The effect of tracheal tube size on air leak around the cuffs

被引:15
|
作者
Hwang, Jin-Young [1 ]
Park, Sang-Hyun [1 ]
Han, Sung-Hee [1 ]
Park, Seong-Joo [1 ]
Park, Soo-Kyung [2 ]
Kim, Jin-Hee [1 ]
机构
[1] Seoul Natl Univ, Bundang Hosp, Dept Anesthesiol & Pain Med, Seongnam, South Korea
[2] Seoul Natl Univ Hosp, Seoul, South Korea
关键词
Anesthesia; Intratracheal; Intubation;
D O I
10.4097/kjae.2011.61.1.24
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: This randomized single-blinded, cross-over study was done to evaluate the influence of the size of tracheal tubes on air leaks around the cuffs. Methods: In a benchtop model, the number of longitudinal folds on the cuffs was evaluated for different sizes of tracheal tubes. In an anesthetized patient study, thirty patients scheduled for elective surgery under general anesthesia were included. After induction of anesthesia, the trachea was intubated with two sizes of tracheal tubes in a random sequence: in men, internal diameter of 7.5 mm and 8.0 mm; in women, internal diameter of 7.0 mm and 7.5 mm. After tracheal intubation with each tube, air leak pressures were evaluated at intracuff pressures of 20, 25 and 30 cmH(2)O by auscultation. To calculate the tracheal tube resistance (R), an inspiratory pause of 20% was applied and the resulting peak airway pressure (P-peak), plateau pressure (P-pl) and mean expiratory tidal volume (Flow) were inserted in the formula R = (P-peak - P-pl)/Flow. Results: More longitudinal folds of the tracheal tube cuffs occurred in larger sized tubes compared to the smaller ones in a benchtop model. Air leakage was significantly less for the smaller tracheal tubes than for the larger ones for each gender at intracuff pressures of 20, 25 and 30 cmH(2)O. Tracheal tube resistances were not significantly altered by the size of tracheal tube. Conclusions: The use of a smaller tracheal tube within an acceptable size can reduce air leakage around the cuff without significantly changing the tracheal tube resistance.
引用
收藏
页码:24 / 29
页数:6
相关论文
共 50 条
  • [1] Air leakage around endotracheal tube cuffs
    Dullenkopf, A
    Schmitz, A
    Frei, M
    Gerber, AC
    Weiss, M
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 (06) : 448 - 453
  • [2] TRACHEAL TUBE CUFFS AND TRACHEAL DILATATION
    KING, K
    MANDAVA, B
    KAMEN, JM
    CHEST, 1975, 67 (04) : 458 - 462
  • [3] Leakage of fluid around low-pressure tracheal tube cuffs
    Oikkonen, M
    Aromaa, U
    ANAESTHESIA, 1997, 52 (06) : 567 - 569
  • [4] PRESSURES ON TRACHEAL TUBE CUFFS
    BRANDT, L
    ANAESTHESIA, 1982, 37 (05) : 597 - 598
  • [5] OVERINFLATION OF TRACHEAL TUBE CUFFS
    SMITH, AF
    ANAESTHESIA, 1995, 50 (01) : 84 - 84
  • [6] Nitrous oxide diffusion into tracheal tube cuffs: comparison of five different tracheal tube cuffs
    Dullenkopf, A
    Gerber, AC
    Weiss, M
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2004, 48 (09) : 1180 - 1184
  • [7] PRESSURES ON TRACHEAL TUBE CUFFS - REPLY
    BLACK, AMS
    SEEGOBIN, RD
    ANAESTHESIA, 1982, 37 (05) : 598 - 599
  • [8] PRESSURE CHANGES IN TRACHEAL TUBE CUFFS
    CHANDLER, M
    ANAESTHESIA, 1986, 41 (03) : 287 - 293
  • [9] Tapered tracheal tube cuffs are superior to cylindrical tracheal tube cuffs in preventing fluid leakage in different sized tracheas
    Dave, M. H.
    Koepfer, N.
    Madjapour, C.
    Frotzler, A.
    Weiss, M.
    SWISS MEDICAL WEEKLY, 2009, 139 (41-42) : 14S - 14S
  • [10] Air leak from a tracheal tube after intubation: a review
    Cabrera, J. A.
    ANAESTHESIA, 2019, 74 (09) : 1194 - 1195