Visual Loop-Mediated Isothermal Amplification (LAMP) Assay for Rapid On-Site Detection of Escherichia coli O157: H7 in Milk Products

被引:1
|
作者
Cui, Shuangshuang [1 ,2 ]
Wei, Yong [3 ]
Li, Can [1 ,2 ]
Zhang, Jian [1 ,2 ,4 ]
Zhao, Yunfeng [1 ,2 ]
Peng, Xiayu [5 ]
Sun, Fengxia [1 ,2 ,5 ]
机构
[1] Shihezi Univ, Sch Food Sci & Technol, Shihezi 832000, Peoples R China
[2] Shihezi Univ, Sch Food Sci & Technol, Key Lab Food Nutr & Safety Control Xinjiang Prod &, Shihezi 832000, Peoples R China
[3] Xinjiang Tianrun Dairy Co Ltd, Wuchang Rd 2702, Urumqi 830000, Peoples R China
[4] Shihezi Univ, Sch Food Sci & Technol, Key Lab Agr Prod Proc & Qual Control Specialty Coc, Shihezi 832000, Peoples R China
[5] Shihezi Univ, Coll Anim Sci & Technol, Shihezi 832000, Peoples R China
基金
中国国家自然科学基金;
关键词
loop-mediated isothermal amplification; Escherichia coli O157:H7; visualization detection; immunochromatographic test strips; colorimetric method; ESCHERICHIA-COLI O157H7;
D O I
10.3390/foods13132143
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
(1) Background: Rapid on-site testing is an effective method for the detection of Escherichia coli O157: H7(E. coli O157: H7) in food ingredients and the environment. (2) Methods: In this study, we developed colorimetric loop-mediated isothermal amplification (LAMP) and immunochromatographic test strips (ICTs) for the rapid and visual detection of E. coli O157: H7. This study designed new specific LAMP primers for E. coli O157: H7 virulence island genes. After the LAMP amplification, the double-stranded DNA target sequence labeled with digoxin and fluorescein isothiocyanate (FITC) at both ends was bound to the anti-digoxin antibody on the gold nanoparticles. Subsequently, it was further bound to the anti-FITC antibody at the T line of the ICTs, forming a positive test result. Hydroxynaphthyl blue dye was directly added to the LAMP amplification product. A blue color indicated positive results, while a purple color indicated negative results. (3) Results: Two visualization methods showed high specificity for the target strains. The visualization tests had sensitivities of 5.7 CFU mL(-1), and the detection limit of the Escherichia coli O157: H7 in artificially contaminated milk samples was 5.7 x 10(2) CFU mL(-1), which was consistent with the results of the standard method (LAMP-electrophoresis method) used in commercial inspection. (4) Conclusions: Both methods could be useful in remote and under-resourced areas.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Rapid Detection of Escherichia coli O157:H7 from Chicken Using a Real-time Loop-mediated Amplification Isothermal Assay
    Zhao Y.
    Wang J.
    Lin L.
    Gao Y.
    Wu G.
    Journal of Chinese Institute of Food Science and Technology, 2019, 19 (03) : 281 - 288
  • [2] Rapid and highly sensitive detection of Escherichia coli O157:H7 in food with loop-mediated isothermal amplification coupled to a new bioluminescent assay
    Fei Zhongjie
    Zhou Dongrui
    Dai Wei
    Xiao Pengfeng
    ELECTROPHORESIS, 2020, 41 (20) : 1793 - 1803
  • [3] A highly specific and sensitive loop-mediated isothermal amplification method for the detection of Escherichia coli O157:H7
    Ravan, Hadi
    Amandadi, Mojdeh
    Sanadgol, Nima
    MICROBIAL PATHOGENESIS, 2016, 91 : 161 - 165
  • [4] ESTABLISHMENT AND OPTIMIZATION OF COLORIMETRIC LOOP- MEDIATED ISOTHERMAL AMPLIFICATION FOR VISUAL DETECTION OF ESCHERICHIA COLI O157:H7
    Ye, Congxiu
    Yi, Jinling
    Yin, Songchao
    Li, Meirong
    Li, Yanmei
    ACTA MEDICA MEDITERRANEA, 2016, 32 : 1149 - 1153
  • [5] Rapid and Specific Detection of Escherichia coli O157:H7 in Ground Beef Using Immunomagnetic Separation Combined with Loop-Mediated Isothermal Amplification
    Qin, Yu
    Puthiyakunnon, Santhosh
    Zhang, Yiduo
    Wu, Xianbo
    Boddu, Swapna
    Luo, Binde
    Fan, Hongying
    POLISH JOURNAL OF FOOD AND NUTRITION SCIENCES, 2018, 68 (02) : 115 - 123
  • [6] Loop mediated isothermal amplification as a molecular diagnostic assay: Application and evaluation for detection of Enterohaemorrhagic Escherichia coli (O157:H7)
    Yinur, Degisew
    Moges, Biniam
    Hassen, Aliyi
    Tessema, Tesfaye Sisay
    PRACTICAL LABORATORY MEDICINE, 2023, 37
  • [7] Rapid Detection of Escherichia coli O157:H7 by Loop-Mediated Isothermal Amplification Coupled with a Lateral Flow Assay Targeting the z3276 Genetic Marker
    Xuefeng Xia
    Bicheng Zhang
    Jing Wang
    Bin Li
    Kongwang He
    Xuehan Zhang
    Food Analytical Methods, 2022, 15 : 908 - 916
  • [8] Rapid Detection of Escherichia coli O157:H7 by Loop-Mediated Isothermal Amplification Coupled with a Lateral Flow Assay Targeting the z3276 Genetic Marker
    Xia, Xuefeng
    Zhang, Bicheng
    Wang, Jing
    Li, Bin
    He, Kongwang
    Zhang, Xuehan
    FOOD ANALYTICAL METHODS, 2022, 15 (04) : 908 - 916
  • [9] RAPID AND SIMPLE DETECTION OF SHIGA TOXIN-PRODUCING ESCHERICHIA COLI (STEC) O157:H7 AND STEC NON-O157:H7 SEROTYPES USING COLORIMETRIC LOOP-MEDIATED ISOTHERMAL AMPLIFICATION ASSAY
    Nawattanapaibool, Namfon
    Saiyudthong, Soithong
    Changsen, Chartchai
    Buates, Sureemas
    SOUTHEAST ASIAN JOURNAL OF TROPICAL MEDICINE AND PUBLIC HEALTH, 2021, 52 (02) : 240 - 258
  • [10] A Bipolar Electrode-Electrochemiluminescence Sensor for Sensitive Detection of Escherichia coli O157:H7 Based on Loop-Mediated Isothermal Amplification
    Qi, Yan
    Wang, Fengyang
    Jiang, Yanjun
    Ji, Lei
    Xiong, Xiaohui
    Liu, Yuanjian
    FOOD ANALYTICAL METHODS, 2025,