User-friendly diameter-based measurement paper sensor for chloride detection in water

被引:2
|
作者
Tasangtong, Benjarat [1 ]
Pholsaptanakorn, Thanapit [2 ,3 ]
Tapsawut, Thanakorn [2 ,3 ]
Wiwekwin, Nisakorn [4 ]
Mettakoonpitak, Jaruwan [5 ]
Nongkhai, Piyaporn Na [2 ,3 ,6 ]
Sameenoi, Yupaporn [2 ,3 ,6 ]
机构
[1] Innosens 2021 Co Ltd, 99-22M 6, Muang 20000, Chon Buri, Thailand
[2] Burapha Univ, Fac Sci, Ctr Excellence Innovat Chem, Dept Chem, Chon Buri 20131, Thailand
[3] Burapha Univ, Fac Sci, Ctr Excellence Innovat Chem, Chon Buri 20131, Thailand
[4] Saensuk Municipal, Chon Buri 20130, Thailand
[5] Rambhai Barni Rajabhat Univ, Fac Sci & Technol, Dept Chem, Chanthaburi 22000, Thailand
[6] Burapha Univ, Res Unit Sensor Innovat RUSI, Chon Buri 20131, Thailand
来源
TALANTA OPEN | 2024年 / 9卷
关键词
Chloride in water; Paper sensor; Diameter -based measurement; On -site analysis; Paper -based device; ION; TITRATION; PH;
D O I
10.1016/j.talo.2024.100305
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Chloride (Cl-) is an anion widely distributed in nature. It is also an essential parameter to consider when assessing the water quality for ensuring drinking water safety, preventing infrastructure damage, mitigating environmental impact, identifying groundwater contamination. This work presents the first development of a diameter-based measurement paper sensor for chloride analysis using the reaction based on a Mohr's precipitation titration. The paper sensor that has a circular shape with 3-cm diameter was pre-coated with AgNO3 and CrO42- forming brown precipitates of the Ag2CrO4. The sensor was sealed using lamination films with 3-mm diameter hole-punched inlets on the top of the lamination film for sample delivery. To detect chloride, the sensor was simply immersed into the sample. The chloride solution flows into the central sample inlet and spreads radially to undergo the displacement reaction with Ag2CrO4 precipitate, forming AgCl white precipitate whose diameter proportional to the chloride that can be observed within 3 min. Concentration of AgNO3 used was found to impact the analytical figures of merit. The lower AgNO3 concentration yields lower limit of detection, narrower linear range but higher sensitivity. The sensor was applied for chloride analysis in tap water, drinking water and industrial water and the chloride concentration obtained from the developed sensors are not significant differences from those obtained from the standard titration method at 95% confidence interval (two tailed P = 0.08) indicating that the developed sensor provides accurate analysis of chloride in water samples from various sources. The developed sensor was used by the untrained staffs for on-site of analysis chloride in tap water collected at 26 locations in SaenSuk Municipality area, Chonburi, Thailand. The results showed that the chloride level in all samples is in range of 52.2-84.7 mg L-1 which is far below the acceptable range set by the Provincial Waterwork Authority of Thailand (< 250 mg L-1) indicating that the tap water used in this area is safe for consumers.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Development of user-friendly software for the roughness measurement of ultra smooth surface
    Li, HY
    Li, YH
    Li, QX
    Liao, XH
    Zheng, JL
    2ND INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, PTS 1 AND 2, 2006, 6150
  • [42] User-friendly one-step disposable signal-on bioassay for glyphosate detection in water samples
    Delprat, N.
    Martins, L. O.
    Blum, L. J.
    Aymard, C. M. G.
    Leca-Bouvier, a B.
    Octobre, G.
    Doumeche, B.
    BIOSENSORS & BIOELECTRONICS, 2023, 241
  • [43] User-friendly point of care test device for detection of arsenic in potable water: Prototype, design, and artifact
    Ravula, Rajasekhar
    Bhabak, Krishna Pada
    Mandal, Tapas K.
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2022, 17 (05)
  • [44] MetaAnalyst: a user-friendly tool for metagenomic biomarker detection and phenotype classification
    Mustafa Alshawaqfeh
    Salahelden Rababah
    Abdullah Hayajneh
    Ammar Gharaibeh
    Erchin Serpedin
    BMC Medical Research Methodology, 22
  • [45] Rational Design of a User-Friendly Aptamer/Peptide-Based Device for the Detection ofStaphylococcus aureus
    Ronda, Luca
    Tonelli, Alessandro
    Sogne, Elisa
    Autiero, Ida
    Spyrakis, Francesca
    Pellegrino, Sara
    Abbiati, Giorgio
    Maffioli, Elisa
    Schulte, Carsten
    Piano, Riccardo
    Cozzini, Pietro
    Mozzarelli, Andrea
    Bettati, Stefano
    Clerici, Francesca
    Milani, Paolo
    Lenardi, Cristina
    Tedeschi, Gabriella
    Gelmi, Maria Luisa
    SENSORS, 2020, 20 (17) : 1 - 22
  • [46] Predictive Framework Development for User-Friendly On-Site Glucose Detection
    Kishnani, Vinay
    Gupta, Ankur
    ACS APPLIED BIO MATERIALS, 2023, 6 (10) : 4336 - 4344
  • [47] A novel user-friendly tool for minimizing water use in processing industry
    Nemati-Amirkolaii, Keivan
    Romdhana, Hedi
    Lameloise, Marie-Laure
    CLEANER ENGINEERING AND TECHNOLOGY, 2021, 4
  • [48] Message-In-a-Bottle: User-Friendly and Secure Key Deployment for Sensor Nodes
    Kuo, Cynthia
    Luk, Mark
    Negi, Rohit
    Perrig, Adrian
    SENSYS'07: PROCEEDINGS OF THE 5TH ACM CONFERENCE ON EMBEDDED NETWORKED SENSOR SYSTEMS, 2007, : 233 - 246
  • [49] Towards a Lightweight Security Solution for User-Friendly Management of Distributed Sensor Networks
    Tarvainen, Pentti
    Ala-Louko, Mikko
    Jaakola, Marko
    Uusitalo, Ilkka
    Lalis, Spyros
    Paczesny, Tomasz
    Taumberger, Markus
    Savolainen, Pekka
    SMART SPACES AND NEXT GENERATION WIRED/WIRELESS NETWORKING, PROCEEDINGS, 2009, 5764 : 97 - +
  • [50] A user-friendly fluorescent biosensor for precise lactate detection and quantification in vitro
    Wang, Qiwei
    Shi, Sai
    Liu, Si
    Ye, Sheng
    CHEMICAL COMMUNICATIONS, 2024, 60 (88) : 12884 - 12887