Preliminary Values of Diagnostic Reference Level for Selected X-Ray Examinations in Indonesia

被引:0
|
作者
Hiswara, E. [1 ]
Prasetio, H. [1 ]
Kartikasari, D. [1 ]
Nuraeni, N. [1 ]
Sandy, K. Y. P. [1 ]
机构
[1] Natl Nucl Energy Agcy, Ctr Radiat Safety Technol & Metrol, Jl Lebak Bulus Raya 49, Jakarta 12070, Indonesia
关键词
Diagnostic radiology; Diagnostic reference levels; Adult patient doses; Entrance surface doses; Children patient doses;
D O I
10.17146/aij.2016.515
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The diagnostic reference levels form an efficient, concise, and powerful standard for optimizing the radiation protection of a patient. With an aim to contribute toward the establishment of the Indonesian National Diagnostic Reference Levels (NDRLs), a nationwide survey of the entrance surface doses received by adult patients during the most typical X-ray examinations has been performed. A number of 44 hospitals in 21 cities located in Java, Bali, Sumatera, Kalimantan, and Sulawesi islands were selected randomly to participate in this survey. Eight most common adult X-ray examinations in 13 projections, as well as four children X-ray examinations in six projections, were included in the list of procedures under consideration. Hospitals of different sizes and levels using different X-ray machines were represented in the survey. Standard thermoluminescence dosemeters were applied to measure entrance surface dose (ESD). A total of 1493 patients, consisting of 1208 adults and 285 children, were included in this study. The data were analyzed statistically and the minimum, median, mean, maximum, first quartile, and third quartile values of ESDs were reported. The ESDs calculated (third quartile) for adults varied from 0.18 mGy (for extremities AP) to 5.84 mGy (for lumbar spine LAT), and for children they varied from 0.16 mGy (for chest AP/PA) to 1.46 mGy (for skull AP/PA). Considering the geographic spread and size of Indonesia, those third quartile values calculated can only be regarded as preliminary DRL values for Indonesia. Compared with data from other countries, the calculated ESDs in this study are in general lower than the ESDs in those countries. (C) 2016 Atom Indonesia. All rights reserved
引用
收藏
页码:99 / 104
页数:6
相关论文
共 50 条
  • [42] Metacarpal index by digital X-ray radiogrammetry - Normative reference values and comparison with dual X-ray absorptionmetry
    Hyldstrup, L
    Nielsen, SP
    JOURNAL OF CLINICAL DENSITOMETRY, 2001, 4 (04) : 299 - 306
  • [43] PREVENTIVE X-RAY MEASUREMENTS AND THEIR INTERPRETATION IN X-RAY DIAGNOSTIC INCLUSIVE OF PEDIATRIC X-RAY DIAGNOSTIC
    TASCHNER, P
    MENZEL, B
    KONIG, W
    FRIEDRIC.H
    DEUTSCHE GESUNDHEITSWESEN-ZEITSCHRIFT FUR KLINISCHE MEDIZIN, 1974, 29 (31): : 1449 - 1452
  • [44] Estimation of patients' organ doses and conceptus doses from selected X-ray examinations in two Nigeria X-ray centres
    Ogundare, F. O.
    Olarinoye, I. O.
    Obed, R. I.
    RADIATION PROTECTION DOSIMETRY, 2008, 132 (04) : 395 - 402
  • [45] Estimation of adult patient doses for common diagnostic X-ray examinations in Wad-madani, Sudan: derivation of local diagnostic reference levels
    I. I. Suliman
    T. S. Mohammedzein
    Australasian Physical & Engineering Sciences in Medicine, 2014, 37 : 425 - 429
  • [46] Estimation of adult patient doses for common diagnostic X-ray examinations in Wad-madani, Sudan: derivation of local diagnostic reference levels
    Suliman, I. I.
    Mohammedzein, T. S.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2014, 37 (02) : 425 - 429
  • [47] Evaluation of the Entrance Surface Doses (ESD) for common diagnostic X-ray examinations
    Alomairy, Nada
    Hadi, Dareen
    Al-Zaid, Amna
    Fasikh, Rawan
    Arif, Raneem
    Al-Hazmi, Rawan
    Kharizy, Ali
    Alyami, Ali
    Hummdy, Ahmed
    Shubayr, Nasser
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2023, 16 (04)
  • [48] A phantom study showing the importance of compression in conventional diagnostic X-ray examinations
    Olsson, M. -L.
    Tingberg, A.
    Mattsson, S.
    RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) : 78 - 80
  • [49] INTRAORAL DENTAL X-RAY RADIOGRAPHY IN BOSNIA AND HERZEGOVINA: STUDY FOR REVISING DIAGNOSTIC REFERENCE LEVEL VALUE
    Praskalo, Jovica
    Beganovic, Adnan
    Milanovic, Jovana
    Stankovic, Koviljka
    RADIATION PROTECTION DOSIMETRY, 2020, 190 (01) : 90 - 99
  • [50] Concerning the level values of x-ray spectrums in chemical elements
    Walter, B
    ZEITSCHRIFT FUR PHYSIK, 1924, 30 : 357 - 371