope-integrated LSCI is feasible and has a high potential for clinical utility. Because of its characteristics, LSCI can be viewed as a full-field visual micro-Doppler that can be used as a complementary method to FA for assessing vessel flow during neurosurgery. Despite technical limitations related to the early development phase of the fully microscope-integrated system, we demonstrated reasonable validity and objectivity of findings compared with FA. Further research and refinement of the system may enhance its value in neurosurgical applications.
引用
收藏
页码:983 / 992
页数:10
相关论文
共 50 条
  • [31] Sensitivity of laser speckle contrast imaging to flow perturbations in the cortex
    Davis, Mitchell A.
    Gagnon, Louis
    Boas, David A.
    Dunn, Andrew K.
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (03): : 759 - 775
  • [32] Adaptive Feature Extraction for Blood Vessel Segmentation and Contrast Recalculation in Laser Speckle Contrast Imaging
    Morales-Vargas, Eduardo
    Padilla-Martinez, Juan Pablo
    Peregrina-Barreto, Hayde
    Garcia-Suastegui, Wendy Argelia
    Ramirez-San-Juan, Julio Cesar
    MICROMACHINES, 2022, 13 (10)
  • [33] Determination of the Flow Parameters of a Scattering Liquid in a Microfluidic Blood Vessel Phantom Based on Laser Speckle Contrast Imaging
    Galyastov, A. A.
    Stavtsev, D. D.
    Kozlov, I. O.
    Konovalov, A. N.
    Gerasimenko, A. Yu.
    Telyshev, D. V.
    BIOMEDICAL ENGINEERING, 2023, 57 (02) : 127 - 131
  • [34] Skin microdialysis coupled with Laser Speckle Contrast Imaging to assess microvascular reactivity
    Cracowski, J. L.
    Gaillard-Bigot, F.
    Cracowski, C.
    Roustit, M.
    Millet, C.
    MICROVASCULAR RESEARCH, 2011, 82 (03) : 333 - 338
  • [35] Skin microdialysis coupled with laser speckle contrast imaging to assess microvascular reactivity
    Cracowski, J. L.
    Gaillard-Bigot, F.
    Cracowski, C.
    Roustit, M.
    Millet, C.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2012, 26 : 65 - 66
  • [36] Excellent reproducibility of laser speckle contrast imaging to assess skin microvascular reactivity
    Roustit, M.
    Millet, C.
    Blaise, S.
    Dufournet, B.
    Cracowski, J. L.
    MICROVASCULAR RESEARCH, 2010, 80 (03) : 505 - 511
  • [37] Laser speckle contrast analysis in rheumatoid arthritis: a pilot study
    Vanden Bulcke, M.
    Vanhaecke, A.
    Deschepper, E.
    Cutolo, M.
    Jacques, P.
    Smith, V.
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2022, 40 (01) : 129 - 134
  • [38] Laser speckle contrast imaging and laser Doppler flowmetry reproducibly assess reflex cutaneous vasoconstriction
    Schwartz, Kelsey S.
    Theis, Emma N.
    Bunting, Kearsten
    McCaughey, Rebecca A.
    Lang, James A.
    MICROVASCULAR RESEARCH, 2022, 142
  • [39] Laser Speckle Imaging for Retinopathy of Prematurity: A Pilot Study
    Alexander, Janet
    Sinha, Avigyan
    Balasubramanian, Tara
    Sidelnikov, Danielle
    Shats, Daniel
    Das, Urjita
    Forbes, Grace
    Williams, Kristin
    Levin, Moran
    Rege, Abhishek
    Saeedi, Osamah
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [40] Choosing a laser for laser speckle contrast imaging
    Dmitry D. Postnov
    Xiaojun Cheng
    Sefik Evren Erdener
    David A. Boas
    Scientific Reports, 9