Effect of Different Breast Densities and Average Glandular Dose on Contrast to Noise Ratios in Full-Field Digital Mammography: Simulation and Phantom Study

被引:4
|
作者
Nakamura, Noriko [1 ,2 ]
Okafuji, Yuka [1 ]
Adachi, Saori [1 ]
Takahashi, Kana [3 ]
Nakakuma, Takashi [3 ]
Ueno, Sohichirou [3 ]
机构
[1] Ageo Cent Gen Hosp, Dept Radiol, Ageo City, Saitama 3628588, Japan
[2] Suzuka Univ Med Sci, Grad Sch Hlth Sci, Suzuka, Mie 5100293, Japan
[3] Ageo Cent Gen Hosp, Dept Breast Surg, Ageo City, Saitama 3628588, Japan
关键词
D O I
10.1155/2018/6192594
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We aimed to investigate the effects of mammary gland density and average glandular dose (AGD) on contrast-to-noise ratio (CNR) of breast-equivalent phantoms with different mammary gland/fat tissue ratios. Full-field digital-mammography breast X-rays were performed on breast-equivalent phantoms with three different mammary gland/fat tissue ratios (Phantom A [30/70], Phantom B [50/50], and Phantom C [70/30]) and seven thicknesses ranging from 10 mm to 70 mm. The prediction formula for the CNR was calculated by multivariate analysis and the effects of the various parameters on CNR were evaluated using a multiple regression analysis model. Higher CNR values were obtained with lower mammary gland/fat tissue ratios and lower phantom thicknesses. Variation in CNR among the three breast models was low (coefficient of variation, 3.4-8.7%) at lower phantom thicknesses (10-30 mm) and high (coefficient of variation, 10.5-16.8%) at higher phantom thickness (50-70 mm). CNR showed a strong negative correlation (r = -0.8989) with AGD across all three mammary gland ratios. A predictive formula for CNR using AGD and mammary gland density was developed. CNR can be predicted with high precision using AGD and mammary gland density. The predicted CNR could be used to measure the diagnostic reliability of mammography in breast cancer.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Dose Reduction in Automatic Optimization Parameter of Full Field Digital Mammography: Breast Phantom Study
    Ko, Myung-Su
    Kim, Hak Hee
    Cha, Joo Hee
    Shin, Hee Jung
    Kim, Jeoung Hyun
    Kim, Min Jeong
    [J]. JOURNAL OF BREAST CANCER, 2013, 16 (01) : 90 - 96
  • [22] Automatic exposure control in digital mammography:: Contrast-to-noise ratio versus average glandular dose
    Gennaro, Gisella
    Golinelli, Paola
    Bellan, Elena
    Colombo, Paola
    D'Ercole, Loredana
    Di Nallo, Anna
    Gallo, Lara
    Giordano, Carlo
    Meliado, Gabriele
    Morri, Barbara
    Nassivera, Elvina
    Oberhofer, Nadia
    Origgi, Daniela
    Paolucci, Massimiliano
    Paruccini, Nicoletta
    Piergentili, Michela
    Rizzi, Elisa
    Rossi, Raffaella
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2008, 5116 : 711 - +
  • [23] Optimization of technique factors for a silicon diode array full-field digital mammography system and comparison to screen-film mammography with matched average glandular dose
    Berns, EA
    Hendrick, RE
    Cutter, GR
    [J]. MEDICAL PHYSICS, 2003, 30 (03) : 334 - 340
  • [24] PERFORMANCE COMPARISON OF SYSTEMS WITH FULL-FIELD DIGITAL MAMMOGRAPHY, DIGITAL BREAST TOMOSYNTHESIS AND CONTRAST-ENHANCED SPECTRAL MAMMOGRAPHY
    Avramova-Cholakova, Simona
    Kulama, Eugenia
    Daskalov, Sivo
    Loveland, John
    [J]. RADIATION PROTECTION DOSIMETRY, 2021, 197 (3-4) : 212 - 229
  • [25] Contrast Detail Phantom Comparison on a Commercially Available Unit. Digital Breast Tomosynthesis (DBT) versus Full-Field Digital Mammography (FFDM)
    Marco Bertolini
    Andrea Nitrosi
    Giovanni Borasi
    Andrea Botti
    Davide Tassoni
    Roberto Sghedoni
    Giulio Zuccoli
    [J]. Journal of Digital Imaging, 2011, 24 : 58 - 65
  • [26] Contrast Detail Phantom Comparison on a Commercially Available Unit. Digital Breast Tomosynthesis (DBT) versus Full-Field Digital Mammography (FFDM)
    Bertolini, Marco
    Nitrosi, Andrea
    Borasi, Giovanni
    Botti, Andrea
    Tassoni, Davide
    Sghedoni, Roberto
    Zuccoli, Giulio
    [J]. JOURNAL OF DIGITAL IMAGING, 2011, 24 (01) : 58 - 65
  • [27] Full-field digital mammography: Dose-dependant detectability of simulated breast lesions
    Obenauer, S
    Hermann, K
    Grabbe, EH
    [J]. RADIOLOGY, 2001, 221 : 189 - 189
  • [28] Full-field digital mammography: Dose-dependent detectability of simulated breast lesions
    Obenauer, S
    Hermann, KP
    Schorn, C
    Fischer, U
    Grabbe, E
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (12): : 1052 - 1056
  • [29] Optimizing full-field digital mammography techniques: The influence of target-filter and peak voltage settings on lesion detection and average glandular dose
    Hermann, KP
    Obenauer, S
    Funke, M
    Grabbe, E
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 108 - 110
  • [30] Combinations of Digital Breast Tomosynthesis and Full-field Digital Mammography for Different Density Types of Breasts
    Chen, Qiong
    Pan, Xin
    Xu, Junfeng
    Ying, Weifeng
    Hou, Yuyu
    Lu, Ming
    An, Dongqin
    Peng, Weijun
    [J]. CURRENT MEDICAL IMAGING, 2024, 20