Interrupting gel layer between Double cuffs prevents fluid leakage past tracheal tube cuffs

被引:9
|
作者
Hwang, J. Y. [1 ]
Han, S. H. [2 ]
Park, S. H. [2 ]
Park, S. J. [2 ]
Park, S. [2 ]
Oh, S. H. [3 ]
Kim, J. H. [2 ]
机构
[1] SMG SNU Boramae Med Ctr, Dept Anesthesiol & Pain Med, Seoul, South Korea
[2] Seoul Natl Univ, Bundang Hosp, Dept Anesthesiol & Pain Med, Gyeonggido, South Korea
[3] SMG SNU Boramae Med Ctr, Dept Biostat, Seoul, South Korea
关键词
cuffs tracheal; complications; equipment; respiratory aspiration; VENTILATOR-ASSOCIATED PNEUMONIA; LOW-PRESSURE CUFF; ENDOTRACHEAL-TUBES; HIGH-VOLUME; ASPIRATION; LUBRICATION; SHAPE;
D O I
10.1093/bja/aet152
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Current tracheal tubes (TTs) cannot guarantee a perfect seal against pulmonary aspiration of upper airway secretions. The purpose of this study was to investigate whether a gel layer between the tracheal tube with double cuffs (Double cuffs) prevents fluid leakage past TT cuffs. In vitro fluid leakage tests were performed using the Double cuff with or without a gel layer between the two cuffs and four commercially available TTs (Euromedical Standard TT, Mallinckrodt Hi-Lo, Microcuff, and Mallinckrodt TaperGuard) when placed in artificial tracheas with three-different internal diameters (ID; 16, 20, and 22 mm). Blue-dyed water (5 ml) was placed above the cuff, and the extent of fluid leakage was observed for 48 h. Each test was repeated five times with new tubes at six different intracuff pressures (15, 20, 25, 30, 40, and 50 cm H2O). In all of the conventional TTs and the Double cuff without a gel layer, fluid leakage was observed even at clinically acceptable intracuff pressures (2530 cm H2O). However, in the Double cuff with a gel layer, no fluid leakage was observed for 48 h at all intracuff pressures in three-different sized artificial tracheas. At an intracuff pressure of 20 cm H2O in a 20 mm ID trachea, the average volume of injected gel was 2.0 ml. After removal of the TT, the mean volume of the remaining gel in the trachea was 0.10 ml. A prototype TT with gel-layered Double cuffs completely blocked fluid leakage past the cuffs for 48 h in a bench-top model. Clinical studies are required to determine whether this TT reduces the risk of ventilator-associated pneumonia.
引用
收藏
页码:496 / 504
页数:9
相关论文
共 23 条
  • [1] Fluid leakage past tracheal tube cuffs: evaluation of the new Microcuff endotracheal tube
    Dullenkopf, A
    Gerber, A
    Weiss, M
    INTENSIVE CARE MEDICINE, 2003, 29 (10) : 1849 - 1853
  • [2] Fluid leakage past tracheal tube cuffs: evaluation of the new Microcuff endotracheal tube
    Alexander Dullenkopf
    Andreas Gerber
    Markus Weiss
    Intensive Care Medicine, 2003, 29 : 1849 - 1853
  • [3] Tapered tracheal tube cuffs are superior to cylindrical tracheal tube cuffs in preventing fluid leakage in different sized tracheas
    Dave, M. H.
    Koepfer, N.
    Madjapour, C.
    Frotzler, A.
    Weiss, M.
    SWISS MEDICAL WEEKLY, 2009, 139 (41-42) : 14S - 14S
  • [4] Leakage of fluid around low-pressure tracheal tube cuffs
    Oikkonen, M
    Aromaa, U
    ANAESTHESIA, 1997, 52 (06) : 567 - 569
  • [5] FACTORS AFFECTING FLUID LEAKAGE PAST ENDOTRACHEAL TUBE CUFFS.
    Fisher, Daniel F.
    Pitts, Renee
    Jiang, Yandong
    Kacmarek, Robert M.
    CRITICAL CARE MEDICINE, 2008, 36 (12) : A138 - A138
  • [6] FLUID LEAKAGE PAST TRACHEAL TUBE CUFFS: EFFECT OF SUCTIONING MANOEUVRE AND TYPE OF CUFF IN A BENCHTOP MODEL
    Beuret, P.
    Carton, M. -J.
    Kaaki, M.
    Fabre, X.
    Ducreux, J. -C.
    INTENSIVE CARE MEDICINE, 2009, 35 : 219 - 219
  • [7] Leakage of fluid around endotracheal tube cuffs: a cadaver study
    Birkenfeld, Falk
    Lucius, Ralph
    Ewald, Kristian
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2013, 65 (05) : 438 - 441
  • [8] Aspiration past tracheal cuffs of double lumen endobronchial tubes (DLEBT) - effect of gel lubrication
    Sanjay, PS
    Miller, SA
    Corry, PR
    Russell, GN
    Pennefather, SH
    BRITISH JOURNAL OF ANAESTHESIA, 2004, 93 (01) : 160P - 160P
  • [9] Variables affecting leakage past endotracheal tube cuffs: a bench study
    Pitts, Renee
    Fisher, Daniel
    Sulemanji, Demet
    Kratohvil, Joseph
    Jiang, Yandong
    Kacmarek, Robert
    INTENSIVE CARE MEDICINE, 2010, 36 (12) : 2066 - 2073
  • [10] Variables affecting leakage past endotracheal tube cuffs: a bench study
    Renée Pitts
    Daniel Fisher
    Demet Sulemanji
    Joseph Kratohvil
    Yandong Jiang
    Robert Kacmarek
    Intensive Care Medicine, 2010, 36 : 2066 - 2073