User-friendly diameter-based measurement paper sensor for chloride detection in water

被引:2
|
作者
Tasangtong, Benjarat [1 ]
Pholsaptanakorn, Thanapit [2 ,3 ]
Tapsawut, Thanakorn [2 ,3 ]
Wiwekwin, Nisakorn [4 ]
Mettakoonpitak, Jaruwan [5 ]
Nongkhai, Piyaporn Na [2 ,3 ,6 ]
Sameenoi, Yupaporn [2 ,3 ,6 ]
机构
[1] Innosens 2021 Co Ltd, 99-22M 6, Muang 20000, Chon Buri, Thailand
[2] Burapha Univ, Fac Sci, Ctr Excellence Innovat Chem, Dept Chem, Chon Buri 20131, Thailand
[3] Burapha Univ, Fac Sci, Ctr Excellence Innovat Chem, Chon Buri 20131, Thailand
[4] Saensuk Municipal, Chon Buri 20130, Thailand
[5] Rambhai Barni Rajabhat Univ, Fac Sci & Technol, Dept Chem, Chanthaburi 22000, Thailand
[6] Burapha Univ, Res Unit Sensor Innovat RUSI, Chon Buri 20131, Thailand
来源
TALANTA OPEN | 2024年 / 9卷
关键词
Chloride in water; Paper sensor; Diameter -based measurement; On -site analysis; Paper -based device; ION; TITRATION; PH;
D O I
10.1016/j.talo.2024.100305
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Chloride (Cl-) is an anion widely distributed in nature. It is also an essential parameter to consider when assessing the water quality for ensuring drinking water safety, preventing infrastructure damage, mitigating environmental impact, identifying groundwater contamination. This work presents the first development of a diameter-based measurement paper sensor for chloride analysis using the reaction based on a Mohr's precipitation titration. The paper sensor that has a circular shape with 3-cm diameter was pre-coated with AgNO3 and CrO42- forming brown precipitates of the Ag2CrO4. The sensor was sealed using lamination films with 3-mm diameter hole-punched inlets on the top of the lamination film for sample delivery. To detect chloride, the sensor was simply immersed into the sample. The chloride solution flows into the central sample inlet and spreads radially to undergo the displacement reaction with Ag2CrO4 precipitate, forming AgCl white precipitate whose diameter proportional to the chloride that can be observed within 3 min. Concentration of AgNO3 used was found to impact the analytical figures of merit. The lower AgNO3 concentration yields lower limit of detection, narrower linear range but higher sensitivity. The sensor was applied for chloride analysis in tap water, drinking water and industrial water and the chloride concentration obtained from the developed sensors are not significant differences from those obtained from the standard titration method at 95% confidence interval (two tailed P = 0.08) indicating that the developed sensor provides accurate analysis of chloride in water samples from various sources. The developed sensor was used by the untrained staffs for on-site of analysis chloride in tap water collected at 26 locations in SaenSuk Municipality area, Chonburi, Thailand. The results showed that the chloride level in all samples is in range of 52.2-84.7 mg L-1 which is far below the acceptable range set by the Provincial Waterwork Authority of Thailand (< 250 mg L-1) indicating that the tap water used in this area is safe for consumers.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] QualitySNPng: a user-friendly SNP detection and visualization tool
    Nijveen, Harm
    van Kaauwen, Martijn
    Esselink, Danny G.
    Hoegen, Brechtje
    Vosman, Ben
    NUCLEIC ACIDS RESEARCH, 2013, 41 (W1) : W587 - W590
  • [22] A User-Friendly and Sustainable Toilet Based on Vermicomposting
    Alonso-Marroquin, Fernando
    Qadir, Ghulam
    Nazha, Jad
    Pino, Vanessa
    Brambilla, Arianna
    SUSTAINABILITY, 2023, 15 (16)
  • [23] Multichannel Protocols for User-Friendly and Scalable Initialization of Sensor Networks
    Perkovic, Toni
    Stancic, Ivo
    Malisa, Luka
    Cagalj, Mario
    SECURITY AND PRIVACY IN COMMUNICATION NETWORKS, 2009, 19 : 228 - 247
  • [24] An Index for User-Friendly Proximal Detection of Water Requirements to Optimized Irrigation Management in Vineyards
    Fernandes de Oliveira, Ana
    Mameli, Massimiliano Giuseppe
    Lo Cascio, Mauro
    Sirca, Costantino
    Satta, Daniela
    AGRONOMY-BASEL, 2021, 11 (02):
  • [25] Development of deep learning based user-friendly interface for fruit quality detection
    Ali, Maimunah Mohd
    Hashim, Norhashila
    JOURNAL OF FOOD ENGINEERING, 2024, 380
  • [26] A user-friendly method for calibrating a subcutaneous glucose sensor-based hypoglycaemic alarm
    Aussedat, B
    Thome-Duret, V
    Reach, G
    Lemmonier, F
    Klein, JC
    Hu, Y
    Wilson, GS
    BIOSENSORS & BIOELECTRONICS, 1997, 12 (11): : 1061 - 1071
  • [27] A User-Friendly Application to Automate CT Renal Stone Measurement
    Ziemba, Justin B.
    Li, Pan
    Gurnani, Rishab
    Kawamoto, Satomi
    Fishman, Elliot
    Fung, George
    Ludwig, Wesley W.
    Stoianovici, Dan
    Matlaga, Brian R.
    JOURNAL OF ENDOUROLOGY, 2018, 32 (08) : 685 - 691
  • [28] Diameter-based inkjet-printed paper devices for formaldehyde analysis in foods
    Tasangtong, Benjarat
    Henry, Charles S.
    Sameenoi, Yupaporn
    FOOD CONTROL, 2023, 145
  • [29] User-friendly fault detection method for building chilled water flowmeters: Field data validation
    Qiu, Shunian
    Li, Zhenhai
    He, Ruikai
    Li, Zhengwei
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2022, 28 (09) : 1116 - 1137
  • [30] Make computer-based training user-friendly
    Ferrell, DK
    DeBord, CL
    JOURNAL OF NURSING ADMINISTRATION, 2003, : 30 - 31