A COMPARISON OF THE DIMENSIONS OF A TRUNCATED CONE MEASURED WITH VARIOUS TECHNIQUES - THE CONE MEASUREMENT PROJECT

被引:0
|
作者
MACKAY, ME [1 ]
DICK, GK [1 ]
机构
[1] UNIV QUEENSLAND,DEPT ENGN MECH,METROL LAB,BRISBANE,QLD 4072,AUSTRALIA
关键词
D O I
10.1122/1.550650
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
A mock truncated cone was manufactured and sent to 12 participants throughout the world for measurement of appropriate dimensions. The results indicated that the error in measuring the cone diameter was trivial while the cone angle and truncation height had errors of ±4.79% and ± 12.4%, respectively, based on the standard deviation of all measurements. Two groups had reported values of the cone angle which were statistically high and when these values were ignored the error in the cone angle was reduced to ± 1.38%. These errors are lower than previously quoted accuracies in the literature. Since the measurement techniques used for the five most accurate measurements are not new, it is concluded that care of the person performing the measurement is critical. The effect of errors on the geometric variables’ values on the shear rate, shear stress, and first normal stress difference are discussed. © 1995, The Society of Rheology. All rights reserved.
引用
收藏
页码:673 / 677
页数:5
相关论文
共 50 条
  • [21] Experimental Comparison of Different Noise Reduction Techniques on Cone Beam Computed Tomography Images
    Yilmaz, Ercument
    Kayikcioglu, Temel
    Kayipmaz, Saadettin
    2014 22ND SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2014, : 2086 - 2089
  • [23] Comparison between the adherence of a rigid axisymmetrical cone and a truncated one, in adhesive contact on an elastic half-space
    Barquins, M
    JOURNAL OF ADHESION, 2003, 79 (10): : 915 - 936
  • [24] Comparison of Kemi-I and Confederation Bridge cone ice load measurement results
    Brown, Thomas G.
    Maattanen, Mauri
    COLD REGIONS SCIENCE AND TECHNOLOGY, 2009, 55 (01) : 3 - 13
  • [25] Dimensions of central incisors, canines, and first molars in subjects with Down syndrome measured on cone-beam computed tomographs
    Teresa Abeleira, Maria
    Outumuro, Mercedes
    Ramos, Isabel
    Limeres, Jacobo
    Diniz, Marcio
    Diz, Pedro
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 146 (06) : 765 - 775
  • [26] Experimental Comparison of Six Commercial Dosimetry Diodes for Measurement of Stereotactic Radiosurgery Cone Factors
    Sherouse, G.
    Dieterich, S.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [27] Experimental comparison of seven commercial dosimetry diodes for measurement of stereotactic radiosurgery cone factors
    Dieterich, Sonja
    Sherouse, George W.
    MEDICAL PHYSICS, 2011, 38 (07) : 4166 - 4173
  • [28] Generation and evaluation of synthetic cone penetration test (CPT) data using various spatial interpolation techniques
    Rahman, Md Habibur
    Abu-Farsakh, Murad Y.
    Jafari, Navid
    CANADIAN GEOTECHNICAL JOURNAL, 2021, 58 (02) : 224 - 237
  • [29] Comparison of Nasal Dimensions According to the Facial and Nasal Indices Using Cone-Beam Computed Tomography
    Lee, Jeong-Hyun
    Kim, Hey-Suk
    Park, Jong-Tae
    JOURNAL OF PERSONALIZED MEDICINE, 2024, 14 (04):
  • [30] THIN-FILM THICKNESS MEASUREMENT - A COMPARISON OF VARIOUS TECHNIQUES
    PIEGARI, A
    MASETTI, E
    THIN SOLID FILMS, 1985, 124 (3-4) : 249 - 257