THE DOSIMETRIC VERIFICATION OF A PENCIL BEAM BASED TREATMENT PLANNING SYSTEM

被引:66
|
作者
KNOOS, T
CEBERG, C
WEBER, L
NILSSON, P
机构
[1] Dept. of Radiat. Phys., Univ. Hospital, Lund
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1994年 / 39卷 / 10期
关键词
D O I
10.1088/0031-9155/39/10/007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new three-dimensional treatment planning system (?Ps) based on convolution/superposition algorithms (TMS-Radix from HELAX AB, Uppsala, Sweden) was recently installed at the University Hospital in Lund. The purpose of the present study was to design a quality assurance and acceptance testing programme to meet the specific characteristics of this convolution model. The model is based on parametrization of a non-measurable quantity-the polyenergetic pencil beam. However, the verification of the treatment planning model is still dependent on numerous comparisons of measured depth-doses and dose profiles. The test programme was divided in two basic parts: (i) model implementation and beam data consistency and (ii) model performance and limitations in special situations. The first part was scheduled for all photon beam qualities available before they could be used for clinical treatment planning. The second part was performed for selected energies only. The results indicate clearly that the model is well suited for clinical three-dimensional dose planning and that the TPS handles data as expected. For example, calculated depth-doses for open and wedge beams at depths larger than the depth of dose maximum and profiles for open beams shows a very good agreement with measurements. However, depth-dose deviations at shallow depths, especially for high energies, were found. Monitor units calculated by the system were accurate for most fields except for very large fields, where deviations of several per cent were found.
引用
收藏
页码:1609 / 1628
页数:20
相关论文
共 50 条
  • [21] DOSIMETRIC VERIFICATION OF A 3-D ELECTRON PENCIL BEAM DOSE CALCULATION ALGORITHM
    MCSHAN, DL
    FRAASS, BA
    TENHAKEN, RK
    MEDICAL PHYSICS, 1994, 21 (01) : 13 - 23
  • [22] An advantage of Monte Carlo over the pencil beam model based treatment planning system for electron beams
    Cygler, J
    Ding, G
    MEDICAL PHYSICS, 2004, 31 (06) : 1862 - 1862
  • [23] MRI-based treatment planning for radiotherapy: Dosimetric verification for prostate IMRT
    Chen, LL
    Price, RA
    Wang, L
    Li, JS
    Qin, LH
    McNeeley, S
    Ma, CMC
    Freedman, GM
    Pollack, A
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (02): : 636 - 647
  • [24] Development and Validation of a FLASH Pencil Beam Scanning Beam Model for Treatment Planning and Verification in First In-Human Trial
    Zhang, Y.
    Lee, E.
    Xiao, Z.
    Speth, J.
    Folkerts, M.
    Abel, E.
    Breneman, J.
    Mascia, A.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [25] Quantitative dosimetric verification of an IMRT planning and delivery system
    Low, DA
    Mutic, S
    Dempsey, JF
    Gerber, RL
    Bosch, WR
    Perez, CA
    Purdy, JA
    RADIOTHERAPY AND ONCOLOGY, 1998, 49 (03) : 305 - 316
  • [26] A Knowledge-Based Planning Approach for Dosimetric Prediction of Prostate Proton Pencil-Beam Scanning Plans
    Zou, W.
    Teo, B.
    O'Reilly, S.
    Ainsley, C.
    Lin, A.
    Xiao, Y.
    Dong, L.
    Yin, L.
    MEDICAL PHYSICS, 2018, 45 (06) : E658 - E658
  • [27] A Systematic Methodology in Dosimetric Verification of Anisotropic Analytical Algorithm in Eclipse Treatment Planning System
    He, R.
    Yang, C.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [28] Towards helium ion beam treatment planning: a pencil beam algorithm
    Fuchs, H.
    Stroebele, J.
    Schreiner, T.
    Hirtl, A.
    Georg, D.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 (02) : 184 - 184
  • [29] Evaluation of a Pencil Beam Scanning Proton Dose Model for a Commercial Treatment Planning System
    Patel, D.
    Poenisch, F.
    Sahoo, N.
    Zhu, X.
    Gillin, M.
    Janson, M.
    Mohan, R.
    Titt, U.
    MEDICAL PHYSICS, 2018, 45 (06) : E261 - E261
  • [30] Dosimetric verification of the anisotropic analytical algorithm for radiotherapy treatment planning
    Bragg, Christopher M.
    Conway, John
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 (03) : 315 - 323