THE PROGNOSTIC VALUE OF ENDOTRACHEAL TUBE-AIR LEAK FOLLOWING TRACHEAL SURGERY IN CHILDREN

被引:0
|
作者
SEID, AB
GODIN, MS
PRANSKY, SM
KEARNS, DB
PETERSON, BM
机构
[1] CHILDRENS HOSP & HLTH CTR,DEPT OTOLARYNGOL,SAN DIEGO,CA
[2] CHILDRENS HOSP & HLTH CTR,DEPT CRIT CARE MED,SAN DIEGO,CA
[3] UNIV CALIF SAN DIEGO,MED CTR,DIV OTOLARYNGOL HEAD & NECK SURG,LA JOLLA,CA 92093
关键词
D O I
暂无
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
In an effort to determine if the endotracheal tube-leak pressure has prognostic value in relation to a successful outcome after one-stage laryngotracheal reconstruction or cricoid split surgery, a retrospective analysis was performed on 17 children who had undergone such surgery. The daily leak pressures, length of intubation, and ultimate outcome of attempts at extubation were noted. One hundred percent of patients with a leak pressure of less than 20 cm H2O on the day before extubation were successfully extubated. In contrast, the failure rate was 100% in children extubated with a leak of greater than 30 mm H2O. The difference between these two groups was statistically significant (chi-2, 13.03). Sixty percent of patients with leak pressures in the range of 21 to 30 cm H2O were successfully extubated. The endotracheal tube-leak pressure is a parameter that has prognostic value, and should be considered in determining when to extubate children who have undergone tracheal reconstructive surgery.
引用
收藏
页码:880 / 882
页数:3
相关论文
共 50 条
  • [1] Occult air leak of an endotracheal tube
    Tamakawa, S
    Sugawara, K
    Yanagita, Y
    Saito, Y
    ANESTHESIA AND ANALGESIA, 1998, 87 (03): : 746 - 746
  • [2] An unusual site of an occult air leak in an armoured endotracheal tube in the midst of surgery
    Kapoor, Dheeraj
    Singh, Amandeep
    INDIAN JOURNAL OF ANAESTHESIA, 2012, 56 (01) : 99 - +
  • [3] Acquired Tracheal Diverticulum as an Unexpected Cause of Endotracheal Tube Cuff Leak
    Agustin Flores-Franco, Rene
    Silva-Alcaraz, Jesus
    JOURNAL OF CRITICAL CARE MEDICINE, 2015, 1 (04): : 171 - 173
  • [4] ENDOTRACHEAL-TUBE LEAK PRESSURE AND TRACHEAL LUMEN SIZE IN SWINE
    FINHOLT, DA
    AUDENAERT, SM
    STIRT, JA
    MARCELLA, KL
    FRIERSON, HF
    SUDDARTH, LT
    RAPHAELY, RC
    ANESTHESIA AND ANALGESIA, 1986, 65 (06): : 667 - 671
  • [5] Endotracheal tube cuff leak during a cardiac surgery
    Munaf, Mamatha
    Gadhinglajkar, Shrinivas Vitthal
    Prakashbabu, U. Abinaya
    Satheesh, Sai Charan
    Radhakrishnan, Bineesh
    INDIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2024, 40 (04) : 516 - 518
  • [6] Persistent air leak with intact inflation system of endotracheal tube
    Khurana, Harneet Singh
    Singh, Tanveer
    Kundra, Sandeep
    Garg, Dinesh
    ANAESTHESIA PAIN & INTENSIVE CARE, 2024, 28 (02) : 395 - 396
  • [7] Predicting post-extubation stridor in children using the endotracheal tube air leak test
    Kim, HW
    Mink, RB
    CRITICAL CARE MEDICINE, 1999, 27 (12) : A55 - A55
  • [8] The "air leak" test around the endotracheal tube, as a predictor of postextubation stridor, is age dependent in children
    Mhanna, MJ
    Zamel, YB
    Tichy, CM
    Super, DM
    CRITICAL CARE MEDICINE, 2002, 30 (12) : 2639 - 2643
  • [9] Air leak from a tracheal tube after intubation: a review
    Cabrera, J. A.
    ANAESTHESIA, 2019, 74 (09) : 1194 - 1195
  • [10] The effect of tracheal tube size on air leak around the cuffs
    Hwang, Jin-Young
    Park, Sang-Hyun
    Han, Sung-Hee
    Park, Seong-Joo
    Park, Soo-Kyung
    Kim, Jin-Hee
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2011, 61 (01) : 24 - 29