User-friendly diameter-based measurement paper sensor for chloride detection in water

被引:2
|
作者
Tasangtong, Benjarat [1 ]
Pholsaptanakorn, Thanapit [2 ,3 ]
Tapsawut, Thanakorn [2 ,3 ]
Wiwekwin, Nisakorn [4 ]
Mettakoonpitak, Jaruwan [5 ]
Nongkhai, Piyaporn Na [2 ,3 ,6 ]
Sameenoi, Yupaporn [2 ,3 ,6 ]
机构
[1] Innosens 2021 Co Ltd, 99-22M 6, Muang 20000, Chon Buri, Thailand
[2] Burapha Univ, Fac Sci, Ctr Excellence Innovat Chem, Dept Chem, Chon Buri 20131, Thailand
[3] Burapha Univ, Fac Sci, Ctr Excellence Innovat Chem, Chon Buri 20131, Thailand
[4] Saensuk Municipal, Chon Buri 20130, Thailand
[5] Rambhai Barni Rajabhat Univ, Fac Sci & Technol, Dept Chem, Chanthaburi 22000, Thailand
[6] Burapha Univ, Res Unit Sensor Innovat RUSI, Chon Buri 20131, Thailand
来源
TALANTA OPEN | 2024年 / 9卷
关键词
Chloride in water; Paper sensor; Diameter -based measurement; On -site analysis; Paper -based device; ION; TITRATION; PH;
D O I
10.1016/j.talo.2024.100305
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Chloride (Cl-) is an anion widely distributed in nature. It is also an essential parameter to consider when assessing the water quality for ensuring drinking water safety, preventing infrastructure damage, mitigating environmental impact, identifying groundwater contamination. This work presents the first development of a diameter-based measurement paper sensor for chloride analysis using the reaction based on a Mohr's precipitation titration. The paper sensor that has a circular shape with 3-cm diameter was pre-coated with AgNO3 and CrO42- forming brown precipitates of the Ag2CrO4. The sensor was sealed using lamination films with 3-mm diameter hole-punched inlets on the top of the lamination film for sample delivery. To detect chloride, the sensor was simply immersed into the sample. The chloride solution flows into the central sample inlet and spreads radially to undergo the displacement reaction with Ag2CrO4 precipitate, forming AgCl white precipitate whose diameter proportional to the chloride that can be observed within 3 min. Concentration of AgNO3 used was found to impact the analytical figures of merit. The lower AgNO3 concentration yields lower limit of detection, narrower linear range but higher sensitivity. The sensor was applied for chloride analysis in tap water, drinking water and industrial water and the chloride concentration obtained from the developed sensors are not significant differences from those obtained from the standard titration method at 95% confidence interval (two tailed P = 0.08) indicating that the developed sensor provides accurate analysis of chloride in water samples from various sources. The developed sensor was used by the untrained staffs for on-site of analysis chloride in tap water collected at 26 locations in SaenSuk Municipality area, Chonburi, Thailand. The results showed that the chloride level in all samples is in range of 52.2-84.7 mg L-1 which is far below the acceptable range set by the Provincial Waterwork Authority of Thailand (< 250 mg L-1) indicating that the tap water used in this area is safe for consumers.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Rapid, user-friendly, and inexpensive detection of azidothymidine
    Luo, Ying
    Jia, Tianwei
    Fang, Jieqiong
    Liu, Dandan
    Saikam, Varma
    Sheng, Xiaolin
    Iyer, Suri S.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (07) : 1999 - 2006
  • [12] Cost-effective, user-friendly detection and preconcentration of thrombin on a sustainable paper-based electrochemical platform
    Raucci, Ada
    Sorrentino, Giuseppina
    Singh, Sima
    Borbone, Nicola
    Oliviero, Giorgia
    Piccialli, Gennaro
    Terracciano, Monica
    Cinti, Stefano
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2025, 417 (09) : 1863 - 1872
  • [13] Capillary Flow-Driven Microfluidics Combined with a Paper Device for Fast User-Friendly Detection of Heavy Metals in Water
    Aryal, Prakash
    Brack, Eric
    Alexander, Todd
    Henry, Charles S.
    ANALYTICAL CHEMISTRY, 2023, 95 (13) : 5820 - 5827
  • [14] Sensor Network-Based and User-Friendly User Location Discovery for Future Smart Homes
    Ahvar, Ehsan
    Lee, Gyu Myoung
    Han, Son N.
    Crespi, Noel
    Khan, Imran
    SENSORS, 2016, 16 (07)
  • [15] Tablet-Based Sensor: A Stable and User-Friendly Tool for Point-of-Care Detection of Glucose in Urine
    Hajimiri, Hasti
    Tali, Seyed Hamid Safiabadi
    Al-Kassawneh, Muna
    Sadiq, Zubi
    Jahanshahi-Anbuhi, Sana
    BIOSENSORS-BASEL, 2023, 13 (09):
  • [16] Machine vision offers user-friendly error detection
    Van Belle, M
    PHOTONICS SPECTRA, 1998, 32 (12) : 118 - +
  • [17] User-friendly smartphone detection of middle ear fluid
    Sabharwal, Vishakha
    Pelton, Stephen I.
    JOURNAL OF PEDIATRICS, 2020, 220 : 264 - 265
  • [18] Machine vision offers user-friendly error detection
    Photonics Spectra, 12 (118):
  • [19] Validity Of A Joint Diameter-based System For The Measurement Of Body Composition
    Barnes, Jeremy T.
    Wagganer, Jason D.
    Loenneke, Jeremy P.
    Miller, William M.
    Abdul, Majid Mufaqam Syed
    Soni, Dhwani S.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 41 - 41
  • [20] A USER-FRIENDLY ARCHITECTURE BASED ON CORPORATE CONFIDENCE
    Suh, Eulho
    Chanjoong, Kim
    SPACE, 2014, (554): : 34 - 41