Preliminary Values of Diagnostic Reference Level for Selected X-Ray Examinations in Indonesia

被引:0
|
作者
Hiswara, E. [1 ]
Prasetio, H. [1 ]
Kartikasari, D. [1 ]
Nuraeni, N. [1 ]
Sandy, K. Y. P. [1 ]
机构
[1] Natl Nucl Energy Agcy, Ctr Radiat Safety Technol & Metrol, Jl Lebak Bulus Raya 49, Jakarta 12070, Indonesia
关键词
Diagnostic radiology; Diagnostic reference levels; Adult patient doses; Entrance surface doses; Children patient doses;
D O I
10.17146/aij.2016.515
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The diagnostic reference levels form an efficient, concise, and powerful standard for optimizing the radiation protection of a patient. With an aim to contribute toward the establishment of the Indonesian National Diagnostic Reference Levels (NDRLs), a nationwide survey of the entrance surface doses received by adult patients during the most typical X-ray examinations has been performed. A number of 44 hospitals in 21 cities located in Java, Bali, Sumatera, Kalimantan, and Sulawesi islands were selected randomly to participate in this survey. Eight most common adult X-ray examinations in 13 projections, as well as four children X-ray examinations in six projections, were included in the list of procedures under consideration. Hospitals of different sizes and levels using different X-ray machines were represented in the survey. Standard thermoluminescence dosemeters were applied to measure entrance surface dose (ESD). A total of 1493 patients, consisting of 1208 adults and 285 children, were included in this study. The data were analyzed statistically and the minimum, median, mean, maximum, first quartile, and third quartile values of ESDs were reported. The ESDs calculated (third quartile) for adults varied from 0.18 mGy (for extremities AP) to 5.84 mGy (for lumbar spine LAT), and for children they varied from 0.16 mGy (for chest AP/PA) to 1.46 mGy (for skull AP/PA). Considering the geographic spread and size of Indonesia, those third quartile values calculated can only be regarded as preliminary DRL values for Indonesia. Compared with data from other countries, the calculated ESDs in this study are in general lower than the ESDs in those countries. (C) 2016 Atom Indonesia. All rights reserved
引用
收藏
页码:99 / 104
页数:6
相关论文
共 50 条
  • [1] Diagnostic reference levels for X-ray examinations
    Veit, R.
    Guggenberger, R.
    Nosske, D.
    Brix, G.
    [J]. RADIOLOGE, 2010, 50 (10): : 907 - +
  • [2] New diagnostic Reference Values for X-Ray
    不详
    [J]. RADIOLOGIE, 2023, 63 (03): : 222 - 222
  • [3] Local diagnostic reference levels in standard X-ray examinations
    Compagnone, G
    Pagan, L
    Bergamini, C
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 113 (01) : 54 - 63
  • [4] Consideration of diagnostic reference levels for pediatric chest X-ray examinations
    Asada, Yasuki
    Ichikawa, Takuma
    [J]. RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2019, 12 (04) : 382 - 387
  • [5] Estimation of adult patient doses for selected X-ray diagnostic examinations
    Ofori, Kofi
    Gordon, Samuel W.
    Akrobortu, Emmanuel
    Ampene, Adriana A.
    Darko, Emmanuel O.
    [J]. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2014, 7 (04) : 459 - 462
  • [6] SUGGESTED DIAGNOSTIC REFERENCE LEVELS FOR PAEDIATRIC X-RAY EXAMINATIONS IN INDIA
    Sonawane, A. U.
    Kumar, J. V. K. Sunil
    Singh, Meghraj
    Pradhan, A. S.
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 147 (03) : 423 - 428
  • [7] Diagnostic reference levels for thorax X-ray examinations of paediatric patients
    Kiljunen, T.
    Jaervinen, H.
    Savolainen, S.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (954): : 452 - 459
  • [8] Consideration of diagnostic reference levels for pediatric chest X-ray examinations
    Yasuki Asada
    Takuma Ichikawa
    [J]. Radiological Physics and Technology, 2019, 12 : 382 - 387
  • [9] Local Diagnostic Reference Levels for X-Ray Examinations in an Australian Tertiary Hospital
    Ng, Curtise K. C.
    Sun, Zhonghua
    Parry, Helen
    Burrage, John
    [J]. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2014, 4 (02) : 297 - 302
  • [10] Local Diagnostic Reference Levels (LDRLs) for routine X-ray examinations in Morocco
    Talbi, M.
    Tahiri, Z.
    Eddaoui, K.
    El Mansouri, M.
    Nhila, O.
    Benmessaoud, M.
    Ait Ouaggou, I.
    Chakir, E.
    Sebihi, R.
    Khalis, M.