Preliminary Values of Diagnostic Reference Level for Selected X-Ray Examinations in Indonesia

被引:0
|
作者
Hiswara, E. [1 ]
Prasetio, H. [1 ]
Kartikasari, D. [1 ]
Nuraeni, N. [1 ]
Sandy, K. Y. P. [1 ]
机构
[1] Natl Nucl Energy Agcy, Ctr Radiat Safety Technol & Metrol, Jl Lebak Bulus Raya 49, Jakarta 12070, Indonesia
关键词
Diagnostic radiology; Diagnostic reference levels; Adult patient doses; Entrance surface doses; Children patient doses;
D O I
10.17146/aij.2016.515
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The diagnostic reference levels form an efficient, concise, and powerful standard for optimizing the radiation protection of a patient. With an aim to contribute toward the establishment of the Indonesian National Diagnostic Reference Levels (NDRLs), a nationwide survey of the entrance surface doses received by adult patients during the most typical X-ray examinations has been performed. A number of 44 hospitals in 21 cities located in Java, Bali, Sumatera, Kalimantan, and Sulawesi islands were selected randomly to participate in this survey. Eight most common adult X-ray examinations in 13 projections, as well as four children X-ray examinations in six projections, were included in the list of procedures under consideration. Hospitals of different sizes and levels using different X-ray machines were represented in the survey. Standard thermoluminescence dosemeters were applied to measure entrance surface dose (ESD). A total of 1493 patients, consisting of 1208 adults and 285 children, were included in this study. The data were analyzed statistically and the minimum, median, mean, maximum, first quartile, and third quartile values of ESDs were reported. The ESDs calculated (third quartile) for adults varied from 0.18 mGy (for extremities AP) to 5.84 mGy (for lumbar spine LAT), and for children they varied from 0.16 mGy (for chest AP/PA) to 1.46 mGy (for skull AP/PA). Considering the geographic spread and size of Indonesia, those third quartile values calculated can only be regarded as preliminary DRL values for Indonesia. Compared with data from other countries, the calculated ESDs in this study are in general lower than the ESDs in those countries. (C) 2016 Atom Indonesia. All rights reserved
引用
下载
收藏
页码:99 / 104
页数:6
相关论文
共 50 条
  • [11] DIAGNOSTIC X-RAY EXAMINATIONS - NEED TO BE CONCERNED
    BONELLI, J
    MATERIALS EVALUATION, 1977, 35 (09) : 51 - 53
  • [12] Entrance surface doses to patients undergoing selected diagnostic X-ray examinations in Sudan
    Suliman, I. I.
    Abbas, N.
    Habbani, F. I.
    RADIATION PROTECTION DOSIMETRY, 2007, 123 (02) : 209 - 214
  • [13] Diagnostic reference levels (DRLs) for routine X-ray examinations in Lorestan province, Iran
    Gholami, M.
    Maziar, A.
    Khosravi, H. R.
    Ebrahimzadeh, F.
    Mayahi, S.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2015, 13 (01): : 85 - 90
  • [14] Local diagnostic reference levels for some common diagnostic X-ray examinations in Tehran county of Iran
    Toosi, Mohammad Taghi Bahreyni
    Asadinezhad, Mohsen
    RADIATION PROTECTION DOSIMETRY, 2007, 124 (02) : 137 - 144
  • [15] PATIENT DOSES IN COMMON DIAGNOSTIC X-RAY EXAMINATIONS
    Metaxas, Vasileios, I
    Messaris, Gerasimos A.
    Lekatou, Aristea N.
    Petsas, Theodore G.
    Panayiotakis, George S.
    RADIATION PROTECTION DOSIMETRY, 2019, 184 (01) : 12 - 27
  • [16] Reference dose levels for patients undergoing common diagnostic X-ray examinations in Irish hospitals
    Johnston, DA
    Brennan, PC
    BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (868): : 396 - 402
  • [17] Variabilities in X-ray diagnostic reference levels
    Vanaudenhove, Thibault
    Van Muylem, Alain
    Howarth, Nigel
    Gevenois, Pierre Alain
    Tack, Denis
    EUROPEAN RADIOLOGY, 2020, 30 (08) : 4641 - 4647
  • [18] Variabilities in X-ray diagnostic reference levels
    Thibault Vanaudenhove
    Alain Van Muylem
    Nigel Howarth
    Pierre Alain Gevenois
    Denis Tack
    European Radiology, 2020, 30 : 4641 - 4647
  • [19] Doses to patients in some routine diagnostic X-ray examinations in Iran: proposed the first Iranian diagnostic reference levels
    Asadinezhad, Mohsen
    Bahreyni Toossi, Mohammad Taghi
    RADIATION PROTECTION DOSIMETRY, 2008, 132 (04) : 409 - 414
  • [20] ESTIMATION OF ADULT PATIENT DOSES FOR CHEST X-RAY EXAMINATIONS AND COMPARISON WITH DIAGNOSTIC REFERENCE LEVELS (DRLS)
    Mor, H. Bas
    Altinsoy, N.
    Soyler, I.
    RADIATION PROTECTION DOSIMETRY, 2018, 182 (03) : 377 - 385