The effect of tracheal tube size on air leak around the cuffs

被引:15
|
作者
Hwang, Jin-Young [1 ]
Park, Sang-Hyun [1 ]
Han, Sung-Hee [1 ]
Park, Seong-Joo [1 ]
Park, Soo-Kyung [2 ]
Kim, Jin-Hee [1 ]
机构
[1] Seoul Natl Univ, Bundang Hosp, Dept Anesthesiol & Pain Med, Seongnam, South Korea
[2] Seoul Natl Univ Hosp, Seoul, South Korea
关键词
Anesthesia; Intratracheal; Intubation;
D O I
10.4097/kjae.2011.61.1.24
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: This randomized single-blinded, cross-over study was done to evaluate the influence of the size of tracheal tubes on air leaks around the cuffs. Methods: In a benchtop model, the number of longitudinal folds on the cuffs was evaluated for different sizes of tracheal tubes. In an anesthetized patient study, thirty patients scheduled for elective surgery under general anesthesia were included. After induction of anesthesia, the trachea was intubated with two sizes of tracheal tubes in a random sequence: in men, internal diameter of 7.5 mm and 8.0 mm; in women, internal diameter of 7.0 mm and 7.5 mm. After tracheal intubation with each tube, air leak pressures were evaluated at intracuff pressures of 20, 25 and 30 cmH(2)O by auscultation. To calculate the tracheal tube resistance (R), an inspiratory pause of 20% was applied and the resulting peak airway pressure (P-peak), plateau pressure (P-pl) and mean expiratory tidal volume (Flow) were inserted in the formula R = (P-peak - P-pl)/Flow. Results: More longitudinal folds of the tracheal tube cuffs occurred in larger sized tubes compared to the smaller ones in a benchtop model. Air leakage was significantly less for the smaller tracheal tubes than for the larger ones for each gender at intracuff pressures of 20, 25 and 30 cmH(2)O. Tracheal tube resistances were not significantly altered by the size of tracheal tube. Conclusions: The use of a smaller tracheal tube within an acceptable size can reduce air leakage around the cuff without significantly changing the tracheal tube resistance.
引用
收藏
页码:24 / 29
页数:6
相关论文
共 50 条
  • [21] SURFACE ULTRASTRUCTURE AND PRESSURE DYNAMICS OF TRACHEAL TUBE CUFFS
    WU, WH
    ARTEAGA, M
    MLODOZENIEC, AR
    POPPERS, PJ
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1980, 14 (01): : 11 - 21
  • [22] Herniation of tracheal tube cuffs: a simple teaching model
    Wright, D
    Baruch, M
    ANAESTHESIA, 2001, 56 (03) : 277 - 277
  • [23] An in vitro study of the compliance of paediatric tracheal tube cuffs and tracheal wall pressure
    Bernet, V.
    Dullenkopf, A.
    Cannizzaro, V.
    Stutz, K.
    Weiss, M.
    ANAESTHESIA, 2006, 61 (10) : 978 - 983
  • [24] Effect of Lanz™ pressure regulating valve on self sealing mechanism and air leakage across the tracheal tube cuffs in a benchtop model
    Dave, Mital H.
    Spielmann, Nelly
    Mauch, Jacqueline
    Weiss, Markus
    SWISS MEDICAL WEEKLY, 2010, 140 : 14S - 14S
  • [25] Remote measurement of the leak around the uncuffed tracheal tube: objective measurement and physical characteristics
    Sims, A. J.
    Keltie, K.
    Reay, C. A.
    Smith, J. H.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 (01) : 152 - 158
  • [26] Absence or presence of a leak around tracheal tube may not affect postoperative croup in children
    Khalil, SN
    Mankarious, R
    Campos, C
    Chuang, AZ
    PAEDIATRIC ANAESTHESIA, 1998, 8 (05): : 393 - 396
  • [27] EFFECTS OF NITROUS-OXIDE ON PRESSURE CHANGES OF TRACHEAL TUBE CUFFS FOLLOWING INFLATION WITH AIR AND SALINE
    PATEL, RI
    OH, TH
    EPSTEIN, BS
    ANAESTHESIA, 1983, 38 (01) : 44 - 46
  • [28] PRESSURE AND VOLUME CHANGES IN TRACHEAL TUBE CUFFS DURING ANESTHESIA
    REVENAS, B
    LINDHOLM, CE
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1976, 20 (04) : 321 - 326
  • [29] INTENSIVE CARE NURSES′ KNOWLEDGE AND MANAGEMENT OF TRACHEAL TUBE CUFFS
    Labeau, S.
    Bleiman, M.
    Rello, J.
    Vandijck, D.
    Claes, B.
    Blot, S.
    INTENSIVE CARE MEDICINE, 2009, 35 : 203 - 203
  • [30] TRACHEAL WALL STRAIN FROM VARIOUS DEPRESSOR TUBE CUFFS
    SCHALK, HV
    REHAK, P
    ANAESTHESIST, 1985, 34 (03): : 158 - 159