Interrupting gel layer between Double cuffs prevents fluid leakage past tracheal tube cuffs

被引:9
|
作者
Hwang, J. Y. [1 ]
Han, S. H. [2 ]
Park, S. H. [2 ]
Park, S. J. [2 ]
Park, S. [2 ]
Oh, S. H. [3 ]
Kim, J. H. [2 ]
机构
[1] SMG SNU Boramae Med Ctr, Dept Anesthesiol & Pain Med, Seoul, South Korea
[2] Seoul Natl Univ, Bundang Hosp, Dept Anesthesiol & Pain Med, Gyeonggido, South Korea
[3] SMG SNU Boramae Med Ctr, Dept Biostat, Seoul, South Korea
关键词
cuffs tracheal; complications; equipment; respiratory aspiration; VENTILATOR-ASSOCIATED PNEUMONIA; LOW-PRESSURE CUFF; ENDOTRACHEAL-TUBES; HIGH-VOLUME; ASPIRATION; LUBRICATION; SHAPE;
D O I
10.1093/bja/aet152
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Current tracheal tubes (TTs) cannot guarantee a perfect seal against pulmonary aspiration of upper airway secretions. The purpose of this study was to investigate whether a gel layer between the tracheal tube with double cuffs (Double cuffs) prevents fluid leakage past TT cuffs. In vitro fluid leakage tests were performed using the Double cuff with or without a gel layer between the two cuffs and four commercially available TTs (Euromedical Standard TT, Mallinckrodt Hi-Lo, Microcuff, and Mallinckrodt TaperGuard) when placed in artificial tracheas with three-different internal diameters (ID; 16, 20, and 22 mm). Blue-dyed water (5 ml) was placed above the cuff, and the extent of fluid leakage was observed for 48 h. Each test was repeated five times with new tubes at six different intracuff pressures (15, 20, 25, 30, 40, and 50 cm H2O). In all of the conventional TTs and the Double cuff without a gel layer, fluid leakage was observed even at clinically acceptable intracuff pressures (2530 cm H2O). However, in the Double cuff with a gel layer, no fluid leakage was observed for 48 h at all intracuff pressures in three-different sized artificial tracheas. At an intracuff pressure of 20 cm H2O in a 20 mm ID trachea, the average volume of injected gel was 2.0 ml. After removal of the TT, the mean volume of the remaining gel in the trachea was 0.10 ml. A prototype TT with gel-layered Double cuffs completely blocked fluid leakage past the cuffs for 48 h in a bench-top model. Clinical studies are required to determine whether this TT reduces the risk of ventilator-associated pneumonia.
引用
收藏
页码:496 / 504
页数:9
相关论文
共 23 条
  • [11] Aspiration past bronchial cuffs of double lumen endobronchial tubes (DLEBT): effect of gel lubrication
    Sridhar, H.
    Al Rawi, O.
    Dave, I.
    Desilva, S.
    Russell, G. N.
    Pennefather, S. H.
    BRITISH JOURNAL OF ANAESTHESIA, 2007, 99 (05) : 754P - 754P
  • [12] Leakage of fluid around high-volume, low-pressure cuffs - A comparison of four tracheal tubes
    Asai, T
    Shingu, K
    ANAESTHESIA, 2001, 56 (01) : 38 - 42
  • [13] Leakage of fluid past the tracheal tube cuff in a benchtop model
    Young, PJ
    Rollinson, M
    Downward, G
    Henderson, S
    BRITISH JOURNAL OF ANAESTHESIA, 1997, 78 (05) : 557 - 562
  • [14] Effect of Lanz™ pressure regulating valve on self sealing mechanism and air leakage across the tracheal tube cuffs in a benchtop model
    Dave, Mital H.
    Spielmann, Nelly
    Mauch, Jacqueline
    Weiss, Markus
    SWISS MEDICAL WEEKLY, 2010, 140 : 14S - 14S
  • [15] Effect of closed tracheal suction system on fluid leakage past the tracheal tube cuff
    Dave, M. H.
    Koepfer, N.
    Madjdpour, C.
    Frotzler, A.
    Weiss, M.
    SWISS MEDICAL WEEKLY, 2009, 139 (41-42) : 14S - 15S
  • [16] An In Vitro Study to Assess Determinant Features Associated With Fluid Sealing in the Design of Endotracheal Tube Cuffs and Exerted Tracheal Pressures
    Bassi, Gianluigi Li
    Ranzani, Otavio Tavares
    Marti, Joan Daniel
    Giunta, Valeria
    Luque, Nestor
    Isetta, Valentina
    Ferrer, Miquel
    Farre, Ramon
    Pimentel, Guilherme Leite
    Torres, Antoni
    CRITICAL CARE MEDICINE, 2013, 41 (02) : 518 - 526
  • [17] Comparison of fluid leakage across endotracheal tube cuffs using a three-dimensional printed model of the human trachea
    Kimijima, Tomohiko
    Edanaga, Mitsutaka
    Yamakage, Michiaki
    JOURNAL OF ANESTHESIA, 2016, 30 (03) : 510 - 513
  • [18] Comparison of fluid leakage across endotracheal tube cuffs using a three-dimensional printed model of the human trachea
    Tomohiko Kimijima
    Mitsutaka Edanaga
    Michiaki Yamakage
    Journal of Anesthesia, 2016, 30 : 510 - 513
  • [19] Mechanical influences on fluid leakage past the tracheal tube cuff in a benchtop model
    Ouanes, Islem
    Lyazidi, Aissam
    Danin, Pierre Eric
    Rana, Nerlep
    Di Bari, Annalisa
    Abroug, Fekri
    Louis, Bruno
    Brochard, Laurent
    INTENSIVE CARE MEDICINE, 2011, 37 (04) : 695 - 700
  • [20] Mechanical influences on fluid leakage past the tracheal tube cuff in a benchtop model
    Islem Ouanes
    Aissam Lyazidi
    Pierre Eric Danin
    Nerlep Rana
    Annalisa Di Bari
    Fekri Abroug
    Bruno Louis
    Laurent Brochard
    Intensive Care Medicine, 2011, 37 : 695 - 700