THE DOSIMETRIC VERIFICATION OF A PENCIL BEAM BASED TREATMENT PLANNING SYSTEM

被引:66
|
作者
KNOOS, T
CEBERG, C
WEBER, L
NILSSON, P
机构
[1] Dept. of Radiat. Phys., Univ. Hospital, Lund
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1994年 / 39卷 / 10期
关键词
D O I
10.1088/0031-9155/39/10/007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new three-dimensional treatment planning system (?Ps) based on convolution/superposition algorithms (TMS-Radix from HELAX AB, Uppsala, Sweden) was recently installed at the University Hospital in Lund. The purpose of the present study was to design a quality assurance and acceptance testing programme to meet the specific characteristics of this convolution model. The model is based on parametrization of a non-measurable quantity-the polyenergetic pencil beam. However, the verification of the treatment planning model is still dependent on numerous comparisons of measured depth-doses and dose profiles. The test programme was divided in two basic parts: (i) model implementation and beam data consistency and (ii) model performance and limitations in special situations. The first part was scheduled for all photon beam qualities available before they could be used for clinical treatment planning. The second part was performed for selected energies only. The results indicate clearly that the model is well suited for clinical three-dimensional dose planning and that the TPS handles data as expected. For example, calculated depth-doses for open and wedge beams at depths larger than the depth of dose maximum and profiles for open beams shows a very good agreement with measurements. However, depth-dose deviations at shallow depths, especially for high energies, were found. Monitor units calculated by the system were accurate for most fields except for very large fields, where deviations of several per cent were found.
引用
收藏
页码:1609 / 1628
页数:20
相关论文
共 50 条
  • [11] Dosimetric evaluation of a treatment planning system using pencil beam convolution algorithm for enhanced dynamic wedges with symmetric and asymmetric fields
    Anjum, M. N.
    Qadir, A.
    Afzal, M.
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2008, 5 (04): : 169 - 174
  • [12] VERIFICATION OF A BEAM MODEL USED IN A TREATMENT PLANNING SYSTEM
    Wieslander, E.
    Knoos, T.
    Engstrom, P.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S253 - S254
  • [13] Dosimetric Verification of MammoSite Irradiation Treatment Planning
    Budde, M.
    Schmolinga, L.
    Ahl-Alhosseini, S.
    Ahl-Alhosseini, A.
    Demirel, C.
    Spaan, B.
    Adamietz, I. A.
    Hermani, H.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 : S98 - S99
  • [14] Dosimetric Verification of stereotactic Radiation Treatment Planning
    Senn, A. M.
    Garbe, S.
    Muedder, T.
    Schoroth, F.
    Roehner, F.
    Koch, D.
    Schmeel, C.
    Wilhelm-Buchstab, T.
    Leitzen, C.
    Heimann, M.
    Tschirner, S.
    Buecheler, B.
    Baumert, B. G.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 : S70 - S70
  • [15] Dosimetric Comparison of Anisotropic Analytical and Pencil Beam Convolution Algorithms in Breast Cancer Radiation Treatment Planning
    Yoo, S.
    O'Daniel, J.
    Horton, J.
    Wu, Q.
    Yin, F.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [16] Interfacing the Pencil Beam Redefinition Algorithm with a Commercial Treatment Planning System
    Carver, R.
    Hogstrom, K.
    Chu, C.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [17] Monte Carlo based verification of a beam model used in a treatment planning system
    Wieslander, E.
    Knoos, T.
    INTERNATIONAL WORKSHOP ON MONTE CARLO TECHNIQUES IN RADIOTHERAPY DELIVERY AND VERIFICATION - THIRD MCGILL INTERNATIONAL WORKSHOP, 2008, 102
  • [18] Validation of a pencil beam model-based treatment planning system for fast neutron therapy
    Bourhis-Martin, E
    Meissner, R
    Rassow, J
    Baumhoer, W
    Schmidt, R
    Sauerwein, W
    MEDICAL PHYSICS, 2003, 30 (01) : 21 - 26
  • [19] Verification of a proton treatment-planning pencil-beam dose algorithm with Monte Carlo
    Titt, U.
    Zheng, Y.
    Zhu, X.
    Mohan, R.
    Newhauser, W.
    MEDICAL PHYSICS, 2006, 33 (06) : 2149 - 2149
  • [20] Dosimetric verification of prowess panter treatment planning system and the evaluation of the clinical acceptance
    Unal Karabey, Aysegul
    Onay, Ozgehan
    Karacam, Songul
    Koca, Sedat
    Atkovar, Gulyuz
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2012, 27 (02): : 76 - 82