User-friendly diameter-based measurement paper sensor for chloride detection in water

被引:2
|
作者
Tasangtong, Benjarat [1 ]
Pholsaptanakorn, Thanapit [2 ,3 ]
Tapsawut, Thanakorn [2 ,3 ]
Wiwekwin, Nisakorn [4 ]
Mettakoonpitak, Jaruwan [5 ]
Nongkhai, Piyaporn Na [2 ,3 ,6 ]
Sameenoi, Yupaporn [2 ,3 ,6 ]
机构
[1] Innosens 2021 Co Ltd, 99-22M 6, Muang 20000, Chon Buri, Thailand
[2] Burapha Univ, Fac Sci, Ctr Excellence Innovat Chem, Dept Chem, Chon Buri 20131, Thailand
[3] Burapha Univ, Fac Sci, Ctr Excellence Innovat Chem, Chon Buri 20131, Thailand
[4] Saensuk Municipal, Chon Buri 20130, Thailand
[5] Rambhai Barni Rajabhat Univ, Fac Sci & Technol, Dept Chem, Chanthaburi 22000, Thailand
[6] Burapha Univ, Res Unit Sensor Innovat RUSI, Chon Buri 20131, Thailand
来源
TALANTA OPEN | 2024年 / 9卷
关键词
Chloride in water; Paper sensor; Diameter -based measurement; On -site analysis; Paper -based device; ION; TITRATION; PH;
D O I
10.1016/j.talo.2024.100305
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Chloride (Cl-) is an anion widely distributed in nature. It is also an essential parameter to consider when assessing the water quality for ensuring drinking water safety, preventing infrastructure damage, mitigating environmental impact, identifying groundwater contamination. This work presents the first development of a diameter-based measurement paper sensor for chloride analysis using the reaction based on a Mohr's precipitation titration. The paper sensor that has a circular shape with 3-cm diameter was pre-coated with AgNO3 and CrO42- forming brown precipitates of the Ag2CrO4. The sensor was sealed using lamination films with 3-mm diameter hole-punched inlets on the top of the lamination film for sample delivery. To detect chloride, the sensor was simply immersed into the sample. The chloride solution flows into the central sample inlet and spreads radially to undergo the displacement reaction with Ag2CrO4 precipitate, forming AgCl white precipitate whose diameter proportional to the chloride that can be observed within 3 min. Concentration of AgNO3 used was found to impact the analytical figures of merit. The lower AgNO3 concentration yields lower limit of detection, narrower linear range but higher sensitivity. The sensor was applied for chloride analysis in tap water, drinking water and industrial water and the chloride concentration obtained from the developed sensors are not significant differences from those obtained from the standard titration method at 95% confidence interval (two tailed P = 0.08) indicating that the developed sensor provides accurate analysis of chloride in water samples from various sources. The developed sensor was used by the untrained staffs for on-site of analysis chloride in tap water collected at 26 locations in SaenSuk Municipality area, Chonburi, Thailand. The results showed that the chloride level in all samples is in range of 52.2-84.7 mg L-1 which is far below the acceptable range set by the Provincial Waterwork Authority of Thailand (< 250 mg L-1) indicating that the tap water used in this area is safe for consumers.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Practical and user-friendly procedure for Michael reactions of α-nitroketones in water
    Miranda, S
    López-Alvarado, P
    Giorgi, G
    Rodriguez, J
    Avendaño, C
    Menéndez, JC
    SYNLETT, 2003, (14) : 2159 - 2162
  • [32] A user-friendly CAPTCHA scheme based on usability features
    Pakdel, R., 1600, Asian Network for Scientific Information (12):
  • [33] Pixel-counting sensor provides easy, user-friendly setup
    Labs, W
    I&CS-INSTRUMENTATION & CONTROL SYSTEMS, 2000, 73 (01): : 63 - 63
  • [34] A user-friendly video camera based on ergonomic studies
    Iijima, Yasuhiro
    Hatanaka, Haruo
    Fujita, Hideto
    Shimomura, Yoshihiro
    Katsuura, Tetsuo
    2008 DIGEST OF TECHNICAL PAPERS INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS, 2008, : 388 - +
  • [35] A Comparison Of DXA And A Joint Diameter-based System For The Measurement Of Body Composition
    Barnes, Jeremy T.
    Wagganer, Jason D.
    Loenneke, Jeremy P.
    Miller, William P.
    Gegg, Chelsey
    McDowell, Kurt W.
    Schrum, Lucas K.
    Barns, Kelly D.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 259 - 260
  • [36] A Comparison Of DXA And A Joint Diameter-based System For The Measurement Of Body Composition
    Barnes, Jeremy T.
    Wagganer, Jason D.
    Loenneke, Jeremy P.
    Miller, William P.
    Gegg, Chelsey
    McDowell, Kurt W.
    Schrum, Lucas K.
    Barns, Kelly D.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 259 - 260
  • [37] IoT BASED SOIL MOISTURE MANAGEMENT USING CAPACITIVE SENSOR AND USER-FRIENDLY SMARTPHONE APPLICATION
    Sarmphim, Pharunee
    Sutthiphon, Narongsak
    Jaroensong, Parimate
    Sirisathitkul, Chitnarong
    Sirisathitkul, Yaowarat
    INMATEH-AGRICULTURAL ENGINEERING, 2022, 66 (01): : 159 - 166
  • [38] STOCK: A User-Friendly Stock Prediction and Sentiment Analysis System (Demonstration Paper)
    Balliu, Ilda
    Cerim, Harun
    Emeiri, Mahran
    Yos, Kaan
    Holubova, Irena
    RESEARCH CHALLENGES IN INFORMATION SCIENCE (RCIS 2021), 2021, 415 : 575 - 580
  • [39] Nebulizer calibration using lithium chloride: an accurate, reproducible and user-friendly method
    Ward, RJ
    Reid, DW
    Leonard, RF
    Johns, DP
    Walters, EH
    EUROPEAN RESPIRATORY JOURNAL, 1998, 11 (04) : 937 - 941
  • [40] In-situ measurement of the water vapor concentration in industrial ovens by an user-friendly semiconductor laser system
    Kohns, P
    Stormann, R
    Budzynski, E
    Walter, N
    Knoop, J
    Kuster, R
    OPTICAL INSPECTION AND MICROMEASUREMENTS II, 1997, 3098 : 544 - 551