A COMPARISON OF THE DIMENSIONS OF A TRUNCATED CONE MEASURED WITH VARIOUS TECHNIQUES - THE CONE MEASUREMENT PROJECT

被引:0
|
作者
MACKAY, ME [1 ]
DICK, GK [1 ]
机构
[1] UNIV QUEENSLAND,DEPT ENGN MECH,METROL LAB,BRISBANE,QLD 4072,AUSTRALIA
关键词
D O I
10.1122/1.550650
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
A mock truncated cone was manufactured and sent to 12 participants throughout the world for measurement of appropriate dimensions. The results indicated that the error in measuring the cone diameter was trivial while the cone angle and truncation height had errors of ±4.79% and ± 12.4%, respectively, based on the standard deviation of all measurements. Two groups had reported values of the cone angle which were statistically high and when these values were ignored the error in the cone angle was reduced to ± 1.38%. These errors are lower than previously quoted accuracies in the literature. Since the measurement techniques used for the five most accurate measurements are not new, it is concluded that care of the person performing the measurement is critical. The effect of errors on the geometric variables’ values on the shear rate, shear stress, and first normal stress difference are discussed. © 1995, The Society of Rheology. All rights reserved.
引用
收藏
页码:673 / 677
页数:5
相关论文
共 50 条
  • [41] A Comparison of Cone-Beam Computed Tomography and Direct Measurement in the Examination of the Mandibular Canal and Adjacent Structures
    Kim, Thomas S.
    Caruso, Joseph M.
    Christensen, Heidi
    Torabinejad, Mahmoud
    JOURNAL OF ENDODONTICS, 2010, 36 (07) : 1191 - 1194
  • [42] Comparison of intraoral digital radiography and cone-beam computed tomography in the measurement of periodontal bone defects
    Abdinian, Mehrdad
    Yaghini, Jaber
    Jazi, Leila
    DENTAL AND MEDICAL PROBLEMS, 2020, 57 (03) : 269 - 273
  • [43] Comparison between Digital Casts and Cone Beam Computed Tomography for Measuring Maxillary Transverse Dimensions in Patients with Impacted Canines
    Martinez Madero, Elena
    Garcia Montarelo, Jaime
    Aguayo, Grace Stefany
    Martin, Conchita
    CHILDREN-BASEL, 2022, 9 (02):
  • [44] Comparison of Lung Tumor Volume Reduction Rates Measured by Cone Beam Computed Tomography Across Different Fractionation Schedules
    Choi, S.
    Wahl, M.
    Braunstein, S. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E584 - E585
  • [45] Comparison of Intracranial Stereotactic Radiotherapy (SRS/SRT) Plan Quality Using CyberKnife, Eclipse MLC and Cone Techniques
    Zhang, X.
    Jang, S.
    Lee, S.
    Hirsch, A.
    Mak, K.
    Dyer, M.
    Truong, M.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [46] Performance of cone beam computed tomography in comparison to conventional imaging techniques for the detection of bone invasion in oral cancer
    Linz, C.
    Mueller-Richter, U. D. A.
    Buck, A. K.
    Mottok, A.
    Ritter, C.
    Schneider, P.
    Metzen, D.
    Heuschmann, P.
    Malzahn, U.
    Kuebler, A. C.
    Herrmann, K.
    Bluemel, C.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 44 (01) : 8 - 15
  • [47] The Dimensions of the Mandibular Incisive Canal and Its Spatial Relationship to Various Anatomical Landmarks of the Mandible: A Study Using Cone Beam Computed Tomography
    Apostolakis, Dimitrios
    Brown, Jackie E.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) : 117 - 124
  • [48] Comparison of Craniofacial Anthropometric Measurement Accuracy of Manual Technique vs. Cone-Beam CT Scanning
    Misailoaie, Alexandru
    Taraboanta, Ionut
    Stan, Cristinel Ionel
    Budacu, Cristian Constantin
    Misailoaie, Denisa-Mihaela
    Sava, Anca
    DIAGNOSTICS, 2024, 14 (22)
  • [49] Comparison of in vivo 3D cone-beam computed tomography tooth volume measurement protocols
    Forst D.
    Nijjar S.
    Flores-Mir C.
    Carey J.
    Secanell M.
    Lagravere M.
    Progress in Orthodontics, 15 (1) : 69
  • [50] Comparison of set up errors measured in 2D and 3D using EPI and cone beam CT
    Marchant, T
    Amer, A
    Moore, C
    Stratford, J
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S128 - S128