A Method for In-Situ Calibration of Semiconductor Detectors

被引:0
|
作者
Wernisch, Johann [1 ]
Schoenthaler, Angela [1 ]
August, Hans-Juergen [1 ]
机构
[1] Tech Univ Wien, Inst Angew & Tech Phys, A-1040 Vienna, Austria
关键词
Si(Li)-detector; calibration;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A Si(Li)-detector has been calibrated for low and medium X-ray energies (E-nu less than or similar to 10 keV) using the method of variation of the X-ray incidence angle, of which the theory is briefly outlined. If the thickness of the Au-contact layer is assumed to be known, the thicknesses of the Si-dead layer and of the Be-window have been determined from a least-squares fit to the experimental data, which were obtained at different X-ray energies. A mathematical simulation of the Bremsstrahlung spectrum, recorded by the detector, confirmed that the obtained results can be regarded as realistic and reliable.
引用
收藏
页码:147 / 152
页数:6
相关论文
共 50 条
  • [21] In-situ Calibration Method of FBG Strain Sensor under Dynamic Excitation
    Lu Ye
    Gong Huaping
    Cai Jingyi
    Fan Qiming
    Zhao Chunliu
    ACTA PHOTONICA SINICA, 2023, 52 (01)
  • [22] Adaptive filtering based sodium flow measurement method for in-situ calibration
    Wu, Wen-Kai
    Xu, Ke-Jun
    Yu, Xin-Long
    Yan, Xiao-Xue
    Huang, Ya
    Xu, Wei
    ANNALS OF NUCLEAR ENERGY, 2021, 150
  • [23] ANALYTICAL CALIBRATION METHOD FOR IN-SITU NEUTRON-CAPTURE GAMMA SONDES
    SOHRABPOUR, M
    BULL, SR
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1973, 17 (NOV): : 121 - 122
  • [24] DETERMINISTIC ANALYTICAL METHOD FOR THE CALIBRATION OF SEMICONDUCTOR-DETECTORS IN GAMMA-RAY SPECTROMETRY
    GENICOT, JL
    HARDEMAN, F
    WAETERMANS, F
    RADIATION PROTECTION DOSIMETRY, 1995, 61 (1-3) : 141 - 144
  • [25] A calibration method for phoswich detectors
    Gawlikowicz, W
    Toke, J
    Schröder, WU
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 491 (1-2): : 181 - 193
  • [26] In-situ calibration of the CMS electromagnetic calorimeter
    Futyan, DI
    PARTICLES AND THE UNIVERSE, 2004, : 211 - 217
  • [27] Robust, "blind", in-situ calibration of SODARs
    Bradley, Stuart
    14TH INTERNATIONAL SYMPOSIUM FOR THE ADVANCEMENT OF BOUNDARY LAYER REMOTE SENSING, 2008, 1 : U74 - U79
  • [28] In-Situ Probes for Antenna Array Calibration
    Stark, A.
    Johannsen, U.
    Jacob, A. F.
    40TH EUROPEAN MICROWAVE CONFERENCE, 2010, : 465 - 468
  • [29] In-situ calibration of the implantable force transducer
    Herzog, W
    Hasler, EM
    Leonard, TR
    JOURNAL OF BIOMECHANICS, 1996, 29 (12) : 1649 - 1652
  • [30] Calibration factors for in-situ radiation surveys
    Bramlitt, ET
    Woods, JA
    PROCEEDINGS OF THE 1996 TOPICAL MEETING RADIATION PROTECTION & SHIELDING, VOLS 1 AND 2, 1996, 1-2 : 163 - 170