A calibration method for phoswich detectors

被引:7
|
作者
Gawlikowicz, W [1 ]
Toke, J [1 ]
Schröder, WU [1 ]
机构
[1] Univ Rochester, Dept Chem, Rochester, NY 14627 USA
关键词
phoswich detectors; energy calibration; particle identification;
D O I
10.1016/S0168-9002(02)01230-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new method of particle identification and energy calibration is proposed for phoswich detectors consisting of a fast plastic scintillator optically coupled to a CsI(Tl) crystal. In this method, functional relationships between integrated yields of three properly selected portions of the observed composite light output signal are parameterized in terms of three physical components (overlapping in time) of this signal. Then, a complete set of calibration constants is derived, linking these integrated partial yields to particle atomic numbers (Z) and energies (E). The calibration is based on the correlations between partial yields observed in actual data from the physics or "production" runs, and energy deposits calculated for detector elements. The method is found suitable for a wide range of incident particle species and energies, largely eliminating the need for costly and time-consuming conventional calibration experiments with a variety of beams, targets, and bombarding energies. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:181 / 193
页数:13
相关论文
共 50 条
  • [1] CALIBRATION OF PHOSWICH DETECTORS
    LEEGTE, HKW
    KOLDENHOF, EE
    BOONSTRA, AL
    WILSCHUT, HW
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 313 (1-2): : 26 - 30
  • [2] Calibration of plastic phoswich detectors for charged particle detection
    Fox, D
    Bowman, DR
    Ball, GC
    GalindoUribarri, A
    Hagberg, E
    Horn, D
    Beaulieu, L
    Larochelle, Y
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 374 (01): : 63 - 69
  • [3] The calibration characteristics of the gamma-channel of phoswich detectors of different models
    O. M. Anshakov
    N. V. Bakovets
    A. I. Zhukovskii
    S. A. Soroka
    E. M. Khadzhinov
    V. A. Chudakov
    [J]. Measurement Techniques, 2006, 49 : 1145 - 1150
  • [4] Calibration Process for Improving Crystal Identification Rate in the LabPET™ Phoswich Detectors
    Lemieux, Francois
    Viscogliosi, Nicolas
    Tetrault, Marc-Andre
    Lecomte, Roger
    Fontaine, Rejean
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1081 - 1086
  • [5] CALIBRATION OF PHOSWICH DETECTORS FOR ASSESSMENT OF PLUTONIUM IN LUNGS - THE METHODS OF 4 LABORATORIES COMPARED
    CAMPBELL, GW
    ANDERSON, AL
    FRY, FA
    NEWTON, D
    RAMSDEN, D
    [J]. HEALTH PHYSICS, 1981, 40 (03): : 405 - 409
  • [6] Phoswich Detectors in Sensing Applications
    Min, Sujung
    Seo, Bumkyung
    Roh, Changhyun
    Hong, Sangbum
    Cheong, JaeHak
    [J]. SENSORS, 2021, 21 (12)
  • [7] Ionizing radiation measurements the calibration characteristics of the gamma-channel of phoswich detectors of different models
    Anshakov, O. M.
    Bakovets, N. V.
    Zhukovskii, A. I.
    Soroka, S. A.
    Khadzhinov, E. M.
    Chudakov, V. A.
    [J]. MEASUREMENT TECHNIQUES, 2006, 49 (11) : 1145 - 1150
  • [8] Photoluminescence Characterization of Scintillators for Phoswich Detectors
    Zhuravleva, Mariya
    Melcher, Charles L.
    Eriksson, Lars
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2407 - 2410
  • [9] PULSE SHAPE ANALYZER FOR PHOSWICH DETECTORS
    SHOFFNER, BM
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1972, NS19 (01) : 502 - &
  • [10] POSITION-SENSITIVE PHOSWICH DETECTORS
    CHAN, Y
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 : 54 - NUCL