Air leakage around endotracheal tube cuffs

被引:47
|
作者
Dullenkopf, A [1 ]
Schmitz, A [1 ]
Frei, M [1 ]
Gerber, AC [1 ]
Weiss, M [1 ]
机构
[1] Univ Childrens Hosp, Dept Anaesthesia, CH-8032 Zurich, Switzerland
关键词
anaesthesia; intubation; intratracheal; cuff;
D O I
10.1017/S0265021504006064
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and objective: To compare the recently introduced Microcuff(R) endotracheal tube with conventional tubes in respect of the cuff pressures required to prevent air leakage. Methods: The following tubes (ID 7.0 mm) were compared: Microcuff(R) HVLP ICU, Mallinckrodt HiLo(R), Portex Profile Soft Seal(R), Rusch Super Safety Clear(R) and Sheridan CF(R). Fifty patients undergoing endotracheal intubation with a cuffed tube of internal diameter 7.0 mm were studied. Tracheas were intubated using one of the endotracheal tubes in random order. Cuff pressure to prevent air leakage at standardized ventilator setting (peak inspiratory pressure 20 cmH(2)O/PEEP 5 cmH(2)O/respiratory rate 15 breaths min 1) was assessed by auscultation of audible sounds at the mouth. Patients characteristics and cuff pressures from each brand were compared to the Microcuff(R) group using the Mann-Whitney U-test (P < 0.05 was chosen as the level of statistical significance). Results: Patients' median age (range) was 14.2 (12.0-17.1) yr, body weight 57.5 (40.0-81.9) kg and length 164.9 (146.5-190.0) cm. No significant differences in patients' characteristics were found between groups. Mean cuff pressure (all tubes) required for air sealing was 19.1 (8-42) cmH(2)O. The Microcuff(C) tube required significantly lower sealing pressures (9.5 (8-12) cmH(2)O) compared to the other brands of enclotracheal tube (P < 0.05, Mann-Whitney U-test). Conclusion: The Microcuff(C) enclotracheal tube with its ultra-thin polyurethane cuff membrane required the lowest sealing pressure to prevent air leakage. These features are potentially of interest for long-term intubated patients and for cuffed enclotracheal tubes in children, allowing tracheal sealing at lower cuff pressures implying less damage to the trachea.
引用
收藏
页码:448 / 453
页数:6
相关论文
共 50 条
  • [1] Leakage of fluid around endotracheal tube cuffs: a cadaver study
    Birkenfeld, Falk
    Lucius, Ralph
    Ewald, Kristian
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2013, 65 (05) : 438 - 441
  • [2] AIR VOLUME IN ENDOTRACHEAL-TUBE CUFFS
    CHANDER, S
    ANESTHESIOLOGY, 1980, 53 (05) : 437 - 437
  • [3] Novel Endotracheal Tube Cuffs: Improving the Seal as a Barrier to Leakage
    Fisher, Daniel F.
    RESPIRATORY CARE, 2011, 56 (08) : 1213 - 1214
  • [4] FACTORS AFFECTING FLUID LEAKAGE PAST ENDOTRACHEAL TUBE CUFFS.
    Fisher, Daniel F.
    Pitts, Renee
    Jiang, Yandong
    Kacmarek, Robert M.
    CRITICAL CARE MEDICINE, 2008, 36 (12) : A138 - A138
  • [5] Variables affecting leakage past endotracheal tube cuffs: a bench study
    Pitts, Renee
    Fisher, Daniel
    Sulemanji, Demet
    Kratohvil, Joseph
    Jiang, Yandong
    Kacmarek, Robert
    INTENSIVE CARE MEDICINE, 2010, 36 (12) : 2066 - 2073
  • [6] Variables affecting leakage past endotracheal tube cuffs: a bench study
    Renée Pitts
    Daniel Fisher
    Demet Sulemanji
    Joseph Kratohvil
    Yandong Jiang
    Robert Kacmarek
    Intensive Care Medicine, 2010, 36 : 2066 - 2073
  • [7] Fluid leakage past tracheal tube cuffs: evaluation of the new Microcuff endotracheal tube
    Dullenkopf, A
    Gerber, A
    Weiss, M
    INTENSIVE CARE MEDICINE, 2003, 29 (10) : 1849 - 1853
  • [8] Fluid leakage past tracheal tube cuffs: evaluation of the new Microcuff endotracheal tube
    Alexander Dullenkopf
    Andreas Gerber
    Markus Weiss
    Intensive Care Medicine, 2003, 29 : 1849 - 1853
  • [9] COMPARISON OF FOAM AND AIR-FILLED ENDOTRACHEAL-TUBE CUFFS
    LEDERMAN, DS
    KLEIN, EF
    DRURY, WD
    DONNELLY, WH
    APPLEFELD, JJ
    CHAPMAN, RL
    DOWNS, JB
    ANESTHESIA AND ANALGESIA, 1974, 53 (04): : 521 - 526
  • [10] Leakage of fluid around low-pressure tracheal tube cuffs
    Oikkonen, M
    Aromaa, U
    ANAESTHESIA, 1997, 52 (06) : 567 - 569