The effect of tracheal tube size on air leak around the cuffs

被引:15
|
作者
Hwang, Jin-Young [1 ]
Park, Sang-Hyun [1 ]
Han, Sung-Hee [1 ]
Park, Seong-Joo [1 ]
Park, Soo-Kyung [2 ]
Kim, Jin-Hee [1 ]
机构
[1] Seoul Natl Univ, Bundang Hosp, Dept Anesthesiol & Pain Med, Seongnam, South Korea
[2] Seoul Natl Univ Hosp, Seoul, South Korea
关键词
Anesthesia; Intratracheal; Intubation;
D O I
10.4097/kjae.2011.61.1.24
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: This randomized single-blinded, cross-over study was done to evaluate the influence of the size of tracheal tubes on air leaks around the cuffs. Methods: In a benchtop model, the number of longitudinal folds on the cuffs was evaluated for different sizes of tracheal tubes. In an anesthetized patient study, thirty patients scheduled for elective surgery under general anesthesia were included. After induction of anesthesia, the trachea was intubated with two sizes of tracheal tubes in a random sequence: in men, internal diameter of 7.5 mm and 8.0 mm; in women, internal diameter of 7.0 mm and 7.5 mm. After tracheal intubation with each tube, air leak pressures were evaluated at intracuff pressures of 20, 25 and 30 cmH(2)O by auscultation. To calculate the tracheal tube resistance (R), an inspiratory pause of 20% was applied and the resulting peak airway pressure (P-peak), plateau pressure (P-pl) and mean expiratory tidal volume (Flow) were inserted in the formula R = (P-peak - P-pl)/Flow. Results: More longitudinal folds of the tracheal tube cuffs occurred in larger sized tubes compared to the smaller ones in a benchtop model. Air leakage was significantly less for the smaller tracheal tubes than for the larger ones for each gender at intracuff pressures of 20, 25 and 30 cmH(2)O. Tracheal tube resistances were not significantly altered by the size of tracheal tube. Conclusions: The use of a smaller tracheal tube within an acceptable size can reduce air leakage around the cuff without significantly changing the tracheal tube resistance.
引用
收藏
页码:24 / 29
页数:6
相关论文
共 50 条
  • [31] Automated cuff pressure regulators worsen tracheal sealing in HVLP tracheal tube cuffs
    Weiss, M.
    Doell, C.
    Madjdpour, C.
    Woitzek, K.
    Bernet, V
    SWISS MEDICAL WEEKLY, 2008, 138 (41-42) : 14S - 14S
  • [32] AIR VOLUME IN ENDOTRACHEAL-TUBE CUFFS
    CHANDER, S
    ANESTHESIOLOGY, 1980, 53 (05) : 437 - 437
  • [33] Respiratory mechanics during mechanical ventilation: A model study on the effects of leak around a tracheal tube
    Kondo, T
    Matsumoto, I
    Lanteri, CJ
    Sly, PD
    PEDIATRIC PULMONOLOGY, 1997, 24 (06) : 423 - 428
  • [34] THE PROGNOSTIC VALUE OF ENDOTRACHEAL TUBE-AIR LEAK FOLLOWING TRACHEAL SURGERY IN CHILDREN
    SEID, AB
    GODIN, MS
    PRANSKY, SM
    KEARNS, DB
    PETERSON, BM
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1991, 117 (08) : 880 - 882
  • [35] Fluid leakage past tracheal tube cuffs: evaluation of the new Microcuff endotracheal tube
    Alexander Dullenkopf
    Andreas Gerber
    Markus Weiss
    Intensive Care Medicine, 2003, 29 : 1849 - 1853
  • [36] Fluid leakage past tracheal tube cuffs: evaluation of the new Microcuff endotracheal tube
    Dullenkopf, A
    Gerber, A
    Weiss, M
    INTENSIVE CARE MEDICINE, 2003, 29 (10) : 1849 - 1853
  • [37] Interrupting gel layer between Double cuffs prevents fluid leakage past tracheal tube cuffs
    Hwang, J. Y.
    Han, S. H.
    Park, S. H.
    Park, S. J.
    Park, S.
    Oh, S. H.
    Kim, J. H.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 111 (03) : 496 - 504
  • [38] Pressures within air-filled tracheal cuffs at altitude
    Lowes, T
    ANAESTHESIA, 2004, 59 (09) : 919 - 920
  • [39] TRACHEAL TUBE LEAK TEST - IS THERE INTEROBSERVER AGREEMENT
    SCHWARTZ, RE
    STAYER, SA
    PASQUARIELLO, CA
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1993, 40 (11): : 1049 - 1052
  • [40] Clinical evaluation of stethoscope-guided inflation of tracheal tube cuffs
    Kumar, R. D. C.
    Hirsch, N. P.
    ANAESTHESIA, 2011, 66 (11) : 1012 - 1016