Visual Loop-Mediated Isothermal Amplification (LAMP) Assay for Rapid On-Site Detection of Escherichia coli O157: H7 in Milk Products

被引:1
|
作者
Cui, Shuangshuang [1 ,2 ]
Wei, Yong [3 ]
Li, Can [1 ,2 ]
Zhang, Jian [1 ,2 ,4 ]
Zhao, Yunfeng [1 ,2 ]
Peng, Xiayu [5 ]
Sun, Fengxia [1 ,2 ,5 ]
机构
[1] Shihezi Univ, Sch Food Sci & Technol, Shihezi 832000, Peoples R China
[2] Shihezi Univ, Sch Food Sci & Technol, Key Lab Food Nutr & Safety Control Xinjiang Prod &, Shihezi 832000, Peoples R China
[3] Xinjiang Tianrun Dairy Co Ltd, Wuchang Rd 2702, Urumqi 830000, Peoples R China
[4] Shihezi Univ, Sch Food Sci & Technol, Key Lab Agr Prod Proc & Qual Control Specialty Coc, Shihezi 832000, Peoples R China
[5] Shihezi Univ, Coll Anim Sci & Technol, Shihezi 832000, Peoples R China
基金
中国国家自然科学基金;
关键词
loop-mediated isothermal amplification; Escherichia coli O157:H7; visualization detection; immunochromatographic test strips; colorimetric method; ESCHERICHIA-COLI O157H7;
D O I
10.3390/foods13132143
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
(1) Background: Rapid on-site testing is an effective method for the detection of Escherichia coli O157: H7(E. coli O157: H7) in food ingredients and the environment. (2) Methods: In this study, we developed colorimetric loop-mediated isothermal amplification (LAMP) and immunochromatographic test strips (ICTs) for the rapid and visual detection of E. coli O157: H7. This study designed new specific LAMP primers for E. coli O157: H7 virulence island genes. After the LAMP amplification, the double-stranded DNA target sequence labeled with digoxin and fluorescein isothiocyanate (FITC) at both ends was bound to the anti-digoxin antibody on the gold nanoparticles. Subsequently, it was further bound to the anti-FITC antibody at the T line of the ICTs, forming a positive test result. Hydroxynaphthyl blue dye was directly added to the LAMP amplification product. A blue color indicated positive results, while a purple color indicated negative results. (3) Results: Two visualization methods showed high specificity for the target strains. The visualization tests had sensitivities of 5.7 CFU mL(-1), and the detection limit of the Escherichia coli O157: H7 in artificially contaminated milk samples was 5.7 x 10(2) CFU mL(-1), which was consistent with the results of the standard method (LAMP-electrophoresis method) used in commercial inspection. (4) Conclusions: Both methods could be useful in remote and under-resourced areas.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Development of a loop-mediated isothermal amplification (LAMP) assay for rapid and visual detection of Anguillid herpesvirus 1
    Chen, Qiang
    Zhang, Li-Juan
    Song, Tie-Ying
    Ge, Jun-Qing
    JOURNAL OF VIROLOGICAL METHODS, 2024, 330
  • [42] QCM immunosensor with nanoparticle amplification for detection of Escherichia coli O157:H7
    Fei Liu
    Yanbin Li
    Xiao-Li Su
    Michael F. Slavik
    Yibin Ying
    Jianping Wang
    Sensing and Instrumentation for Food Quality and Safety, 2007, 1 (4): : 161 - 168
  • [43] Escherichia coli O157:H7
    Weir, E
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2000, 163 (02) : 205 - 205
  • [44] Establishment of real-time fluorescence and visual LAMP for rapid detection of Escherichia coli O157:H7 and kits construction
    Wang, Zuwei
    Cui, Xinping
    Hu, Antuo
    Lu, Zhaoxin
    Meng, Fanqiang
    Zhou, Libang
    Bie, Xiaomei
    LETTERS IN APPLIED MICROBIOLOGY, 2023, 76 (11)
  • [45] Escherichia coli O157:H7
    Hartigan, PJ
    IRISH VETERINARY JOURNAL, 1997, 50 (02) : 91 - +
  • [46] Escherichia coli O157:H7
    Riemann, HP
    Cliver, DO
    VETERINARY CLINICS OF NORTH AMERICA-FOOD ANIMAL PRACTICE, 1998, 14 (01) : 41 - +
  • [47] Escherichia coli O157:H7
    Mead, PS
    Griffin, PM
    LANCET, 1998, 352 (9135): : 1207 - 1212
  • [48] Dramatically Enhanced Immunochromatographic Assay Using Cascade Signal Amplification for Ultrasensitive Detection of Escherichia coli O157:H7 in Milk
    Fu, Jinmei
    Zhou, Yaofeng
    Huang, Xiaolin
    Zhang, Wenjing
    Wu, Yuhao
    Fang, Hao
    Zhang, Cunzheng
    Xiong, Yonghua
    Journal of Agricultural and Food Chemistry, 2020, 68 (04): : 1118 - 1125
  • [49] On-site detection of Pythium ultimum in potatoes using loop-mediated isothermal amplification (LAMP)
    Woodhall, J.
    Wharton, P.
    Dangi, S.
    Perkins, K.
    Azcona, J.
    PHYTOPATHOLOGY, 2016, 106 (12) : 116 - 116
  • [50] Escherichia coli O157:H7
    Tarr, PI
    Neill, MA
    GASTROENTEROLOGY CLINICS OF NORTH AMERICA, 2001, 30 (03) : 735 - +