A Method for In-Situ Calibration of Semiconductor Detectors

被引:0
|
作者
Wernisch, Johann [1 ]
Schoenthaler, Angela [1 ]
August, Hans-Juergen [1 ]
机构
[1] Tech Univ Wien, Inst Angew & Tech Phys, A-1040 Vienna, Austria
关键词
Si(Li)-detector; calibration;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A Si(Li)-detector has been calibrated for low and medium X-ray energies (E-nu less than or similar to 10 keV) using the method of variation of the X-ray incidence angle, of which the theory is briefly outlined. If the thickness of the Au-contact layer is assumed to be known, the thicknesses of the Si-dead layer and of the Be-window have been determined from a least-squares fit to the experimental data, which were obtained at different X-ray energies. A mathematical simulation of the Bremsstrahlung spectrum, recorded by the detector, confirmed that the obtained results can be regarded as realistic and reliable.
引用
收藏
页码:147 / 152
页数:6
相关论文
共 50 条
  • [41] A method for continuous in-situ pathlength calibration of integrating sphere based gas cells
    Bergin, S.
    Hodgkinson, J.
    Francis, D.
    Tatam, R. P.
    ADVANCED ENVIRONMENTAL, CHEMICAL, AND BIOLOGICAL SENSING TECHNOLOGIES XII, 2015, 9486
  • [42] Investigation into the properties of CdTe detectors for in-situ measurements
    Kastlander, J.
    Bargholtz, Chr.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 596 (03): : 409 - 416
  • [43] Easy calibration method of vision system for in-situ measurement of strain of thin films
    Park, Jun-Hyub
    Kang, Dong-Joong
    Shin, Myung-Soo
    Lim, Sung-Jo
    Yu, Son-Cheol
    Lee, Kwang-Soo
    Ha, Jong-Eun
    Choa, Sung-Hoon
    TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2009, 19 : S243 - S249
  • [44] Extended virtual in-situ calibration method in building systems using Bayesian inference
    Yoon, Sungmin
    Yu, Yuebin
    AUTOMATION IN CONSTRUCTION, 2017, 73 : 20 - 30
  • [45] In-situ Simple Rapid Calibration Method for the EC-5 Moisture Sensor
    Mochizuki, Hidetoshi
    Sakaguchi, Iwao
    JARQ-JAPAN AGRICULTURAL RESEARCH QUARTERLY, 2023, 57 (02): : 131 - 137
  • [46] Easy calibration method of vision system for in-situ measurement of strain of thin films
    Jun-Hyub PARK
    Dong-Joong KANG
    Myung-Soo SHIN
    Sung-Jo LIM
    Son-Cheol YU
    Kwang-Soo LEE
    Jong-Eun HA
    Sung-Hoon CHOA
    Transactions of Nonferrous Metals Society of China, 2009, 19(S1) (S1) : 243 - 249
  • [47] In-situ nonlinear calibration of a RF signal chain
    Rakuljic, Nevena
    Speir, Carroll
    Otte, Eric
    Bray, Jeff
    Petersen, Corey
    Manganaro, Gabriele
    2018 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2018,
  • [48] In-situ sensor virtualization and calibration in building systems
    Koo, Jabeom
    Yoon, Sungmin
    APPLIED ENERGY, 2022, 325
  • [49] IN-SITU CALIBRATION TECHNIQUE FOR UV SPECTRAL RADIOMETERS
    WILSON, SR
    FORGAN, BW
    APPLIED OPTICS, 1995, 34 (24): : 5475 - 5484
  • [50] In-situ calibration of acoustic measurements of suspended sediment
    Guo Jijie
    Ren inifa
    and Li Yunwu( Institute of Ocean Technology
    Acta Oceanologica Sinica, 1999, (04) : 3 - 5