A COMPARISON OF THE DIMENSIONS OF A TRUNCATED CONE MEASURED WITH VARIOUS TECHNIQUES - THE CONE MEASUREMENT PROJECT

被引:0
|
作者
MACKAY, ME [1 ]
DICK, GK [1 ]
机构
[1] UNIV QUEENSLAND,DEPT ENGN MECH,METROL LAB,BRISBANE,QLD 4072,AUSTRALIA
关键词
D O I
10.1122/1.550650
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
A mock truncated cone was manufactured and sent to 12 participants throughout the world for measurement of appropriate dimensions. The results indicated that the error in measuring the cone diameter was trivial while the cone angle and truncation height had errors of ±4.79% and ± 12.4%, respectively, based on the standard deviation of all measurements. Two groups had reported values of the cone angle which were statistically high and when these values were ignored the error in the cone angle was reduced to ± 1.38%. These errors are lower than previously quoted accuracies in the literature. Since the measurement techniques used for the five most accurate measurements are not new, it is concluded that care of the person performing the measurement is critical. The effect of errors on the geometric variables’ values on the shear rate, shear stress, and first normal stress difference are discussed. © 1995, The Society of Rheology. All rights reserved.
引用
收藏
页码:673 / 677
页数:5
相关论文
共 50 条
  • [31] ATTRIBUTIONAL MEASUREMENT TECHNIQUES - CLASSIFICATION AND COMPARISON OF APPROACHES FOR MEASURING CAUSAL DIMENSIONS
    BENSON, MJ
    JOURNAL OF SOCIAL PSYCHOLOGY, 1989, 129 (03): : 307 - 323
  • [32] Comparison of cone and OSU calorimetric techniques to assess the flammability behaviour of fabrics used for aircraft interiors
    Kandola, B. K.
    Horrocks, A. R.
    Padmore, K.
    Dalton, Joyce
    Owen, Tim
    FIRE AND MATERIALS, 2006, 30 (04) : 241 - 255
  • [33] The S-cone electroretinogram: a comparison of techniques, normative data and age-related variation
    Chiti, Z
    North, RV
    Mortlock, KE
    Drasdo, N
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2003, 23 (04) : 370 - 376
  • [34] Image reconstruction with laterally truncated projections in helical cone-beam CT: Linear prediction based projection completion techniques
    Anoop, K. P.
    Rajgopal, Kasi
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2009, 33 (04) : 283 - 294
  • [35] Carotid artery stenosis measurement: Comparison of cone-beam CT and digital subtraction angiography
    Hyde, D
    Fox, A
    Gulka, I
    Kalapos, P
    Lee, D
    Pelz, D
    MEDICAL PHYSICS, 2003, 30 (07) : 1950 - 1950
  • [36] Photolysis frequency measurement techniques: results of a comparison within the ACCENT project
    Bohn, B.
    Corlett, G. K.
    Gillmann, M.
    Sanghavi, S.
    Stange, G.
    Tensing, E.
    Vrekoussis, M.
    Bloss, W. J.
    Clapp, L. J.
    Kortner, M.
    Dorn, H. -P.
    Monks, P. S.
    Platt, U.
    Plass-Dulmer, C.
    Mihalopoulos, N.
    Heard, D. E.
    Clemitshaw, K. C.
    Meixner, F. X.
    Prevot, A. S. H.
    Schmitt, R.
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2008, 8 (17) : 5373 - 5391
  • [37] Soft Tissue Cone-Beam Computed Tomography: A Novel Method for the Measurement of Gingival Tissue and the Dimensions of the Dentogingival Unit
    Januario, Alessandro Lourenco
    Barriviera, Mauricio
    Duarte, Wagner Rodrigues
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2008, 20 (06) : 366 - 373
  • [38] HU and Dosimetric Comparison of Six Cone-Beam CT Acquisition Techniques for Radiation Therapy Planning
    Leeper, S.
    Yoo, S.
    Yin, F. F.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [39] Comparison of Clinical, Periapical Radiograph, and Cone-Beam Volume Tomography Measurement Techniques for Assessing Bone Level Changes Following Regenerative Periodontal Therapy
    Grimard, Brently A.
    Hoidal, Matt J.
    Mills, Michael P.
    Mellonig, James T.
    Nummikoski, Pirkka V.
    Mealey, Brian L.
    JOURNAL OF PERIODONTOLOGY, 2009, 80 (01) : 48 - 55
  • [40] ON THE MEASUREMENT OF NORMAL STRESS DIFFERENCES IN STEADY SHEAR-FLOW .4. A NEW TRUNCATED-CONE AND PLATE (TCP) APPARATUS
    LODGE, AS
    HOU, TH
    RHEOLOGICA ACTA, 1981, 20 (03) : 247 - 260